Literature DB >> 17805530

Four-dimensional computed tomographic imaging in the wrist: proof of feasibility in a cadaveric model.

Shian-Chao Tay1, Andrew N Primak, Joel G Fletcher, Bernhard Schmidt, Kimberly K Amrami, Richard A Berger, Cynthia H McCollough.   

Abstract

OBJECTIVE: High-resolution real-time three-dimensional (3D) imaging of the moving wrist may provide novel insights into the pathophysiology of joint instability. The purpose of this work was to assess the feasibility of using retrospectively gated spiral computed tomography (CT) to perform four-dimensional (4D) imaging of the moving wrist joint.
MATERIALS AND METHODS: A cadaver forearm from below the elbow was mounted on a motion simulator which performed radioulnar deviation of the wrist at 30 cycles per minute. An electronic trigger from the simulator provided the "electrocardiogram" (ECG) signal required for gated reconstructions. Four-dimensional and 3D images were compared by a blinded observer for image quality and presence of artifacts.
RESULTS: Image quality of 4D images was found to be excellent at the extremes of radial and ulnar deviation (end-motion phases). Some artifacts were seen in mid-motion phases.
CONCLUSION: 4D CT musculoskeletal imaging is feasible. Four-dimensional CT may allow clinicians to assess functional (dynamic) instabilities of the wrist joint.

Mesh:

Year:  2007        PMID: 17805530     DOI: 10.1007/s00256-007-0374-7

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  39 in total

1.  Motion artifacts in subsecond conventional CT and electron-beam CT: pictorial demonstration of temporal resolution.

Authors:  C H McCollough; M R Bruesewitz; T R Daly; F E Zink
Journal:  Radiographics       Date:  2000 Nov-Dec       Impact factor: 5.333

2.  Acquiring 4D thoracic CT scans using a multislice helical method.

Authors:  P J Keall; G Starkschall; H Shukla; K M Forster; V Ortiz; C W Stevens; S S Vedam; R George; T Guerrero; R Mohan
Journal:  Phys Med Biol       Date:  2004-05-21       Impact factor: 3.609

3.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT.

Authors:  Tinsu Pan; Ting-Yim Lee; Eike Rietzel; George T Y Chen
Journal:  Med Phys       Date:  2004-02       Impact factor: 4.071

4.  Kinematics of the midcarpal and radiocarpal joints in radioulnar deviation: an in vitro study.

Authors:  Robert Kaufmann; Jamie Pfaeffle; Brad Blankenhorn; Kathryne Stabile; Doug Robertson; Robert Goitz
Journal:  J Hand Surg Am       Date:  2005-09       Impact factor: 2.230

5.  Contrast-enhanced coronary artery visualization by dual-source computed tomography--initial experience.

Authors:  Stephan Achenbach; Dieter Ropers; Axel Kuettner; Thomas Flohr; Bernd Ohnesorge; Herbert Bruder; Heike Theessen; Meri Karakaya; Werner G Daniel; Werner Bautz; Willi A Kalender; Katharina Anders
Journal:  Eur J Radiol       Date:  2006-01-19       Impact factor: 3.528

6.  Evaluation of a reduced dose protocol for respiratory gated lung computed tomography in an animal model.

Authors:  Thomas Elgeti; Hans Proquitté; Noga E Rogalla; Jürgen Mews; Bernd Hamm; Gerd Schmalisch; Patrik Rogalla
Journal:  Invest Radiol       Date:  2007-04       Impact factor: 6.016

7.  Understanding the relationship between image quality and motion velocity in gated computed tomography: preliminary work for 4-dimensional musculoskeletal imaging.

Authors:  Shian Chao Tay; Andrew N Primak; Joel G Fletcher; Bernhard Schmidt; Kai-Nan An; Cynthia H McCollough
Journal:  J Comput Assist Tomogr       Date:  2008 Jul-Aug       Impact factor: 1.826

8.  Multisegment and halfscan reconstruction of 16-slice computed tomography for assessment of regional and global left ventricular myocardial function.

Authors:  Marc Dewey; Mira Müller; Florian Teige; Dirk Schnapauff; Tania Schink; Bernd Hamm; Alexander Lembcke
Journal:  Invest Radiol       Date:  2006-04       Impact factor: 6.016

9.  [Cardiac multidetector-row CT: first clinical results of retrospectively ECG-gated spiral with optimized temporal and spatial resolution].

Authors:  A F Kopp; B Ohnesorge; T Flohr; C Georg; S Schröder; A Küttner; J Martensen; C D Claussen
Journal:  Rofo       Date:  2000-05

10.  Four-dimensional (4D) PET/CT imaging of the thorax.

Authors:  S A Nehmeh; Y E Erdi; T Pan; A Pevsner; K E Rosenzweig; E Yorke; G S Mageras; H Schoder; Phil Vernon; O Squire; H Mostafavi; S M Larson; J L Humm
Journal:  Med Phys       Date:  2004-12       Impact factor: 4.071

View more
  7 in total

1.  Dynamic CT technique for assessment of wrist joint instabilities.

Authors:  Shuai Leng; Kristin Zhao; Mingliang Qu; Kai-Nan An; Richard Berger; Cynthia H McCollough
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

2.  Experimental determination of the elbow's center of rotation using the VICON™ optoelectronic motion capture system.

Authors:  Elvire Guerre; Pascale Laronde; Jérôme Cussonneau; Christian Fontaine; Guillaume Wavreille
Journal:  Surg Radiol Anat       Date:  2015-11-20       Impact factor: 1.246

3.  Understanding the relationship between image quality and motion velocity in gated computed tomography: preliminary work for 4-dimensional musculoskeletal imaging.

Authors:  Shian Chao Tay; Andrew N Primak; Joel G Fletcher; Bernhard Schmidt; Kai-Nan An; Cynthia H McCollough
Journal:  J Comput Assist Tomogr       Date:  2008 Jul-Aug       Impact factor: 1.826

4.  Dynamic CT Scan of the Normal Scapholunate Joint in a Clenched Fist and Radial and Ulnar Deviation.

Authors:  Paul M Kelly; John G Hopkins; Andrew J Furey; Daniel S Squire
Journal:  Hand (N Y)       Date:  2017-08-29

5.  A four-dimensional-CT study of in vivo scapholunate rotation axes: possible implications for scapholunate ligament reconstruction.

Authors:  Marieke G A de Roo; Marijn Muurling; Johannes G G Dobbe; Michelle E Brinkhorst; Geert J Streekstra; Simon D Strackee
Journal:  J Hand Surg Eur Vol       Date:  2019-02-27

6.  Four-dimensional CT as a valid approach to detect and quantify kinematic changes after selective ankle ligament sectioning.

Authors:  Luca Buzzatti; Benyameen Keelson; Jildert Apperloo; Thierry Scheerlinck; Jean-Pierre Baeyens; Gert Van Gompel; Jef Vandemeulebroucke; Michel de Maeseneer; Johan de Mey; Nico Buls; Erik Cattrysse
Journal:  Sci Rep       Date:  2019-02-04       Impact factor: 4.379

7.  Four-dimensional real-time cine images of wrist joint kinematics using dual source CT with minimal time increment scanning.

Authors:  Yoon Seong Choi; Young Han Lee; Sungjun Kim; Hee Woo Cho; Ho-Taek Song; Jin-Suck Suh
Journal:  Yonsei Med J       Date:  2013-07       Impact factor: 2.759

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.