Literature DB >> 7725597

Lung lesions induced by continuous- and pulsed-wave (diagnostic) ultrasound in mice, rabbits, and pigs.

J F Zachary1, W D O'Brien.   

Abstract

These studies documented the presence or absence of macroscopic and microscopic intraparenchymal hemorrhage in individual lung lobes of mice, rabbits, and pigs exposed to continuous- and pulsed-wave (diagnostic) ultrasound; we described the character of and lesions associated with the hemorrhage and compared differences in the lesions among species and exposure conditions to investigate the pathogenic mechanisms and species differences associated with ultrasound-induced lung hemorrhage. In a series of three sequential interdependent studies, 312 mice, 91 rabbits, and 74 pigs were divided at random into experimental groups and exposed to continuous-wave ultrasound (3 kHz modulated at 120 Hz) of acoustic pressure levels ranging from 0 to 490 kPa for 5, 10, or 20 minutes. In a fourth study, three mice, 43 rabbits, and six pigs were divided at random into experimental groups and exposed to pulsed-wave ultrasound (3- and 6-MHz center frequency) of peak rarefactional acoustic pressure levels ranging from 0 to 5.6 MPa for 5 minutes. Macroscopic lesions induced by continuous- and pulsed-wave ultrasound consisted of dark red to black areas of hemorrhage that extended from visceral pleural surfaces into lung parenchyma. Hemorrhage appeared spatially related to the edges of lung lobes where pleura of dorsal and ventral surfaces met, occurred in specific lung lobes in all three species, and appeared anatomically related to lung that was closest to and in contiguous alignment with the ultrasound transducer and thus the path of the sound beam. Macroscopic lesions were similar in all species under all exposure conditions for both continuous- and pulsed-wave ultrasound; however, hemorrhage was not induced in pig lung exposed to pulsed-wave ultrasound at any peak rarefactional acoustic pressure level. Eighteen mice (145 kPa exposure pressure), 60 rabbits (145-460 kPa exposure pressure), and 58 pigs (145-490 kPa exposure pressure) from study 3 were used for microscopic evaluation of lung exposed to continuous-wave ultrasound; three mice (6 MHz; 2.9 and 5.4 MPa), 39 rabbits (3 and 6 MHz; 2.3-5.4 MPa), and six pigs (3 and 6 MHz; 3.3, 5.4, and 5.6 MPa) from study 4 were used for microscopic evaluation of lung exposed to pulsed-wave ultrasound. Microscopic lesions and the character of hemorrhage induced by continuous-wave ultrasound were different from those induced by pulsed-wave ultrasound. Lesions induced by continuous-wave ultrasound under all exposure conditions were similar in all three species. Lesions induced by pulsed-wave ultrasound under all exposure conditions were similar in all three species.(ABSTRACT TRUNCATED AT 400 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7725597     DOI: 10.1177/030098589503200106

Source DB:  PubMed          Journal:  Vet Pathol        ISSN: 0300-9858            Impact factor:   2.221


  14 in total

Review 1.  Section 8--clinical relevance. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 2.  Section 6--mechanical bioeffects in the presence of gas-carrier ultrasound contrast agents. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 3.  Section 7--discussion of the mechanical index and other exposure parameters. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 4.  Section 4--bioeffects in tissues with gas bodies. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

5.  Threshold estimation of ultrasound-induced lung hemorrhage in adult rabbits and comparison of thresholds in mice, rats, rabbits and pigs.

Authors:  William D O'Brien; Yan Yang; Douglas G Simpson; Leon A Frizzell; Rita J Miller; James P Blue; James F Zachary
Journal:  Ultrasound Med Biol       Date:  2006-11       Impact factor: 2.998

6.  Evaluation of the threshold for lung hemorrhage by diagnostic ultrasound and a proposed new safety index.

Authors:  Charles C Church; William D O'Brien
Journal:  Ultrasound Med Biol       Date:  2007-03-26       Impact factor: 2.998

7.  Contrast ultrasound imaging of the aorta alters vascular morphology and circulating von Willebrand factor in hypercholesterolemic rabbits.

Authors:  Brendon W Smith; Douglas G Simpson; Sandhya Sarwate; Rita J Miller; James P Blue; Alexander Haak; William D O'Brien; John W Erdman
Journal:  J Ultrasound Med       Date:  2012-05       Impact factor: 2.153

8.  Superthreshold behavior of ultrasound-induced lung hemorrhage in adult rats: role of pulse repetition frequency and pulse duration.

Authors:  William D O'Brien; Douglas G Simpson; Leon A Frizzell; James F Zachary
Journal:  J Ultrasound Med       Date:  2006-07       Impact factor: 2.153

9.  Acoustic Fountains and Atomization at Liquid Surfaces Excited by Diagnostic Ultrasound.

Authors:  Brandon Patterson; Douglas L Miller
Journal:  Ultrasound Med Biol       Date:  2019-05-14       Impact factor: 2.998

10.  Safety and bio-effects of ultrasound contrast agents.

Authors:  Gail ter Haar
Journal:  Med Biol Eng Comput       Date:  2009-07-14       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.