Literature DB >> 16872081

Properties of unflattened photon beams shaped by a multileaf collimator.

Falk Pönisch1, Uwe Titt, Oleg N Vassiliev, Stephen F Kry, Radhe Mohan.   

Abstract

Several studies have shown that removal of the flattening filter from the treatment head of a clinical accelerator increases the dose rate and changes the lateral profile in radiation therapy with photons. However, the multileaf collimator (MLC) used to shape the field was not taken into consideration in these studies. We therefore investigated the effect of the MLC on flattened and unflattened beams. To do this, we performed measurements on a Varian Clinac 21EX and MCNPX Monte Carlo simulations to analyze the physical properties of the photon beam. We compared lateral profiles, depth dose curves, MLC leakages, and total scatter factors for two energies (6 and 18 MV) of MLC-shaped fields and jaw-shaped fields. Our study showed that flattening filter-free beams shaped by a MLC differ from the jaw-shaped beams. Similar differences were also observed for flattened beams. Although both collimating methods produced identical depth dose curves, the penumbra size and the MLC leakage were reduced in the softer, unflattened beam and the total scatter factors showed a smaller field size dependence.

Mesh:

Year:  2006        PMID: 16872081     DOI: 10.1118/1.2201149

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  49 in total

1.  Dosimetric properties of a flattening filter-free 6-MV photon beam: a Monte Carlo study.

Authors:  Asghar Mesbahi; Parinaz Mehnati; Ahmad Keshtkar; Alireza Farajollahi
Journal:  Radiat Med       Date:  2007-08-27

2.  Monte Carlo study on a flattening filter-free 18-MV photon beam of a medical linear accelerator.

Authors:  Asghar Mesbahi; Farshad Seyed Nejad
Journal:  Radiat Med       Date:  2008-08-03

3.  Multisource modeling of flattening filter free (FFF) beam and the optimization of model parameters.

Authors:  Woong Cho; Kayla N Kielar; Ed Mok; Lei Xing; Jeong-Hoon Park; Won-Gyun Jung; Tae-Suk Suh
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

4.  Inverse planning for IMRT with nonuniform beam profiles using total-variation regularization (TVR).

Authors:  Taeho Kim; Lei Zhu; Tae-Suk Suh; Sarah Geneser; Bowen Meng; Lei Xing
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

5.  Analysis of physical parameters and determination of inflection point for Flattening Filter Free beams in medical linear accelerator.

Authors:  A Pichandi; Kadirampatti Mani Ganesh; Amalraj Jerin; Karunakaran Balaji; Gurunath Kilara
Journal:  Rep Pract Oncol Radiother       Date:  2014-07-15

6.  Initial experience of hypofractionated radiation retreatment with true beam and flattening filter free beam in selected case reports of recurrent nasopharyngeal carcinoma.

Authors:  Filippo Alongi; Elena Clerici; Sara Pentimalli; Pietro Mancosu; Marta Scorsetti
Journal:  Rep Pract Oncol Radiother       Date:  2012-08-10

7.  Technical Report: Evaluation of peripheral dose for flattening filter free photon beams.

Authors:  E L Covington; T A Ritter; J M Moran; A M Owrangi; J I Prisciandaro
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

8.  A surface energy spectral study on the bone heterogeneity and beam obliquity using the flattened and unflattened photon beams.

Authors:  James C L Chow; Amir M Owrangi
Journal:  Rep Pract Oncol Radiother       Date:  2015-11-30

9.  Dosimetric comparison of intracranial metastasis treatment using two radiosurgery systems: TrueBeam STx with VMAT and Gamma Knife Model 4C.

Authors:  Vance Keeling; Ozer Algan; Salahuddin Ahmad; Sabbir Hossain
Journal:  J Radiosurg SBRT       Date:  2016

10.  Determination of an inflection point for a dosimetric analysis of unflattened beam using the first principle of derivatives by python code programming.

Authors:  Ravindra Shende; Gourav Gupta; Subash Macherla
Journal:  Rep Pract Oncol Radiother       Date:  2019-07-29
View more