The hysteresis effect in carpal kinematics.

Sunjay Berdia1, Walter H Short, Frederick W Werner, Jason K Green, Manohar Panjabi.   

Abstract

PURPOSE: Carpal bones show hysteresis that is dependent on the direction of wrist motion during a continuous active loading protocol. We describe an accurate methodology for analyzing the hysteresis effect and we apply this model to analyze the effect of sequential ligament sectioning on scapholunate instability.
METHODS: In 8 fresh cadaver forearms scaphoid, lunate, and third metacarpal motions were recorded while each wrist was moved in continuous cycles of active motion in flexion-extension and radioulnar deviation. Motions were analyzed for the intact state and after sequential sectioning of the scapholunate interosseous, scaphotrapezium, and radioscaphocapitate ligaments. Carpal motion was curve-fitted with respect to the third metacarpal motion using optimization criteria. The area between the 2 curves that represents opposite directions of wrist motion was measured to give the total hysteresis area. Repeated-measures analysis of variance was used to determine significance.
RESULTS: In the flexion-extension trials the scaphoid and lunate total hysteresis area was significantly greater than the intact state only after all 3 ligaments were sectioned. In the radioulnar deviation trials the scaphoid total hysteresis area was significantly greater than the intact after just scapholunate interosseous ligament sectioning; however, the lunate total hysteresis area decreased with additional sequential sectionings in 4 of the 8 specimens as compared with the intact state. These 4 specimens started with a significantly greater intact total hysteresis area than the other 4 specimens.
CONCLUSIONS: The computation of the total hysteresis area from the hysteresis effect was found to be a sensitive technique to determine the subtle onset of abnormal carpal motion. By using this technique in a ligament sectioning study significant increases in the total hysteresis area were seen after just scapholunate interosseous ligament sectioning during wrist radioulnar deviation. This subtle change may signify the onset of dynamic scapholunate instability. The total hysteresis area of the lunate in a subset of lax specimens did not increase after ligament sectioning. This divergent behavior may explain why some patients with scapholunate instability do not develop dorsal intercalated segmental instability.

Entities:  

Mesh:

Year:  2006        PMID: 16632053      PMCID: PMC2041845          DOI: 10.1016/j.jhsa.2005.12.028

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  31 in total

Review 1.  The natural progression of scaphoid instability.

Authors:  H K Watson; J Weinzweig; J Zeppieri
Journal:  Hand Clin       Date:  1997-02       Impact factor: 1.907

2.  Stepwise regression is an alternative to splines for fitting noisy data.

Authors:  T J Burkholder; R L Lieber
Journal:  J Biomech       Date:  1996-02       Impact factor: 2.712

3.  Wrist joint motion simulator.

Authors:  F W Werner; A K Palmer; J H Somerset; J J Tong; D B Gillison; M D Fortino; W H Short
Journal:  J Orthop Res       Date:  1996-07       Impact factor: 3.494

4.  In vivo knee kinematics derived using an inverse perspective technique.

Authors:  D A Dennis; R D Komistek; W A Hoff; S M Gabriel
Journal:  Clin Orthop Relat Res       Date:  1996-10       Impact factor: 4.176

5.  Capsulodesis in reconstructive hand surgery. Dorsal capsulodesis for the unstable scaphoid and volar capsulodesis following excision of the distal ulna.

Authors:  G Blatt
Journal:  Hand Clin       Date:  1987-02       Impact factor: 1.907

6.  Influence of joint laxity on scaphoid kinematics.

Authors:  M Garcia-Elias; M Ribe; J Rodriguez; M Cots; J Casas
Journal:  J Hand Surg Br       Date:  1995-06

7.  Wrist kinematics. Row, column or both?

Authors:  M A Craigen; J K Stanley
Journal:  J Hand Surg Br       Date:  1995-04

8.  Experimental instability in the lumbar spine.

Authors:  A M Kaigle; S H Holm; T H Hansson
Journal:  Spine (Phila Pa 1976)       Date:  1995-02-15       Impact factor: 3.468

9.  Stability increase of the lumbar spine with different muscle groups. A biomechanical in vitro study.

Authors:  H J Wilke; S Wolf; L E Claes; M Arand; A Wiesend
Journal:  Spine (Phila Pa 1976)       Date:  1995-01-15       Impact factor: 3.468

10.  A dynamic biomechanical study of scapholunate ligament sectioning.

Authors:  W H Short; F W Werner; M D Fortino; A K Palmer; K A Mann
Journal:  J Hand Surg Am       Date:  1995-11       Impact factor: 2.230

View more
  7 in total

1.  Understanding the relationship between image quality and motion velocity in gated computed tomography: preliminary work for 4-dimensional musculoskeletal imaging.

Authors:  Shian Chao Tay; Andrew N Primak; Joel G Fletcher; Bernhard Schmidt; Kai-Nan An; Cynthia H McCollough
Journal:  J Comput Assist Tomogr       Date:  2008 Jul-Aug       Impact factor: 1.826

2.  Four-dimensional computed tomographic imaging in the wrist: proof of feasibility in a cadaveric model.

Authors:  Shian-Chao Tay; Andrew N Primak; Joel G Fletcher; Bernhard Schmidt; Kimberly K Amrami; Richard A Berger; Cynthia H McCollough
Journal:  Skeletal Radiol       Date:  2007-09-06       Impact factor: 2.199

3.  A technique for quantifying wrist motion using four-dimensional computed tomography: approach and validation.

Authors:  Kristin Zhao; Ryan Breighner; David Holmes; Shuai Leng; Cynthia McCollough; Kai-Nan An
Journal:  J Biomech Eng       Date:  2015-06-03       Impact factor: 2.097

4.  Dynamic tracking of scaphoid, lunate, and capitate carpal bones using four-dimensional MRI.

Authors:  Mohammad Zarenia; Volkan Emre Arpinar; Andrew S Nencka; L Tugan Muftuler; Kevin M Koch
Journal:  PLoS One       Date:  2022-06-02       Impact factor: 3.752

5.  In vitro kinematics of the proximal interphalangeal joint in the finger after progressive disruption of the main supporting structures.

Authors:  Paolo Caravaggi; Benhoor Shamian; Linda Uko; Linda Chen; Eitan Melamed; John T Capo
Journal:  Hand (N Y)       Date:  2015-09

6.  Impact of Simulated Knee Injuries on the Patellofemoral and Tibiofemoral Kinematics Investigated with an Electromagnetic Tracking Approach: A Cadaver Study.

Authors:  Björn Rath; Malte Asseln; Marcel Betsch; Andreas Prescher; Markus Tingart; Jörg Eschweiler
Journal:  Biomed Res Int       Date:  2018-04-23       Impact factor: 3.411

7.  Four-dimensional real-time cine images of wrist joint kinematics using dual source CT with minimal time increment scanning.

Authors:  Yoon Seong Choi; Young Han Lee; Sungjun Kim; Hee Woo Cho; Ho-Taek Song; Jin-Suck Suh
Journal:  Yonsei Med J       Date:  2013-07       Impact factor: 2.759

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.