Literature DB >> 12462731

Normalized conceptus doses for abdominal radiographic examinations calculated using a Monte Carlo technique.

John Damilakis1, Antonis Tzedakis, Liana Sideri, Kostas Perisinakis, Ion E Stamatelatos, Nicholas Gourtsoyiannis.   

Abstract

The aim of the present study was to develop a reliable method for estimating conceptus radiation doses resulting from abdominal radiographic examinations for all trimesters of pregnancy. The method is based on normalized conceptus doses estimated using Monte Carlo modeling. The Monte Carlo N-Particle (MCNP) radiation transport code was employed in the current study. The validity of the MCNP computational approach was verified by comparison with dose data obtained in anthropomorphic phantoms simulating pregnancy at the three trimesters of gestation using thermoluminescence dosimetry (TLD). The results consist of radiation doses normalized to air kerma so that conceptus dose from any technique and x-ray unit used for abdominal radiography can be easily calculated. Normalized conceptus doses are presented for the first, second, and third trimesters of gestation for various kVp and total beam filtration values. Data apply to radiographic systems equipped with high frequency or 3 phase 12 pulse generators. A very good agreement was observed between the normalized conceptus doses estimated by TLD measurements and the MCNP simulation for all periods of gestation (maximum difference 8.1%). The results of MCNP procedures were compared to published data obtained by TLD measurements. Normalized conceptus dose values agree well, with most differences being lower than 10%. The normalized doses obtained in the current study are dependent on field size. However, for small changes in the size of the x-ray field, the change in normalized doses is not considerable. Accurate estimation of conceptus doses due to abdominal conventional x-ray examinations can be made using the dose data provided in the current study.

Entities:  

Mesh:

Year:  2002        PMID: 12462731     DOI: 10.1118/1.1517292

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  2 in total

1.  Estimation of dose to the unborn child at diagnostic X-ray examinations based on data registered in RIS/PACS.

Authors:  Ebba Helmrot; Håkan Pettersson; Michael Sandborg; Jonas Nilsson Altén
Journal:  Eur Radiol       Date:  2006-05-09       Impact factor: 5.315

2.  Organ and effective dose conversion coefficients for radiographic examinations of the pediatric skull estimated by Monte Carlo methods.

Authors:  J Stratakis; J Damilakis; N Gourtsoyiannis
Journal:  Eur Radiol       Date:  2005-03-18       Impact factor: 5.315

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.