Literature DB >> 25184057

Analysis of physical parameters and determination of inflection point for Flattening Filter Free beams in medical linear accelerator.

A Pichandi1, Kadirampatti Mani Ganesh2, Amalraj Jerin1, Karunakaran Balaji1, Gurunath Kilara1.   

Abstract

BACKGROUND: Medical Linear accelerators manufactured without flattening filters are increasing popular in recent days. The removal of flattening filter results in increased dose rate, reduced mean energy, reduction in head leakage and lateral scattering, which have shown advantageous when used for special treatment procedures. AIM: This study aims to analyze physical parameters of FFF beams and to determine the inflection point for standardizing the beam flatness and penumbra.
MATERIALS AND METHODS: The beam profiles and depth dose patterns were measured using Radiation Field Analyzer (RFA) with 0.13 cc cylindrical ion chamber. The beam energy characteristics, head scatter factor (Sc) were obtained for 6FFF and 10FFF beams and compared with 6 MV and 10 MV photons, respectively. The symmetry and stability of unflattened regions were also analyzed. In addition, the study proposes a simple physical concept for obtaining inflection point for FFF beams and results were compared using the Akima spline interpolation method. The inflection point was used to determine the field size and penumbra of FFF beams.
RESULTS: The Sc varied from 0.922 to 1.044 for 6FFF and from 0.913 to 1.044 for 10FFF with field sizes from 3 cm × 3 cm to 40 cm × 40 cm which is much less than FF beams. The obtained value of field size and penumbra for both simple physical concept and Akima spline interpolation methods is within the ±1.0 mm for the field size and ±2 mm penumbra. The results indicate that FFF beams reduce Sc compared with FF beams due to the absence of a flattening filter.
CONCLUSION: The proposed simple method to find field size and penumbra using inflection point can be accepted as it is closely approximated to mathematical results. Stability of these parameters was ascertained by repeated measurements and the study indicates good stability for FFF beam similar to that of FF beams.

Entities:  

Keywords:  Beam flatness; Flattening Filter Free photons (FFF); Inflection points

Year:  2014        PMID: 25184057      PMCID: PMC4150098          DOI: 10.1016/j.rpor.2014.01.004

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  6 in total

1.  Commissioning of photon beams of a flattening filter-free linear accelerator and the accuracy of beam modeling using an anisotropic analytical algorithm.

Authors:  Jan Hrbacek; Stephanie Lang; Stephan Klöck
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-12-02       Impact factor: 7.038

2.  Properties of unflattened photon beams shaped by a multileaf collimator.

Authors:  Falk Pönisch; Uwe Titt; Oleg N Vassiliev; Stephen F Kry; Radhe Mohan
Journal:  Med Phys       Date:  2006-06       Impact factor: 4.071

Review 3.  Current status and future perspective of flattening filter free photon beams.

Authors:  Dietmar Georg; Tommy Knöös; Brendan McClean
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

4.  Dosimetric characteristics of 6 and 10MV unflattened photon beams.

Authors:  Gabriele Kragl; Sacha af Wetterstedt; Barbara Knäusl; Mårten Lind; Patrick McCavana; Tommy Knöös; Brendan McClean; Dietmar Georg
Journal:  Radiother Oncol       Date:  2009-07-09       Impact factor: 6.280

5.  Initial experience of hypofractionated radiation retreatment with true beam and flattening filter free beam in selected case reports of recurrent nasopharyngeal carcinoma.

Authors:  Filippo Alongi; Elena Clerici; Sara Pentimalli; Pietro Mancosu; Marta Scorsetti
Journal:  Rep Pract Oncol Radiother       Date:  2012-08-10

6.  Unflattened photon beams from the standard flattening filter free accelerators for radiotherapy: Advantages, limitations and challenges.

Authors:  Sunil Dutt Sharma
Journal:  J Med Phys       Date:  2011-07
  6 in total
  4 in total

1.  A Monte Carlo Study of Photon Beam Characteristics on Various Linear Accelerator Filters.

Authors:  Pawiro S A; Azzi A; Soejoko D S
Journal:  J Biomed Phys Eng       Date:  2020-10-01

2.  Determination of inflection points of CyberKnife dose profiles within acceptability criteria of deviations in measurements.

Authors:  Neslihan Sarıgül; Fazlı Yağız Yedekçi; Mete Yeğiner; Fadıl Akyol; Haluk Utku
Journal:  Rep Pract Oncol Radiother       Date:  2019-11-12

3.  Monte-Carlo simulation of the Siemens Artiste linear accelerator flat 6 MV and flattening-filter-free 7 MV beam line.

Authors:  Alemeh Sadrollahi; Frank Nuesken; Norbert Licht; Christian Rübe; Yvonne Dzierma
Journal:  PLoS One       Date:  2019-01-08       Impact factor: 3.240

4.  Comparison of treatment plan quality of VMAT for esophageal carcinoma with: flattening filter beam versus flattening filter free beam.

Authors:  Wen-Zhao Sun; Li Chen; Xin Yang; Bin Wang; Xiao-Wu Deng; Xiao-Yan Huang
Journal:  J Cancer       Date:  2018-09-07       Impact factor: 4.207

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.