Conversion factor for CT dosimetry to assess patient dose using a 256-slice CT scanner.

S Mori1, K Nishizawa, M Ohno, M Endo.   

Abstract

Recent rapid progress in CT technology has yielded equipment with large numbers of detector rows and standard computed tomography dose index (CTDI) is therefore no longer an adequate integration range. An integration range of 300 mm is necessary to accurately measure dose under a nominal beam width of 128 mm due to scattered radiation. However, such a long phantom is inconvenient to use routinely in cone-beam CT patient dose checking. To assess patient dose accurately with standard dosimetry methods, we determined a conversion factor (CF) which was calculated from the weighted dose profile integral (DPI(w)) for the 300 mm integration range with a 300 mm long CTDI phantom using a 300 mm long ionization chamber divided by that for the 100 mm integration range with a standard CTDI phantom (140 mm long) with a 100 mm long chamber. CF values increase with increasing nominal beam width and effective energy in the range from 1.5 to 2.0. CF values can also be adapted for use with other CT systems as their dose profiles are thought to be analogous to those for the 300 mm phantom and are useful in any hospital situation to assess accurate patient doses using standard dosimetry methods.

Entities:  

Mesh:

Year:  2006        PMID: 16728413     DOI: 10.1259/bjr/66519303

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  11 in total

1.  Radiation dose from single-heartbeat coronary CT angiography performed with a 320-detector row volume scanner.

Authors:  Andrew J Einstein; Carl D Elliston; Andrew E Arai; Marcus Y Chen; Richard Mather; Gregory D N Pearson; Robert L Delapaz; Edward Nickoloff; Ajoy Dutta; David J Brenner
Journal:  Radiology       Date:  2010-03       Impact factor: 11.105

2.  Absorbed radiation dose in radiosensitive organs during coronary CT angiography using 320-MDCT: effect of maximum tube voltage and heart rate variations.

Authors:  Boris Nikolic; Faisal Khosa; Pei-Jan Paul Lin; Atif N Khan; Sheryar Sarwar; Chun-Shan Yam; Laurence E Court; Vassilios Raptopoulos; Melvin E Clouse
Journal:  AJR Am J Roentgenol       Date:  2010-12       Impact factor: 3.959

3.  A method to acquire CT organ dose map using OSL dosimeters and ATOM anthropomorphic phantoms.

Authors:  Da Zhang; Xinhua Li; Yiming Gao; X George Xu; Bob Liu
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

4.  Using 80 kVp on a 320-row scanner for hepatic multiphasic CT reduces the contrast dose by 50 % in patients at risk for contrast-induced nephropathy.

Authors:  Narumi Taguchi; Seitaro Oda; Daisuke Utsunomiya; Yoshinori Funama; Takeshi Nakaura; Masanori Imuta; Sadahiro Yamamura; Hideaki Yuki; Masafumi Kidoh; Kenichiro Hirata; Tomohiro Namimoto; Masahiro Hatemura; Noriyuki Kai; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2016-05-30       Impact factor: 5.315

5.  Dose exposure of patients undergoing comprehensive stroke imaging by multidetector-row CT: comparison of 320-detector row and 64-detector row CT scanners.

Authors:  S Diekmann; E Siebert; R Juran; M Roll; W Deeg; H-C Bauknecht; F Diekmann; R Klingebiel; G Bohner
Journal:  AJNR Am J Neuroradiol       Date:  2010-01-28       Impact factor: 3.825

6.  320-row CT coronary angiography: effect of 100-kV tube voltages on image quality, contrast volume, and radiation dose.

Authors:  Chuanchen Zhang; Zhaoqi Zhang; Zixu Yan; Lei Xu; Wei Yu; Rui Wang
Journal:  Int J Cardiovasc Imaging       Date:  2010-11-26       Impact factor: 2.357

7.  Submillisievert imaging protocol using full reconstruction and advanced patient motion correction in 320-row area detector coronary CT angiography.

Authors:  Yuko Kawaguchi; Shinichiro Fujimoto; Kazuhisa Takamura; Etsuro Kato; Shoko Suda; Rie Matsumori; Makoto Hiki; Kanako K Kumamaru; Hiroyuki Daida
Journal:  Int J Cardiovasc Imaging       Date:  2017-09-12       Impact factor: 2.357

8.  Initial evaluation of coronary images from 320-detector row computed tomography.

Authors:  Frank J Rybicki; Hansel J Otero; Michael L Steigner; Gabriel Vorobiof; Leelakrishna Nallamshetty; Dimitrios Mitsouras; Hale Ersoy; Richard T Mather; Philip F Judy; Tianxi Cai; Karl Coyner; Kurt Schultz; Amanda G Whitmore; Marcelo F Di Carli
Journal:  Int J Cardiovasc Imaging       Date:  2008-03-27       Impact factor: 2.357

9.  Measurements of the dose delivered during CT exams using AAPM Task Group Report No. 111.

Authors:  Caroline Descamps; Mercedes Gonzalez; Edgardo Garrigo; Alejandro Germanier; Daniel Venencia
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

10.  Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography.

Authors:  Chun-Chao Chuang; Jay Wu
Journal:  Sci Rep       Date:  2018-02-08       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.