[VIBE with parallel acquisition technique - a novel approach to dynamic contrast-enhanced MR imaging of the liver].

M Dobritz1, T Radkow, M Nittka, W Bautz, F A Fellner.   

Abstract

PURPOSE: The VIBE (volume interpolated breath-hold examination) sequence in combination with parallel acquisition technique (iPAT: integrated parallel acquisition technique) allows dynamic contrast-enhanced MRI of the liver with high temporal and spatial resolution. The aim of this study was to obtain first clinical experience with this technique for the detection and characterization of focal liver lesions.
MATERIALS AND METHODS: We examined 10 consecutive patients using a 1.5 T MR system (gradient field strength 30 mT/m) with a phased-array coil combination. Following sequences were acquired: T 2 -w TSE and T 1 -w FLASH, after administration of gadolinium, 6 VIBE sequences with iPAT (TR/TE/matrix/partition thickness/time of acquisition: 6.2 ms/ 3.2 ms/256 x 192/4 mm/13 s), as well as T 1 -weighted FLASH with fat saturation. Two observers evaluated the different sequences concerning the number of lesions and their dignity. Following lesions were found: hepatocellular carcinoma (5 patients), hemangioma (2), metastasis (1), cyst (1), adenoma (1).
RESULTS: The VIBE sequences were superior for the detection of lesions with arterial hyperperfusion with a total of 33 focal lesions. 21 lesions were found with T 2 -w TSE and 20 with plain T 1 -weighted FLASH. Diagnostic accuracy increased with the VIBE sequence in comparison to the other sequences.
CONCLUSION: VIBE with iPAT allows MR imaging of the liver with high spatial and temporal resolution providing dynamic contrast-enhanced information about the whole liver. This may lead to improved detection of liver lesions, especially hepatocellular carcinoma.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12063604     DOI: 10.1055/s-2002-32223

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  5 in total

1.  Combination of low and high resolution sequences in two orientations for dynamic contrast-enhanced MRI of the breast: more than a compromise.

Authors:  Toni W Vomweg; Andrea Teifke; R Peter Kunz; Christian Hintze; Alexander Hlawatsch; Annett Kern; Karl F Kreitner; Manfred Thelen
Journal:  Eur Radiol       Date:  2004-07-29       Impact factor: 5.315

Review 2.  [Modern visualization of the liver with MRT. Current trends and future perspectives].

Authors:  C J Zech; S O Schoenberg; K A Herrmann; O Dietrich; M I Menzel; T Lanz; A Wallnöfer; T Helmberger; M F Reiser
Journal:  Radiologe       Date:  2004-12       Impact factor: 0.635

3.  Fast magnetic resonance imaging of the knee using a parallel acquisition technique (mSENSE): a prospective performance evaluation.

Authors:  Karl-Friedrich Kreitner; Bernd Romaneehsen; Frank Krummenauer; Katja Oberholzer; Lars Peter Müller; Christoph Düber
Journal:  Eur Radiol       Date:  2006-05-30       Impact factor: 5.315

Review 4.  MRA of abdominal vessels: technical advances.

Authors:  Henrik J Michaely; Olaf Dietrich; Kambiz Nael; Sabine Weckbach; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2006-05-24       Impact factor: 5.315

5.  Whole-body MRI at 1.5 T and 3 T compared with FDG-PET-CT for the detection of tumour recurrence in patients with colorectal cancer.

Authors:  G P Schmidt; A Baur-Melnyk; A Haug; S Utzschneider; C R Becker; R Tiling; M F Reiser; K A Hermann
Journal:  Eur Radiol       Date:  2009-02-04       Impact factor: 5.315