Literature DB >> 12519736

Simultaneous PET and NMR.

Paul K Marsden1, Daniel Strul, Stephen F Keevil, Steven C R Williams, Diana Cash.   

Abstract

There is currently great interest in combining data from different imaging modalities, either by image registration methods that are performed after the data has been acquired or using new devices that can acquire data from two modalities simultaneously, or near simultaneously. In this paper a small prototype NMR-compatible PET scanner capable of acquiring PET images simultaneously with either NMR images or NMR spectra is described. In an associated paper [1], Pamela Garlick describes some investigations of cardiac metabolism that have been made using this system. One of the main challenges in constructing an NMR-compatible PET scanner is that photomultiplier tubes, which are an essential element of nearly all current PET systems, will not function in a high magnetic field. In collaboration with Simon Cherry and the Crump Institute of Biomedical Imaging at UCLA Medical School, a small (5.4 cm diameter) NMR-compatible PET scanner that will operate within the bore of an NMR magnet has been developed. Long optical fibres are used to transport light from the scintillation crystals that form the detector head to photomultiplier tubes situated in a low magnetic field region several metres from the magnet. This system has been used to perform simultaneous PET and NMR spectroscopy measurements with a 9.4T spectroscopy system, and has also been used to obtain simultaneous PET and MR images in several MRI scanners including a 4.7T small bore animal imaging system. Current efforts in the development of this technology are directed at experimental studies on small animals, both because this is less demanding technically and because it is in this area that applications are likely to appear first. However, there is no reason in principle why human PET-MR would not be feasible. Below, work with the prototype system and the next stage in its development are described, and some of the future possibilities and challenges are discussed.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12519736     DOI: 10.1259/bjr.75.suppl_9.750053

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  17 in total

1.  Assessment of MR compatibility of a PET insert developed for simultaneous multiparametric PET/MR imaging on an animal system operating at 7 T.

Authors:  Hans F Wehrl; Martin S Judenhofer; Axel Thielscher; Petros Martirosian; Fritz Schick; Bernd J Pichler
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

2.  Time-of-flight PET and PET/MRI: recurrent dreams or actual realities?

Authors:  Giovanni Lucignani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-08       Impact factor: 9.236

3.  Simultaneous in vivo magnetic resonance imaging and radioactive measurements with the beta-MicroProbe.

Authors:  A Desbrée; L Rbah; J-B Langlois; D Grenier; R Mastrippolito; F Pain; L Pinot; P Lanièce; L Zimmer; H Gurden
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-06-27       Impact factor: 9.236

Review 4.  PET/MRI hybrid imaging: devices and initial results.

Authors:  Bernd J Pichler; Martin S Judenhofer; Hans F Wehrl
Journal:  Eur Radiol       Date:  2008-03-21       Impact factor: 5.315

Review 5.  PET/MRI system design.

Authors:  Gaspar Delso; Sibylle Ziegler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

Review 6.  Pre-clinical PET/MR: technological advances and new perspectives in biomedical research.

Authors:  Hans F Wehrl; Martin S Judenhofer; Stefan Wiehr; Bernd J Pichler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

Review 7.  Positron emission tomography/magnetic resonance imaging: the next generation of multimodality imaging?

Authors:  Bernd J Pichler; Hans F Wehrl; Armin Kolb; Martin S Judenhofer
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

8.  PET-MRI: Challenges and new directions.

Authors:  Aditya Daftary
Journal:  Indian J Nucl Med       Date:  2010-01

9.  PET/MRI: a different spin from under the rim.

Authors:  Rodney J Hicks; Eddie W F Lau
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

10.  Advances in multimodality molecular imaging.

Authors:  Habib Zaidi; Rameshwar Prasad
Journal:  J Med Phys       Date:  2009-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.