Literature DB >> 16607495

Automated vs. manual assessment of left ventricular function in cardiac multidetector row computed tomography: comparison with magnetic resonance imaging.

Andreas H Mahnken1, Georg Mühlenbruch, Ralf Koos, Sven Stanzel, Petra Simone Busch, Mathias Niethammer, Rolf W Günther, Joachim E Wildberger.   

Abstract

We compared semiautomatic contour detection and manual contour tracing in cardiac multidetector row computed tomography (MDCT) with magnetic resonance imaging (MRI) for calculation of left-ventricular (LV) volumes. The study included 30 patients who underwent contrast-enhanced cardiac MDCT and cardiac cine-MRI. Were calculated 8 mm short-axis slices from MDCT data using three-dimensional multiphase image reconstruction. LV volumes including peak ejection rate and peak filling rate were calculated from manually and semiautomatically determined contours. Results were compared to those from cine-MRI with manually drawn contours as the standard of reference. We found good agreement for the LV volumes, with an ejection fraction of 47.1+/-9.4% for manually drawn contours, 47.9+/-9.9% for semiautomatically detected contours on MDCT, and 48.0+/-10.2% for MRI. Except for peak-filling rate analysis of variance revealed no difference between any of these techniques. Bland-Altman plots and Lin's concordance correlation coefficient showed best agreement between MRI and manual contour tracing in MDCT. Calculation of LV volumes using either semiautomatic or manual contour tracing in cardiac MDCT is therefore feasible when compared to MRI. Automated contour detection needs to be improved to equal manual contour tracing.

Entities:  

Mesh:

Year:  2006        PMID: 16607495     DOI: 10.1007/s00330-006-0226-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  16 in total

1.  Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance; are they interchangeable?

Authors:  N G Bellenger; M I Burgess; S G Ray; A Lahiri; A J Coats; J G Cleland; D J Pennell
Journal:  Eur Heart J       Date:  2000-08       Impact factor: 29.983

2.  Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: initial experience.

Authors:  Kai Uwe Juergens; Matthias Grude; David Maintz; Eva Maria Fallenberg; Thomas Wichter; Walter Heindel; Roman Fischbach
Journal:  Radiology       Date:  2003-12-10       Impact factor: 11.105

3.  Acute myocardial infarction: assessment of left ventricular function with 16-detector row spiral CT versus MR imaging--study in pigs.

Authors:  Andreas H Mahnken; Marcus Katoh; Philipp Bruners; Elmar Spuentrup; Joachim E Wildberger; Rolf W Günther; Arno Buecker
Journal:  Radiology       Date:  2005-06-13       Impact factor: 11.105

4.  Assessment of left ventricular parameters using 16-MDCT and new software for endocardial and epicardial border delineation.

Authors:  Thomas Schlosser; Konstantin Pagonidis; Christoph U Herborn; Peter Hunold; Kai-Uwe Waltering; Thomas C Lauenstein; Jörg Barkhausen
Journal:  AJR Am J Roentgenol       Date:  2005-03       Impact factor: 3.959

5.  A concordance correlation coefficient to evaluate reproducibility.

Authors:  L I Lin
Journal:  Biometrics       Date:  1989-03       Impact factor: 2.571

6.  Sixteen-slice spiral CT versus MR imaging for the assessment of left ventricular function in acute myocardial infarction.

Authors:  Andreas H Mahnken; Ralf Koos; Marcus Katoh; Elmar Spuentrup; Petra Busch; Joachim E Wildberger; Harald P Kühl; Rolf W Günther
Journal:  Eur Radiol       Date:  2005-01-29       Impact factor: 5.315

7.  [Assessment of global and regional left ventricular function with a 16-slice spiral-CT using two different software tools for quantitative functional analysis and qualitative evaluation of wall motion changes in comparison with magnetic resonance imaging].

Authors:  K Koch; F Oellig; P Kunz; P Bender; K Oberholzer; P Mildenberger; U Hake; K-F Kreitner; M Thelen
Journal:  Rofo       Date:  2004-12

8.  Time-effectiveness, observer-dependence, and accuracy of measurements of left ventricular ejection fraction using 4-channel MDCT.

Authors:  T Boehm; H Alkadhi; M Roffi; J K Willmann; L M Desbiolles; B Marincek; S Wildermuth
Journal:  Rofo       Date:  2004-04

9.  Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction.

