Literature DB >> 10215707

A comparison of transoesophageal echocardiographic Doppler across the aortic valve and the thermodilution technique for estimating cardiac output.

J Poelaert1, C Schmidt, H Van Aken, F Hinder, T Mollhoff, H M Loick.   

Abstract

This study was undertaken in order to elucidate the differences between various planes of measurement and Doppler techniques (pulsed- vs. continuous-wave Doppler) across the aortic valve to estimate cardiac output. In 45 coronary artery bypass patients, cardiac output was measured each time using four different Doppler techniques (transverse and longitudinal plane, pulsed- and continuous-wave Doppler) and compared with the thermodilution technique. Measurements were performed after induction of anaesthesia and shortly after arrival in the intensive care unit. Optimal imaging was obtained in 91% of the patients, in whom a total of 82 measurements of cardiac output were performed. The respective mean (SD) areas of the aortic valve were 3.77 (0.71) cm2 in the transverse plane and 3.86 (0.89) cm2 in the longitudinal plane. A correlation of 0.87 was found between pulsed-wave Doppler cardiac output and the thermodilution technique in either transverse or longitudinal plane. Correlation coefficients of 0.82 and 0.84 were found between thermodilution cardiac output and transverse and longitudinal continuous-wave Doppler cardiac output, respectively. Although thermodilution cardiac output is a widely accepted clinical standard, transoesophageal Doppler echocardiography across the aortic valve offers adequate estimations of cardiac output. In particular, pulsed-wave Doppler cardiac output in both the transverse and longitudinal plane provides useful data.

Entities:  

Mesh:

Year:  1999        PMID: 10215707     DOI: 10.1046/j.1365-2044.1999.00666.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  10 in total

Review 1.  Recent advances: recent advances in intensive care.

Authors:  S Stott
Journal:  BMJ       Date:  2000-02-05

2.  Can a NICO monitor substitute for thermodilution to measure cardiac output in patients with coexisting tricuspid regurgitation?

Authors:  Naka Imakiire; Takeshi Omae; Akira Matsunaga; Ryuzo Sakata; Yuichi Kanmura
Journal:  J Anesth       Date:  2010-05-19       Impact factor: 2.078

Review 3.  [Pulmonary artery catheter in anaesthesiology and intensive care medicine].

Authors:  E E C de Waal; L de Rossi; W Buhre
Journal:  Anaesthesist       Date:  2006-06       Impact factor: 1.041

Review 4.  Newer methods of cardiac output monitoring.

Authors:  Yatin Mehta; Dheeraj Arora
Journal:  World J Cardiol       Date:  2014-09-26

Review 5.  Systematic review of cardiac output measurements by echocardiography vs. thermodilution: the techniques are not interchangeable.

Authors:  Mik Wetterslev; Hasse Møller-Sørensen; Rasmus Rothmann Johansen; Anders Perner
Journal:  Intensive Care Med       Date:  2016-03-01       Impact factor: 17.440

Review 6.  Point of care cardiac ultrasound applications in the emergency department and intensive care unit--a review.

Authors:  Robert T Arntfield; Scott J Millington
Journal:  Curr Cardiol Rev       Date:  2012-05

7.  Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient.

Authors:  Pablo Mercado; Julien Maizel; Christophe Beyls; Dimitri Titeca-Beauport; Magalie Joris; Loay Kontar; Antoine Riviere; Olivier Bonef; Thierry Soupison; Christophe Tribouilloy; Bertrand de Cagny; Michel Slama
Journal:  Crit Care       Date:  2017-06-09       Impact factor: 9.097

8.  Minimally invasive beat-by-beat monitoring of cardiac power in normal hearts and during acute ventricular dysfunction.

Authors:  Audun E Rimehaug; Eirik Skogvoll; Petter Aadahl; Oddveig Lyng; Dag O Nordhaug; Lasse Løvstakken; Idar Kirkeby-Garstad
Journal:  Physiol Rep       Date:  2016-10

Review 9.  Hemodynamic monitoring using trans esophageal echocardiography in patients with shock.

Authors:  Florence Boissier; François Bagate; Armand Mekontso Dessap
Journal:  Ann Transl Med       Date:  2020-06

10.  Cardiac output measurements via echocardiography versus thermodilution: A systematic review and meta-analysis.

Authors:  Yun Zhang; Yan Wang; Jing Shi; Zhiqiang Hua; Jinyu Xu
Journal:  PLoS One       Date:  2019-10-03       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.