Literature DB >> 16848263

The effects of file size, sodium hypochlorite and blood on the accuracy of Root ZX apex locator in enlarged root canals: an in vitro study.

A K Ebrahim1, T Yoshioka, C Kobayashi, H Suda.   

Abstract

BACKGROUND: The initial electronic apex locator (EAL) length measurement is generally established with a small-sized file. It is not known whether file size would be interfering with the reading accuracy of the EAL. This study aimed to evaluate the effect of file size on the accuracy of Root ZX apex locator using an agar model when sodium hypochlorite solution or blood was present during electronic measurements in enlarged root canals.
METHODS: A total of 36 extracted lower premolars were used. In stage 1, the canals were instrumented using size 10-40 K-files with a size 40 K-file as the master apical file (MAF). The teeth were then divided randomly into two groups of 18 teeth each. In group A, the teeth were mounted in one per cent agar and irrigated with six per cent sodium hypochlorite solution (NaOCl), while in group B the teeth were mounted in agar and irrigated with human blood. In stage 2, the canals were enlarged using a size 60 K-file as the MAF. In stages 1 and 2, the apical portions of the canals were instrumented using the step-back sequence (up to a size 80 K-file). In stage 3, the canals were enlarged using a size 80 K-file as the MAF. In each stage, the length was measured with a Root ZX until the meter value reached 'APEX' using small and large size files.
RESULTS: Three-way ANOVA and Bonferroni test showed that file size, stage of preparation and type of irrigant all had a significant influence on the measurement error (P < 0.0001), with all the interactions between these three factors being significant (P < 0.0001).
CONCLUSIONS: As the diameter of the root canal increased, the measured length with the smaller size files became shorter. A file of a size close to the prepared canal diameter should be used for root length measurement in the presence of blood. In the presence of NaOCl, the Root ZX was highly accurate even when the file was much smaller than the diameter of the canal. The agar model was effective and suitable for testing EALs in vitro.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16848263     DOI: 10.1111/j.1834-7819.2006.tb00419.x

Source DB:  PubMed          Journal:  Aust Dent J        ISSN: 0045-0421            Impact factor:   2.291


  18 in total

1.  Clinical evaluation of Root ZX II electronic apex locator in primary teeth.

Authors:  S Saritha; K S Uloopi; C Vinay; R Chandra Sekhar; V V Rao
Journal:  Eur Arch Paediatr Dent       Date:  2012-02

2.  Effect of Sodium Hypochlorite Concentration on Electronic Apex Locator Reliability.

Authors:  Franck Diemer; Emma Plews; Marie Georgelin-Gurgel; Lora Mishra; Hyeon-Cheol Kim
Journal:  Materials (Basel)       Date:  2022-01-23       Impact factor: 3.623

3.  In vivo accuracy of conventional and digital radiographic methods in confirming root canal working length determination by Root ZX.

Authors:  Fernando Accorsi Orosco; Norberti Bernardineli; Roberto Brandão Garcia; Clovis Monteiro Bramante; Marco Antonio Húngaro Duarte; Ivaldo Gomes de Moraes
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

4.  Effect of pre-flaring and file size on the accuracy of two electronic apex locators.

Authors:  Manoel Brito-Júnior; Carla Cristina Camilo; Gil Moreira-Júnior; Jesus Djalma Pecora; Manoel Damião Sousa-Neto
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

5.  Comparative evaluation of root ZX Mini® apex locator and radiovisiography in determining the working length of primary molars: An In Vivo study.

Authors:  Rucha N Davalbhakta; Niraj S Gokhale; Shivayogi M Hugar; Chandrashekhar M Badakar; A Gowtham; Sanjana P Soneta
Journal:  J Oral Biol Craniofac Res       Date:  2021-02-17

6.  Comparative evaluation of accuracy of two electronic apex locators in the presence of various irrigants: An in vitro study.

Authors:  Saru Jain; Ravi Kapur
Journal:  Contemp Clin Dent       Date:  2012-09

7.  Accuracy of electronic apex locators to detect root canal perforations with inserted metallic posts: an ex vivo study.

Authors:  Benjamín Briseño Marroquín; Claudia Cortazar Fernández; Irene Schmidtmann; Brita Willershausen; Fernando Goldberg
Journal:  Head Face Med       Date:  2014-12-23       Impact factor: 2.151

8.  In vitro evaluation of Root ZX and Raypex 6 in teeth with different apical diameters.

Authors:  Ugur Aydin; Emrah Karataslioglu; Fatih Aksoy; Cihan Yildirim
Journal:  J Conserv Dent       Date:  2015 Jan-Feb

9.  The effect of file size on the accuracy of the raypex 5 apex locator: an in vitro study.

Authors:  Shiva Sadeghi; Masoomeh Abolghasemi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2008-05-15

10.  Effects of dissolving solutions on the accuracy of an electronic apex locator-integrated endodontic handpiece.

Authors:  Yakup Ustun; Ozgur Uzun; Ozgur Er; Murat Maden; Fatma Yalpı; Burhan Can Canakci
Journal:  ScientificWorldJournal       Date:  2013-11-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.