Long-term absorption of poly-L-lactic Acid interference screws.

F Alan Barber1, W Dee Dockery.   

Abstract

PURPOSE: To evaluate the long term in vivo degradation of poly-L-lactic acid (PLLA) interference screws with computed tomography (CT) and radiography as used in patellar tendon autograft anterior cruciate ligament (ACL) reconstruction.
METHODS: A total of 20 patients who had undergone patellar tendon autograft ACL reconstruction fixed with PLLA screws at least 7 years earlier were evaluated by physical examination, radiography, and CT to determine whether PLLA screw reabsorption and bone ingrowth had occurred. This study was granted Institutional Review Board approval. Lysholm, Tegner, Cincinnati, and International Knee Documentation Committee (IKDC) scores were obtained. CT data were measured in Hounsfield units.
RESULTS: In all, 15 men and 5 women were evaluated 104 months after surgery (range, 89 to 124 months). CT and radiography demonstrated that the bone plug had fused to the tunnel wall, and that no intact interference screw was left. A parallel, threaded, and corticated screw tract was visible adjacent to the bone plug. No bone ingrowth had occurred at the screw site, although, occasionally, minimal calcification was seen. This was never as dense as cancellous bone, and no trabeculae were ever present. No positive pivot-shift test results were obtained. Lysholm, Tegner, and Cincinnati scores were 83, 5.6, and 75, respectively, at follow-up. Average KT difference was 0.7 mm. DISCUSSION: PLLA interference screws completely degraded, and the resulting area demonstrated a low Hounsfield count, consistent with soft tissue 7 years after insertion. No significant bone ingrowth occurred at the screw site. Femoral and tibial ACL tunnels were absent of anything but fibrous tissue and usually had a sclerotic cortical lining.
CONCLUSION: PLLA biodegradable ACL screws eventually disappear completely. PLLA material is not replaced by bone. ACL graft tunnels are filled with nonossified material. This study provides a baseline for comparison with other biodegradable interference screws that may encourage bone ingrowth as they degrade. LEVEL OF EVIDENCE: Level IV (no or historical control).

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16904577     DOI: 10.1016/j.arthro.2006.04.096

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  30 in total

1.  Anterior cruciate ligament reconstruction using biodegradable transfemoral fixation at 5-year follow-up: clinical and magnetic resonance imaging evaluation.

Authors:  Sven Nebelung; Gregor Deitmer; Rolf Gebing; Frank Reichwein; Wolfgang Nebelung
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-06       Impact factor: 4.342

2.  Poly-L-lactic acid - hydroxyapatite (PLLA-HA) bioabsorbable interference screws for tibial graft fixation in anterior cruciate ligament (ACL) reconstruction surgery: MR evaluation of osteointegration and degradation features.

Authors:  L Macarini; P Milillo; A Mocci; R Vinci; G C Ettorre
Journal:  Radiol Med       Date:  2008-10-25       Impact factor: 3.469

3.  Comparison of the bioabsorbable and metal screw fixation after ACL reconstruction with a hamstring autograft in MRI and clinical outcome: a prospective randomized study.

Authors:  Anna-Stina Moisala; Timo Järvelä; Antti Paakkala; Timo Paakkala; Pekka Kannus; Markku Järvinen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-09-02       Impact factor: 4.342

4.  Polymer-hydroxyapatite composite versus polymer interference screws in anterior cruciate ligament reconstruction in a large animal model.

Authors:  John A Hunt; Jill T Callaghan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-04-17       Impact factor: 4.342

5.  A Comparison of Functional Outcomes After Metallic and Bioabsorbable Interference Screw Fixations in Arthroscopic ACL Reconstructions.

Authors:  Atmananda S Hegde; Deepak K Rai; Antony J Kannampilly
Journal:  J Clin Diagn Res       Date:  2014-04-15

6.  Arthroscopic double-row repair of the rotator cuff: a comparison of bio-absorbable and non-resorbable anchors regarding osseous reaction.

Authors:  Hendrik Haneveld; Konstantin Hug; Gerd Diederichs; Markus Scheibel; Christian Gerhardt
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-21       Impact factor: 4.342

7.  Do newer-generation bioabsorbable screws become incorporated into bone at two years after ACL reconstruction with patellar tendon graft?: A cohort study.

Authors:  Charles L Cox; Kurt P Spindler; James P Leonard; Brent J Morris; Warren R Dunn; Emily K Reinke
Journal:  J Bone Joint Surg Am       Date:  2014-02-05       Impact factor: 5.284

8.  The effect of patient and injury factors on long-term outcome after anterior cruciate ligament reconstruction.

Authors:  Robert A Magnussen; Kurt P Spindler
Journal:  Curr Orthop Pract       Date:  2011-01-01

9.  Magnetic resonance imaging analysis of the bioabsorbable Milagro interference screw for graft fixation in anterior cruciate ligament reconstruction.

Authors:  K-H Frosch; T Sawallich; G Schütze; A Losch; T Walde; P Balcarek; F Konietschke; K M Stürmer
Journal:  Strategies Trauma Limb Reconstr       Date:  2009-08-21

10.  A biodegradable antibiotic delivery system based on poly-(trimethylene carbonate) for the treatment of osteomyelitis.

Authors:  Daniëlle Neut; Otto S Kluin; Bart J Crielaard; Henny C van der Mei; Henk J Busscher; Dirk W Grijpma
Journal:  Acta Orthop       Date:  2009-10       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.