Literature DB >> 16586136

Follow-up assessment of CPAP efficacy in patients with obstructive sleep apnea using an ambulatory device based on peripheral arterial tonometry.

Stephen D Pittman1, Giora Pillar, Richard B Berry, Atul Malhotra, Mary M MacDonald, David P White.   

Abstract

This study aimed to assess the accuracy of a wrist-worn device based on peripheral arterial tonometry (Watch_PAT 100) to detect residual episodes of respiratory disturbance during continuous positive airway pressure (CPAP) therapy. Concurrent polysomnography was used as the reference standard to identify sleep disordered breathing (SDB) events. The study was conducted in three sleep laboratories affiliated with tertiary care academic medical centers. Seventy patients using CPAP to treat obstructive sleep apnea for at least 3 months, following an in-laboratory titration to determine the optimal therapeutic positive airway pressure, participated in this study. Symptoms indicating suboptimal therapy were not required for participation, but self-reported adherence to CPAP therapy was necessary for inclusion. Interventions are not applicable in this study. The accuracy of the PAT-derived respiratory disturbance index (PAT RDI scored by automated algorithm) to detect residual SDB on CPAP was assessed against polysomnography (PSG) using Bland-Altman analysis, receiver-operator characteristic (ROC) curves, and likelihood ratios for increasing (LR+) and decreasing (LR-) the probability of moderate-severe SDB in the study population. Respiratory events on the PSG were quantified using standard criteria for research investigations ("Chicago criteria") to yield a PSG RDI.C. Based on the PSG results, 19% of the participants had moderate-severe SDB (PSG RDI.C>15 events per hour) on their prescribed pressure. For PAT RDI >15 events per hour, the area under the ROC curve was 0.95 (SE 0.03, p < 0.0001, 95% CI 0.89 to 1.00), the LR+ was 8.04 (95% CI 3.64-17.7), and the LR- was 0.17 (95% CI 0.05-0.62). The mean difference between the PAT RDI and PSG RDI.C was three (2SD 14.5) events per hour. Therefore, residual moderate-severe SDB on CPAP was not uncommon in a multicenter population self-reporting adherence to CPAP therapy to treat obstructive sleep apnea. The Watch_PAT device accurately identified participants with moderate-severe SDB while using CPAP in the attended setting of a sleep laboratory.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16586136     DOI: 10.1007/s11325-006-0058-x

Source DB:  PubMed          Journal:  Sleep Breath        ISSN: 1520-9512            Impact factor:   2.816


  27 in total

Review 1.  Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research. The Report of an American Academy of Sleep Medicine Task Force.

Authors: 
Journal:  Sleep       Date:  1999-08-01       Impact factor: 5.849

2.  Proposed supplements and amendments to 'A Manual of Standardized Terminology, Techniques and Scoring System for Sleep Stages of Human Subjects', the Rechtschaffen & Kales (1968) standard.

Authors:  T Hori; Y Sugita; E Koga; S Shirakawa; K Inoue; S Uchida; H Kuwahara; M Kousaka; T Kobayashi; Y Tsuji; M Terashima; K Fukuda; N Fukuda
Journal:  Psychiatry Clin Neurosci       Date:  2001-06       Impact factor: 5.188

3.  Modafinil as adjunct therapy for daytime sleepiness in obstructive sleep apnea.

Authors:  A I Pack; J E Black; J R Schwartz; J K Matheson
Journal:  Am J Respir Crit Care Med       Date:  2001-11-01       Impact factor: 21.405

4.  Evaluation of a portable device based on peripheral arterial tone for unattended home sleep studies.

Authors:  Amir Bar; Giora Pillar; Itsik Dvir; Jacob Sheffy; Robert P Schnall; Peretz Lavie
Journal:  Chest       Date:  2003-03       Impact factor: 9.410

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  A novel adaptive wrist actigraphy algorithm for sleep-wake assessment in sleep apnea patients.

Authors:  Jan Hedner; Giora Pillar; Stephen D Pittman; Ding Zou; Ludger Grote; David P White
Journal:  Sleep       Date:  2004-12-15       Impact factor: 5.849

7.  Periodic, profound peripheral vasoconstriction--a new marker of obstructive sleep apnea.

Authors:  R P Schnall; A Shlitner; J Sheffy; R Kedar; P Lavie
Journal:  Sleep       Date:  1999-11-01       Impact factor: 5.849

8.  Low-concentration carbon dioxide is an effective adjunct to positive airway pressure in the treatment of refractory mixed central and obstructive sleep-disordered breathing.