Authors:  H D White; R M Norris; M A Brown; P W Brandt; R M Whitlock; C J Wild
Journal:  Circulation       Date:  1987-07       Impact factor: 29.690

10.  Long-term survival of medically treated patients in the Coronary Artery Surgery Study (CASS) Registry.

Authors:  M Emond; M B Mock; K B Davis; L D Fisher; D R Holmes; B R Chaitman; G C Kaiser; E Alderman; T Killip
Journal:  Circulation       Date:  1994-12       Impact factor: 29.690

View more
  14 in total

1.  Left ventricular myocardium segmentation on delayed phase of multi-detector row computed tomography.

Authors:  I-Chen Tsai; Yu-Len Huang; Po-Ting Liu; Min-Chi Chen
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-04-19       Impact factor: 2.924

2.  Accuracy of automated attenuation-based 3-dimensional segmentation: in the analysis of left ventricular function compared with magnetic resonance imaging.

Authors:  Harald Brodoefel; Ilias Tsiflikas; Ulrich Kramer; Nina Lang; Anja Reimann; Christoph Burgstahler; Claus D Claussen; Martin Heuschmid
Journal:  Tex Heart Inst J       Date:  2012

3.  Absence of left ventricular concentric hypertrophy: a prerequisite for zero coronary calcium score.

Authors:  Shoichi Ehara; Nobuyuki Shirai; Takuhiro Okuyama; Kenji Matsumoto; Yoshiki Matsumura; Minoru Yoshiyama
Journal:  Heart Vessels       Date:  2010-12-23       Impact factor: 2.037

4.  Quantitative assessment of left ventricular function with dual-source CT in comparison to cardiac magnetic resonance imaging: initial findings.

Authors:  S Busch; T R C Johnson; B J Wintersperger; N Minaifar; A Bhargava; C Rist; M F Reiser; C Becker; K Nikolaou
Journal:  Eur Radiol       Date:  2007-10-02       Impact factor: 5.315

5.  Quantification of left ventricular function and mass in heart transplant recipients using dual-source CT and MRI: initial clinical experience.

Authors:  Gorka Bastarrika; Maria Arraiza; Carlo N De Cecco; Stefano Mastrobuoni; Matias Ubilla; Gregorio Rábago
Journal:  Eur Radiol       Date:  2008-05-20       Impact factor: 5.315

6.  Global left-ventricular function assessment using dual-source multidetector CT: effect of improved temporal resolution on ventricular volume measurement.

Authors:  Michael Puesken; Roman Fischbach; Mirja Wenker; Harald Seifarth; David Maintz; Walter Heindel; Kai Uwe Juergens
Journal:  Eur Radiol       Date:  2008-05-01       Impact factor: 5.315

7.  Simple area-based measurement for multidetector computed tomography to predict left ventricular size.

Authors:  Christopher L Schlett; Dylan C Kwait; Amir A Mahabadi; Fabian Bamberg; Christopher J O'Donnell; Caroline S Fox; Udo Hoffmann
Journal:  Eur Radiol       Date:  2010-03-04       Impact factor: 5.315

8.  Quantification of left ventricular function and mass in cardiac Dual-Source CT (DSCT) exams: comparison of manual and semiautomatic segmentation algorithms.

Authors:  Gorka Bastarrika; María Arraiza; Jesús C Pueyo; María J Herraiz; Beatriz Zudaire; Alberto Villanueva
Journal:  Eur Radiol       Date:  2008-02-22       Impact factor: 5.315

9.  Clinical feasibility of a myocardial signal intensity threshold-based semi-automated cardiac magnetic resonance segmentation method.

Authors:  Akos Varga-Szemes; Giuseppe Muscogiuri; U Joseph Schoepf; Julian L Wichmann; Pal Suranyi; Carlo N De Cecco; Paola M Cannaò; Matthias Renker; Stefanie Mangold; Mary A Fox; Balazs Ruzsics
Journal:  Eur Radiol       Date:  2015-08-13       Impact factor: 5.315

10.  The reliability of automatic measurement of left ventricular function with dual-source computed tomography datasets.

Authors:  G J de Jonge; P M A van Ooijen; P A van der Vleuten; D D Lubbers; J H Kasemier; G H de Bock; M Oudkerk
Journal:  Eur Radiol       Date:  2009-12       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.