Literature DB >> 16781408

The value of patient activity level in the outcome of total hip arthroplasty.

Paul E Beaulé1, Frederic J Dorey, Ryan Hoke, Michel Le Duff, Harlan C Amstutz.   

Abstract

Commonly used total hip arthroplasty scores take into account pain, function, walking, and range of motion. The purpose of this study was to evaluate the value of patient activity level as part of the outcome of total hip arthroplasty. Using linear regression analysis, the relationship between patient activity level (University of California Los Angeles activity score), the Harris Hip Score, and the Short Form-12 health survey was evaluated in 152 patients (mean age, 58.7 years) with a mean follow-up 5.2 years (range, 2-21 years). The University of California Los Angeles activity scale had an R(2) value of 0.39 and 0.19 to the Short Form-12 physical and mental components, respectively, and 0.32 to the Harris Hip Score. By evaluating patient activity level, one obtains important qualitative information in assessing the clinical outcome after total hip arthroplasty.

Entities:  

Mesh:

Year:  2006        PMID: 16781408     DOI: 10.1016/j.arth.2005.09.004

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  23 in total

1.  The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene.

Authors:  Nathan A Mall; Ryan M Nunley; Jin Jun Zhu; William J Maloney; Robert L Barrack; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

2.  The fate of grafting acetabular defects during revision total hip arthroplasty.

Authors:  Nathan A Mall; Ryan M Nunley; Kirk E Smith; William J Maloney; John C Clohisy; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

3.  Periprosthetic femoral fracture as cause of early revision after short stem hip arthroplasty-a multicentric analysis.

Authors:  Sang-Min Kim; Seung-Beom Han; Kee Hyung Rhyu; Jeong Joon Yoo; Kwang-Jun Oh; Je Hyun Yoo; Kyung-Jae Lee; Seung-Jae Lim
Journal:  Int Orthop       Date:  2018-04-12       Impact factor: 3.075

4.  Physical activity level, leisure activities and related quality of life 1 year after lumbar decompression or total hip arthroplasty.

Authors:  Nanna Rolving; Kirstine H Obling; Finn B Christensen; Kirsten Fonager
Journal:  Eur Spine J       Date:  2012-10-18       Impact factor: 3.134

5.  Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws.

Authors:  Guido Garavaglia; Anne Lübbeke; Christophe Barea; Constantinos Roussos; Robin Peter; Pierre Hoffmeyer
Journal:  Int Orthop       Date:  2010-06-04       Impact factor: 3.075

6.  Downhill walking gait pattern discriminates between types of knee arthroplasty: improved physiological knee functionality in UKA versus TKA.

Authors:  Anatole V Wiik; Adeel Aqil; Sara Tankard; Andrew A Amis; Justin P Cobb
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-08-27       Impact factor: 4.342

7.  No differences in outcomes between cemented and uncemented acetabular components after 12-14 years: results from a randomized controlled trial comparing Duraloc with Charnley cups.

Authors:  Kristian Bjørgul; Wendy M Novicoff; S T Andersen; K Brevig; F Thu; M Wiig; O Ahlund
Journal:  J Orthop Traumatol       Date:  2010-03-03

8.  Cemented polyethylene cups in patients younger than 40 years.

Authors:  Daniël C J de Kam; Jean W M Gardeniers; Jan C M Hendriks; René P H Veth; B Willem Schreurs
Journal:  Clin Orthop Relat Res       Date:  2009-04-16       Impact factor: 4.176

9.  Which is the best activity rating scale for patients undergoing total joint arthroplasty?

Authors:  Florian D Naal; Franco M Impellizzeri; Michael Leunig
Journal:  Clin Orthop Relat Res       Date:  2008-06-28       Impact factor: 4.176

10.  Custom cementless stem improves hip function in young patients at 15-year followup.

Authors:  Xavier Flecher; Oliver Pearce; Sebastien Parratte; Jean-Manuel Aubaniac; Jean-Noel Argenson
Journal:  Clin Orthop Relat Res       Date:  2009-08-19       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.