Authors:  Robert Joseph Thomas; Robert W Daly; J Woodrow Weiss
Journal:  Sleep       Date:  2005-01       Impact factor: 5.849

9.  Using a wrist-worn device based on peripheral arterial tonometry to diagnose obstructive sleep apnea: in-laboratory and ambulatory validation.

Authors:  Stephen D Pittman; Najib T Ayas; Mary M MacDonald; Atul Malhotra; Robert B Fogel; David P White
Journal:  Sleep       Date:  2004-08-01       Impact factor: 5.849

10.  A new method for measuring daytime sleepiness: the Epworth sleepiness scale.

Authors:  M W Johns
Journal:  Sleep       Date:  1991-12       Impact factor: 5.849

View more
  17 in total

Review 1.  Obstructive sleep apnea devices for out-of-center (OOC) testing: technology evaluation.

Authors:  Nancy A Collop; Sharon L Tracy; Vishesh Kapur; Reena Mehra; David Kuhlmann; Sam A Fleishman; Joseph M Ojile
Journal:  J Clin Sleep Med       Date:  2011-10-15       Impact factor: 4.062

2.  Monitoring peripheral arterial tone (PAT) to diagnose sleep apnea in the home.

Authors:  David P White
Journal:  J Clin Sleep Med       Date:  2008-02-15       Impact factor: 4.062

3.  Improved follow-up by peripheral arterial tonometry in CPAP-treated patients with obstructive sleep apnea and persistent excessive daytime sleepiness.

Authors:  C Schöbel; S Knorre; M Glos; C Garcia; I Fietze; T Penzel
Journal:  Sleep Breath       Date:  2018-06-29       Impact factor: 2.816

4.  Respiratory event detection by a positive airway pressure device.

Authors:  Richard B Berry; Clete A Kushida; Meir H Kryger; Haideliza Soto-Calderon; Bethany Staley; Samuel T Kuna
Journal:  Sleep       Date:  2012-03-01       Impact factor: 5.849

5.  Home-based diagnosis of obstructive sleep apnea in an urban population.

Authors:  Natasha Garg; Andrew J Rolle; Todd A Lee; Bharati Prasad
Journal:  J Clin Sleep Med       Date:  2014-08-15       Impact factor: 4.062

6.  Detection of upper airway status and respiratory events by a current generation positive airway pressure device.

Authors:  Qing Yun Li; Richard B Berry; Mark G Goetting; Bethany Staley; Haideliza Soto-Calderon; Sheila C Tsai; Jeffrey G Jasko; Allan I Pack; Samuel T Kuna
Journal:  Sleep       Date:  2015-04-01       Impact factor: 5.849

7.  Reliability of the Watch-PAT 200 in detecting sleep apnea in highway bus drivers.

Authors:  Melike Yuceege; Hikmet Firat; Ahmet Demir; Sadik Ardic
Journal:  J Clin Sleep Med       Date:  2013-04-15       Impact factor: 4.062

8.  Portable monitoring and autotitration versus polysomnography for the diagnosis and treatment of sleep apnea.

Authors:  Richard B Berry; Gilbert Hill; Linda Thompson; Valorea McLaurin
Journal:  Sleep       Date:  2008-10       Impact factor: 5.849

9.  Effective Apnea-Hypopnea Index ("Effective AHI"): A New Measure of Effectiveness for Positive Airway Pressure Therapy.

Authors:  Scott B Boyd; Raghu Upender; Arthur S Walters; R Lucas Goodpaster; Jeffrey J Stanley; Li Wang; Rameela Chandrasekhar
Journal:  Sleep       Date:  2016-11-01       Impact factor: 5.849

10.  Accuracy of autotitrating CPAP to estimate the residual Apnea-Hypopnea Index in patients with obstructive sleep apnea on treatment with autotitrating CPAP.

Authors:  Himanshu Desai; Anil Patel; Pinal Patel; Brydon J B Grant; M Jeffery Mador
Journal:  Sleep Breath       Date:  2009-05-01       Impact factor: 2.816

View more