Measuring orientation of human body segments using miniature gyroscopes and accelerometers.

H J Luinge1, P H Veltink.   

Abstract

In the medical field, there is a need for small ambulatory sensor systems for measuring the kinematics of body segments. Current methods for ambulatory measurement of body orientation have limited accuracy when the body moves. The aim of the paper was to develop and validate a method for accurate measurement of the orientation of human body segments using an inertial measurement unit (IMU). An IMU containing three single-axis accelerometers and three single-axis micromachined gyroscopes was assembled in a rectangular box, sized 20 x 20 x 30 mm. The presented orientation estimation algorithm continuously corrected orientation estimates obtained by mathematical integration of the 3D angular velocity measured using the gyroscopes. The correction was performed using an inclination estimate continuously obtained using the signal of the 3D accelerometer. This reduces the integration drift that originates from errors in the angular velocity signal. In addition, the gyroscope offset was continuously recalibrated. The method was realised using a Kalman filter that took into account the spectra of the signals involved as well as a fluctuating gyroscope offset. The method was tested for movements of the pelvis, trunk and forearm. Although the problem of integration drift around the global vertical continuously increased in the order of 0.50 degrees s(-1), the inclination estimate was accurate within 3 degrees RMS. It was shown that the gyroscope offset could be estimated continuously during a trial. Using an initial offset error of 1 rad s(-1), after 2 min the off-set error was roughly 5% of the original offset error. Using the Kalman filter described, an accurate and robust system for ambulatory motion recording can be realised.

Entities:  

Mesh:

Year:  2005        PMID: 15865139     DOI: 10.1007/bf02345966

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  26 in total

1.  Sensor systems for lower limb functional electrical stimulation (FES) control.

Authors:  R Williamson; B J Andrews
Journal:  Med Eng Phys       Date:  2000-06       Impact factor: 2.242

2.  A reliable gait phase detection system.

Authors:  I P Pappas; M R Popovic; T Keller; V Dietz; M Morari
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2001-06       Impact factor: 3.802

3.  Assessment of inertial and gravitational inputs to the vestibular system.

Authors:  G Baselli; G Legnani; P Franco; F Brognoli; A Marras; F Quaranta; B Zappa
Journal:  J Biomech       Date:  2001-06       Impact factor: 2.712

4.  Detecting absolute human knee angle and angular velocity using accelerometers and rate gyroscopes.

Authors:  R Williamson; B J Andrews
Journal:  Med Biol Eng Comput       Date:  2001-05       Impact factor: 2.602

5.  Accelerometer and rate gyroscope measurement of kinematics: an inexpensive alternative to optical motion analysis systems.

Authors:  Ruth E Mayagoitia; Anand V Nene; Peter H Veltink
Journal:  J Biomech       Date:  2002-04       Impact factor: 2.712

6.  Detection of daily physical activities using a triaxial accelerometer.

Authors:  M J Mathie; A C F Coster; N H Lovell; B G Celler
Journal:  Med Biol Eng Comput       Date:  2003-05       Impact factor: 2.602

7.  Body position can be monitored in 3D using miniature accelerometers and earth-magnetic field sensors.

Authors:  B Kemp; A J Janssen; B van der Kamp
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1998-12

8.  A method for inverse dynamic analysis using accelerometry.

Authors:  A van den Bogert; L Read; B M Nigg
Journal:  J Biomech       Date:  1996-07       Impact factor: 2.712

9.  Long-term unrestrained measurement of stride length and walking velocity utilizing a piezoelectric gyroscope.

Authors:  S Miyazaki
Journal:  IEEE Trans Biomed Eng       Date:  1997-08       Impact factor: 4.538

10.  A practical gait analysis system using gyroscopes.

Authors:  K Tong; M H Granat
Journal:  Med Eng Phys       Date:  1999-03       Impact factor: 2.242

View more
  88 in total

1.  A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion states.

Authors:  Jong Yong A Foo; Stephen J Wilson
Journal:  Med Biol Eng Comput       Date:  2006-03       Impact factor: 2.602

2.  Development of a real-time three-dimensional spinal motion measurement system for clinical practice.

Authors:  Christina Goodvin; Edward J Park; Kevin Huang; Kelly Sakaki
Journal:  Med Biol Eng Comput       Date:  2006-11-11       Impact factor: 2.602

3.  An interactive Internet-based system for tracking upper limb motion in home-based rehabilitation.

Authors:  Shumei Zhang; Huosheng Hu; Huiyu Zhou
Journal:  Med Biol Eng Comput       Date:  2007-12-18       Impact factor: 2.602

4.  Support vector machine for classification of walking conditions using miniature kinematic sensors.

Authors:  Hong-Yin Lau; Kai-Yu Tong; Hailong Zhu
Journal:  Med Biol Eng Comput       Date:  2008-03-18       Impact factor: 2.602

5.  An enactive approach to appropriation in the instrumented activity of trail running.

Authors:  Nadège Rochat; Ludovic Seifert; Brice Guignard; Denis Hauw
Journal:  Cogn Process       Date:  2019-06-01

6.  Inertial and time-of-arrival ranging sensor fusion.

Authors:  Paul Vasilyev; Sean Pearson; Mahmoud El-Gohary; Mateo Aboy; James McNames
Journal:  Gait Posture       Date:  2017-02-20       Impact factor: 2.840

7.  Estimation of Attitude and External Acceleration Using Inertial Sensor Measurement During Various Dynamic Conditions.

Authors:  Jung Keun Lee; Edward J Park; Stephen N Robinovitch
Journal:  IEEE Trans Instrum Meas       Date:  2012-01-08       Impact factor: 4.016

8.  Two linear regression models predicting cumulative dynamic L5/S1 joint moment during a range of lifting tasks based on static postures.

Authors:  Xu Xu; Chien-Chi Chang; Ming-Lun Lu
Journal:  Ergonomics       Date:  2012-07-17       Impact factor: 2.778

9.  Trunk angular kinematics during slip-induced backward falls and activities of daily living.

Authors:  Jian Liu; Thurmon E Lockhart
Journal:  J Biomech Eng       Date:  2014-10       Impact factor: 2.097

10.  Ambulatory human motion tracking by fusion of inertial and magnetic sensing with adaptive actuation.

Authors:  H Martin Schepers; Daniel Roetenberg; Peter H Veltink
Journal:  Med Biol Eng Comput       Date:  2009-12-17       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.