Literature DB >> 16683114

Estimation of dose to the unborn child at diagnostic X-ray examinations based on data registered in RIS/PACS.

Ebba Helmrot1, Håkan Pettersson, Michael Sandborg, Jonas Nilsson Altén.   

Abstract

The aim of this work was to determine mean absorbed doses to the unborn child in common conventional X-ray and computed tomography (CT) examinations and to find an approach for estimating foetal dose based on data registered in the Radiological Information System/Picture Archive and Communication System (RIS/PACS). The kerma-area product (KAP) and CT dose index (CTDI(vol)) in common examinations were registered using a human-shaped female dosimetry phantom. Foetal doses, D(f), were measured using thermoluminescent dosimeters placed inside the phantom and compared with calculated values. Measured foetal doses were given in relation to the KAP and the CTDI(vol) values, respectively. Conversion factor D(f)/KAP varies between 0.01 and 3.8 mGy/Gycm(2), depending on primary beam position, foetus age and beam quality (tube voltage and filtration). Conversion factors D(f)/CTDI(vol) are in the range 0.02 - 1.2 mGy/mGy, in which the foetus is outside or within the primary beam. We conclude that dose conversion factors based on KAP or CTDI(vol) values automatically generated by the RIS/PACS system can be used for rapid estimations of foetal dose for common examination techniques.

Entities:  

Mesh:

Year:  2006        PMID: 16683114     DOI: 10.1007/s00330-006-0286-2

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  8 in total

1.  Normalized conceptus doses for abdominal radiographic examinations calculated using a Monte Carlo technique.

Authors:  John Damilakis; Antonis Tzedakis; Liana Sideri; Kostas Perisinakis; Ion E Stamatelatos; Nicholas Gourtsoyiannis
Journal:  Med Phys       Date:  2002-11       Impact factor: 4.071

2.  Estimation of fetal and effective dose for CT examinations.

Authors:  E J Adams; D S Brettle; A P Jones; A R Hounsell; D J Mott
Journal:  Br J Radiol       Date:  1997-03       Impact factor: 3.039

3.  Embryo depth during the first trimester. Data required for embryo dosimetry.

Authors:  K Perisinakis; J Damilakis; E Vagios; N Gourtsoyiannis
Journal:  Invest Radiol       Date:  1999-07       Impact factor: 6.016

4.  Determining and reporting fetal radiation exposure from diagnostic radiation.

Authors:  P A Karam
Journal:  Health Phys       Date:  2000-11       Impact factor: 1.316

5.  A PC program for estimating organ dose and effective dose values in computed tomography.

Authors:  W A Kalender; B Schmidt; M Zankl; M Schmidt
Journal:  Eur Radiol       Date:  1999       Impact factor: 5.315

6.  Estimation of fetal radiation dose from computed tomography scanning in late pregnancy: depth-dose data from routine examinations.

Authors:  J Damilakis; K Perisinakis; A Voloudaki; N Gourtsoyiannis
Journal:  Invest Radiol       Date:  2000-09       Impact factor: 6.016

7.  Conceptus radiation dose and risk from chest screen-film radiography.

Authors:  John Damilakis; Kostas Perisinakis; Panos Prassopoulos; Evangelia Dimovasili; Haralambos Varveris; Nicholas Gourtsoyiannis
Journal:  Eur Radiol       Date:  2002-04-30       Impact factor: 5.315

8.  Software for the estimation of foetal radiation dose to patients and staff in diagnostic radiology.

Authors:  E K Osei; J B Darko; K Faulkner; C J Kotre
Journal:  J Radiol Prot       Date:  2003-06       Impact factor: 1.394

  8 in total
  6 in total

Review 1.  Risks to the fetus from diagnostic imaging during pregnancy: review and proposal of a clinical protocol.

Authors:  Mafalda Gomes; Alexandra Matias; Filipe Macedo
Journal:  Pediatr Radiol       Date:  2015-08-14

2.  Estimation of the radiation dose in pregnancy: an automated patient-specific model using convolutional neural networks.

Authors:  Tianwu Xie; Habib Zaidi
Journal:  Eur Radiol       Date:  2019-06-21       Impact factor: 5.315

3.  18F-Fludeoxyglucose Absorbed Dose Estimation in Fetus during Early Pregnancy.

Authors:  Nemat Ahmadi; Alireza Karimian; Mehdi Nasri Nasrabadi
Journal:  J Med Signals Sens       Date:  2022-05-12

4.  Assessment of CT dose to the fetus and pregnant female patient using patient-specific computational models.

Authors:  Tianwu Xie; Pierre-Alexandre Poletti; Alexandra Platon; Christoph D Becker; Habib Zaidi
Journal:  Eur Radiol       Date:  2017-09-08       Impact factor: 5.315

5.  Estimation of effective imaging dose for kilovoltage intratreatment monitoring of the prostate position during cancer radiotherapy.

Authors:  J A Ng; J Booth; P Poulsen; Z Kuncic; P J Keall
Journal:  Phys Med Biol       Date:  2013-08-12       Impact factor: 3.609

6.  Fetal radiation doses and subsequent risks from X-ray examinations: Should we be concerned?

Authors:  Ali Chaparian; Mahdi Aghabagheri
Journal:  Iran J Reprod Med       Date:  2013-11
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.