[Pulmonary artery catheter in anaesthesiology and intensive care medicine].

E E C de Waal1, L de Rossi, W Buhre.   

Abstract

The indication for the use of the pulmonary artery catheter (PAC) in high-risk patients is still a matter of discussion. Observational studies suggested that the use of the PAC did not result in decreased mortality but may even lead to increased mortality and morbidity. Therefore, a number of randomized controlled trials have been performed throughout recent years in patients suffering from sepsis/ARDS, congestive heart failure, multi-organ failure and those undergoing high-risk non-cardiac surgery. The majority of recent randomized studies failed to demonstrate any benefit of the PAC with respect to mortality and morbidity. However, the use of the PAC was also regularly not associated with an increase in morbidity and/or mortality. This review gives an overview of measurement parameters obtained by the current generation of PACs, alternatives to the PAC and recent studies on the use of the PAC in clinical practice.

Entities:  

Mesh:

Year:  2006        PMID: 16775733     DOI: 10.1007/s00101-006-1037-0

Source DB:  PubMed          Journal:  Anaesthesist        ISSN: 0003-2417            Impact factor:   1.041


  49 in total

1.  A comparison of transoesophageal echocardiographic Doppler across the aortic valve and the thermodilution technique for estimating cardiac output.

Authors:  J Poelaert; C Schmidt; H Van Aken; F Hinder; T Mollhoff; H M Loick
Journal:  Anaesthesia       Date:  1999-02       Impact factor: 6.955

2.  A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients.

Authors:  James Dean Sandham; Russell Douglas Hull; Rollin Frederick Brant; Linda Knox; Graham Frederick Pineo; Christopher J Doig; Denny P Laporta; Sidney Viner; Louise Passerini; Hugh Devitt; Ann Kirby; Michael Jacka
Journal:  N Engl J Med       Date:  2003-01-02       Impact factor: 91.245

Review 3.  Practice guidelines for pulmonary artery catheterization: an updated report by the American Society of Anesthesiologists Task Force on Pulmonary Artery Catheterization.

Authors: 
Journal:  Anesthesiology       Date:  2003-10       Impact factor: 7.892

Review 4.  [Measurement of cardiac output].

Authors:  D A Reuter; A E Goetz
Journal:  Anaesthesist       Date:  2005-11       Impact factor: 1.041

5.  Intraoperative assessment of right ventricular volume and function.

Authors:  Raffaele De Simone; Ivo Wolf; Sibylle Mottl-Link; Bernd W Böttiger; Helmuth Rauch; Hans-Peter Meinzer; Siegfried Hagl
Journal:  Eur J Cardiothorac Surg       Date:  2005-06       Impact factor: 4.191

6.  Assessment of cardiac preload by indicator dilution and transoesophageal echocardiography.

Authors:  W Buhre; K Buhre; S Kazmaier; H Sonntag; A Weyland
Journal:  Eur J Anaesthesiol       Date:  2001-10       Impact factor: 4.330

7.  A prospective, randomized study of goal-oriented hemodynamic therapy in cardiac surgical patients.

Authors:  P Pölönen; E Ruokonen; M Hippeläinen; M Pöyhönen; J Takala
Journal:  Anesth Analg       Date:  2000-05       Impact factor: 5.108

8.  Use of the pulmonary artery catheter is not associated with worse outcome in the ICU.

Authors:  Yasser Sakr; Jean-Louis Vincent; Konrad Reinhart; Didier Payen; Christian J Wiedermann; Durk F Zandstra; Charles L Sprung
Journal:  Chest       Date:  2005-10       Impact factor: 9.410

9.  Comparison of esophageal Doppler, pulse contour analysis, and real-time pulmonary artery thermodilution for the continuous measurement of cardiac output.

Authors:  Berthold Bein; Frank Worthmann; Peter H Tonner; Andrea Paris; Markus Steinfath; Jürgen Hedderich; Jens Scholz
Journal:  J Cardiothorac Vasc Anesth       Date:  2004-04       Impact factor: 2.628

10.  Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery.

Authors:  Tong J Gan; Andrew Soppitt; Mohamed Maroof; Habib el-Moalem; Kerri M Robertson; Eugene Moretti; Peter Dwane; Peter S A Glass
Journal:  Anesthesiology       Date:  2002-10       Impact factor: 7.892

View more
  4 in total

Review 1.  [Echocardiography during acute hemodynamic instability].

Authors:  C Hainer; M Bernhard; K Scheuren; H Rauch; M A Weigand
Journal:  Anaesthesist       Date:  2006-10       Impact factor: 1.041

2.  Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output.

Authors:  Sumit Vasdev; Sandeep Chauhan; Minati Choudhury; Millind P Hote; Madhur Malik; Usha Kiran
Journal:  J Clin Monit Comput       Date:  2012-02-17       Impact factor: 2.502

Review 3.  The Use of Pulmonary Artery Catheter in Sepsis Patients: A Literature Review.

Authors:  Dimitrios Velissaris; Vasilios Karamouzos; Ioanna Kotroni; Charalampos Pierrakos; Menelaos Karanikolas
Journal:  J Clin Med Res       Date:  2016-09-29

4.  Influence of early goal-directed therapy using arterial waveform analysis on major complications after high-risk abdominal surgery: study protocol for a multicenter randomized controlled superiority trial.

Authors:  Leonard Montenij; Eric de Waal; Michael Frank; Paul van Beest; Ardine de Wit; Cas Kruitwagen; Wolfgang Buhre; Thomas Scheeren
Journal:  Trials       Date:  2014-09-16       Impact factor: 2.279

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.