High wear rates and extensive osteolysis in 3 types of uncemented total hip arthroplasty: a review of the PCA, the Harris Galante and the Profile/Tri-Lock Plus arthroplasties with a minimum of 12 years median follow-up in 96 hips.

Geir Hallan1, Stein A Lie, Leif I Havelin.   

Abstract

BACKGROUND: High wear rates and femoral and acetabular osteolysis have been-and still are-the main problems in uncemented total hip replacement. We reviewed 96 consecutive cementless total hip replacements of 4 different designs. PATIENTS AND METHODS: 21 PCA, 25 Harris Galante Porous/Harris Galante I (stem/cup), 25 Profile pressfit/ Tri-Lock Plus (stem/cup) and 25 Profile HA-coated/Tri-Lock Plus (stem/cup) prostheses were included. The operations were performed in the period 1984-1991. Median follow-up ranged from 12-16 years. Wear and osteolysis were measured.
RESULTS: Mean linear wear rates ranged from 0.17 to 0.21 mm/year in the 4 groups, and there were no statistically significant differences between the groups (p = 0.9, ANOVA). Moderate or extensive osteolysis was found in 46 of the 96 hips included. The association between high and low wear rates (more or less than 0.20 mm/ year) and extent of osteolysis was statistically significant (p < 0.001, t-test). We found poor 12-year survival of the primary prostheses in all 4 groups (50-70%), mainly due to revisions because of wear of the polyethylene liner and/or osteolysis. The infrequently documented Profile/Tri-Lock Plus systems did not perform differently from the PCA and the HG.
INTERPRETATION: The poor long-term results with these uncemented total hip arthroplasties illustrate the necessity of regular radiographic evaluation in order to detect osteolysis and liner failure, which are both generally asymptomatic until catastrophic failure appears.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16929433     DOI: 10.1080/17453670610012638

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


  20 in total

1.  Is routine mid-term total hip arthroplasty surveillance beneficial?

Authors:  James A Keeney; Bradley S Ellison; William J Maloney; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2012-06-06       Impact factor: 4.176

2.  CORR Insights(®): Backside Wear Is Not Dependent on the Acetabular Socket Design in Crosslinked Polyethylene Liners.

Authors:  Christophe Nich
Journal:  Clin Orthop Relat Res       Date:  2015-08-11       Impact factor: 4.176

3.  Porous titanium construct cup compared to porous coated titanium cup in total hip arthroplasty. A randomised controlled trial.

Authors:  Mats Salemyr; Olle Muren; Thomas Eisler; Henrik Bodén; Ghazi Chammout; André Stark; Olof Sköldenberg
Journal:  Int Orthop       Date:  2014-10-22       Impact factor: 3.075

4.  Metal-on-conventional polyethylene total hip arthroplasty bearing surfaces have a higher risk of revision than metal-on-highly crosslinked polyethylene: results from a US registry.

Authors:  Elizabeth W Paxton; Maria C S Inacio; Robert S Namba; Rebecca Love; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

5.  Vitamin-E diffused highly cross-linked polyethylene liner compared to standard liners in total hip arthroplasty. A randomized, controlled trial.

Authors:  Mats Salemyr; Olle Muren; Torbjörn Ahl; Henrik Bodén; Ghazi Chammout; André Stark; Olof Sköldenberg
Journal:  Int Orthop       Date:  2015-01-29       Impact factor: 3.075

Review 6.  Is there evidence for accelerated polyethylene wear in uncemented compared to cemented acetabular components? A systematic review of the literature.

Authors:  Hugo C van der Veen; Hans-Peter W van Jonbergen; Rudolf W Poolman; Sjoerd K Bulstra; Jos J A M van Raay
Journal:  Int Orthop       Date:  2012-12-11       Impact factor: 3.075

7.  Polyethylene in total hip arthroplasty: half a century in the limelight.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo
Journal:  J Orthop Traumatol       Date:  2010-05-27

8.  Bone mineral density of the femoral neck in resurfacing hip arthroplasty.

Authors:  Jeannette Østergaard Penny; Ole Ovesen; Kim Brixen; Jens-Erik Varmarken; Søren Overgaard
Journal:  Acta Orthop       Date:  2010-06       Impact factor: 3.717

9.  Minimal stress shielding with a Mallory-Head titanium femoral stem with proximal porous coating in total hip arthroplasty.

Authors:  Brad Ellison; Nicholas A Cheney; Keith R Berend; Adolph V Lombardi; Thomas H Mallory
Journal:  J Orthop Surg Res       Date:  2009-12-09       Impact factor: 2.359

10.  Increased risk of revision of acetabular cups coated with hydroxyapatite.

Authors:  Stergios Lazarinis; Johan Kärrholm; Nils P Hailer
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.