Abstract

INTRODUCTION: Anterior Cruciate Ligament (ACL) is as one of the most frequently injured ligaments in the modern contact sports scenario. Graft fixations can be achieved during anterior cruciate ligament (ACL) reconstructions by using either bioabsorbable screws or metal screws. The objective of this study was to compare the functional outcomes after bioabsorbable and metallic interference screw fixations in arthroscopic anterior cruciate ligament reconstructions done by using hamstring grafts.
MATERIALS AND METHODS: This was a prospective, randomized study. Patients in Group 1 received bioabsorbable interference screws and patients in Group 2 received metallic interference screws. Arthroscopic assisted, anterior cruciate ligament reconstructions with the use of hamstring grafts which were fixed proximally with endobuttons and distally with bioabsorbable or metallic interference screws, were undertaken. Progress in functional outcomes was assessed by using Mann Whitney U- test. Functional outcomes in the two groups were compared by using independent t-test. OBSERVATION AND
RESULTS: In each group, there were statistically significant improvements in functional outcomes over successive follow-ups, which were seen on basis on Mann-Whitney U-test. The comparison of functional outcomes between the two groups, done by using independent t-test, showed no statistically significant differences between the two groups at 3 months, 6 months and 1 year of follow-up. p-value <0.05 was considered to be significant in our study.
CONCLUSION: In our prospective study of comparison of functional outcomes between bioabsorbable and metallic interference screws in arthroscopic anterior cruciate ligament reconstuctions, which were evaluated by using Tegner activity scale and Lysholm knee scoring scale for a period of 1 year, no statistically significant difference was found. However, further authentication is required by doing long term studies.

Entities:  

Keywords:  ACL reconstruction; Bioabsorbable and Metallic interference screws

Year:  2014        PMID: 24959468      PMCID: PMC4064890          DOI: 10.7860/JCDR/2014/8834.4237

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  20 in total

1.  Bioscrew fixation of patellar tendon autografts.

Authors:  F A Barber; B F Elrod; D A McGuire; L E Paulos
Journal:  Biomaterials       Date:  2000-12       Impact factor: 12.479

2.  Practical considerations in anterior cruciate ligament replacement surgery.

Authors:  M S Fineberg; B Zarins; O H Sherman
Journal:  Arthroscopy       Date:  2000-10       Impact factor: 4.772

3.  Anterior cruciate ligament reconstruction with bioabsorbable polyglycolic acid interference screws: MR imaging follow-up.

Authors:  Fabienne D Bach; Robert Y Carlier; Jean B Elis; Dominique M Mompoint; Antoine Feydy; Olivia Judet; Philippe Beaufils; Christian Vallée
Journal:  Radiology       Date:  2002-11       Impact factor: 11.105

Review 4.  The science of reconstruction of the anterior cruciate ligament.

Authors:  C B Frank; D W Jackson
Journal:  J Bone Joint Surg Am       Date:  1997-10       Impact factor: 5.284

5.  Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers.

Authors:  O Böstman; E Hirvensalo; J Mäkinen; P Rokkanen
Journal:  J Bone Joint Surg Br       Date:  1990-07

Review 6.  Bioabsorbable versus metallic interference screw fixation in anterior cruciate ligament reconstruction: a meta-analysis of randomized controlled trials.

Authors:  Chao Shen; Sheng-Dan Jiang; Lei-Sheng Jiang; Li-Yang Dai
Journal:  Arthroscopy       Date:  2010-05       Impact factor: 4.772

7.  Preliminary results of an absorbable interference screw.

Authors:  F A Barber; B F Elrod; D A McGuire; L E Paulos
Journal:  Arthroscopy       Date:  1995-10       Impact factor: 4.772

Review 8.  Adverse tissue reactions to bioabsorbable fixation devices.

Authors:  O M Böstman; H K Pihlajamäki
Journal:  Clin Orthop Relat Res       Date:  2000-02       Impact factor: 4.176

9.  Bilok interference screws for anterior cruciate ligament reconstruction: clinical and radiographic outcomes.

Authors:  F Alan Barber; Michael H Boothby
Journal:  Arthroscopy       Date:  2007-05       Impact factor: 4.772

10.  Biomechanics and anterior cruciate ligament reconstruction.

Authors:  Savio L-Y Woo; Changfu Wu; Ozgur Dede; Fabio Vercillo; Sabrina Noorani
Journal:  J Orthop Surg Res       Date:  2006-09-25       Impact factor: 2.359

View more
  5 in total

1.  Resorbable screw and sheath versus resorbable interference screw and staples for ACL reconstruction: a comparison of two tibial fixation methods.

Authors:  Christian Carulli; Fabrizio Matassi; Stefano Soderi; Luigi Sirleo; Giovanni Munz; Massimo Innocenti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-27       Impact factor: 4.342

Review 2.  Comparison of Bioabsorbable and Metallic Interference Screws for Graft Fixation During ACL Reconstruction: A Meta-analysis of Randomized Controlled Trials.

Authors:  Baoyun Xu; Yuling Yin; Yanling Zhu; Yu Yin; Weili Fu
Journal:  Orthop J Sports Med       Date:  2021-08-18

Review 3.  Bioabsorbable versus metallic interference screws for graft fixation in anterior cruciate ligament reconstruction.

Authors:  Pedro Debieux; Carlos E S Franciozi; Mário Lenza; Marcel Jun Tamaoki; Robert A Magnussen; Flávio Faloppa; João Carlos Belloti
Journal:  Cochrane Database Syst Rev       Date:  2016-07-24

4.  Computed Tomography Imaging of BioComposite Interference Screw After ACL Reconstruction With Bone-Patellar Tendon-Bone Graft.

Authors:  Brian Scrivens; Melissa A Kluczynski; Marc S Fineberg; Leslie J Bisson
Journal:  Orthop J Sports Med       Date:  2021-05-06

Review 5.  A comprehensive scoping review of tibial cysts after anterior cruciate ligament reconstruction.

Authors:  Nuno Camelo Barbosa; João Pedro Campos; Vânia Capelão; Vikram Kandhari; Thais Dutra Vieira; Bertrand Sonnery-Cottet
Journal:  J Exp Orthop       Date:  2021-06-21
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.