OBJECTIVE: High-resolution real-time three-dimensional (3D) imaging of the moving wrist may provide novel insights into the pathophysiology of joint instability. The purpose of this work was to assess the feasibility of using retrospectively gated spiral computed tomography (CT) to perform four-dimensional (4D) imaging of the moving wrist joint. MATERIALS AND METHODS: A cadaver forearm from below the elbow was mounted on a motion simulator which performed radioulnar deviation of the wrist at 30 cycles per minute. An electronic trigger from the simulator provided the "electrocardiogram" (ECG) signal required for gated reconstructions. Four-dimensional and 3D images were compared by a blinded observer for image quality and presence of artifacts. RESULTS: Image quality of 4D images was found to be excellent at the extremes of radial and ulnar deviation (end-motion phases). Some artifacts were seen in mid-motion phases. CONCLUSION: 4D CT musculoskeletal imaging is feasible. Four-dimensional CT may allow clinicians to assess functional (dynamic) instabilities of the wrist joint.
OBJECTIVE: High-resolution real-time three-dimensional (3D) imaging of the moving wrist may provide novel insights into the pathophysiology of joint instability. The purpose of this work was to assess the feasibility of using retrospectively gated spiral computed tomography (CT) to perform four-dimensional (4D) imaging of the moving wrist joint. MATERIALS AND METHODS: A cadaver forearm from below the elbow was mounted on a motion simulator which performed radioulnar deviation of the wrist at 30 cycles per minute. An electronic trigger from the simulator provided the "electrocardiogram" (ECG) signal required for gated reconstructions. Four-dimensional and 3D images were compared by a blinded observer for image quality and presence of artifacts. RESULTS: Image quality of 4D images was found to be excellent at the extremes of radial and ulnar deviation (end-motion phases). Some artifacts were seen in mid-motion phases. CONCLUSION: 4D CT musculoskeletal imaging is feasible. Four-dimensional CT may allow clinicians to assess functional (dynamic) instabilities of the wrist joint.
Authors: P J Keall; G Starkschall; H Shukla; K M Forster; V Ortiz; C W Stevens; S S Vedam; R George; T Guerrero; R Mohan Journal: Phys Med Biol Date: 2004-05-21 Impact factor: 3.609
Authors: Stephan Achenbach; Dieter Ropers; Axel Kuettner; Thomas Flohr; Bernd Ohnesorge; Herbert Bruder; Heike Theessen; Meri Karakaya; Werner G Daniel; Werner Bautz; Willi A Kalender; Katharina Anders Journal: Eur J Radiol Date: 2006-01-19 Impact factor: 3.528
Authors: Shian Chao Tay; Andrew N Primak; Joel G Fletcher; Bernhard Schmidt; Kai-Nan An; Cynthia H McCollough Journal: J Comput Assist Tomogr Date: 2008 Jul-Aug Impact factor: 1.826
Authors: S A Nehmeh; Y E Erdi; T Pan; A Pevsner; K E Rosenzweig; E Yorke; G S Mageras; H Schoder; Phil Vernon; O Squire; H Mostafavi; S M Larson; J L Humm Journal: Med Phys Date: 2004-12 Impact factor: 4.071
Authors: Shian Chao Tay; Andrew N Primak; Joel G Fletcher; Bernhard Schmidt; Kai-Nan An; Cynthia H McCollough Journal: J Comput Assist Tomogr Date: 2008 Jul-Aug Impact factor: 1.826
Authors: Marieke G A de Roo; Marijn Muurling; Johannes G G Dobbe; Michelle E Brinkhorst; Geert J Streekstra; Simon D Strackee Journal: J Hand Surg Eur Vol Date: 2019-02-27
Authors: Luca Buzzatti; Benyameen Keelson; Jildert Apperloo; Thierry Scheerlinck; Jean-Pierre Baeyens; Gert Van Gompel; Jef Vandemeulebroucke; Michel de Maeseneer; Johan de Mey; Nico Buls; Erik Cattrysse Journal: Sci Rep Date: 2019-02-04 Impact factor: 4.379