Simultaneous B-M-mode scanning method for real-time full-range Fourier domain optical coherence tomography.

Yoshiaki Yasuno1, Shuichi Makita, Takashi Endo, Gouki Aoki, Masahide Itoh, Toyohiko Yatagai.   

Abstract

High-speed complex full-range Fourier domain optical coherence tomography (FD-OCT) is demonstrated. In this FD-OCT, the phase modulation of a reference beam (M scan) and transversal scanning (B scan) are simultaneously performed. The Fourier transform method is applied along the direction of the B scan to reconstruct complex spectra, and the complex spectra comprise a full-range OCT image. Because of this simultaneous B-M-mode scan, the FD-OCT requires only a single A scan for each single transversal position to obtain a full-range FD-OCT image. A simple but slow version of the FD-OCT visualizes the cross section of a plastic plate. A modified fast version of this FD-OCT investigates a sweat duct in a finger pad in vivo and visualizes it with an acquisition time of 27 ms.

Entities:  

Mesh:

Year:  2006        PMID: 16572705     DOI: 10.1364/ao.45.001861

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  21 in total

1.  Comparison of phase-shifting techniques for in vivo full-range, high-speed Fourier-domain optical coherence tomography.

Authors:  Dae Yu Kim; John S Werner; Robert J Zawadzki
Journal:  J Biomed Opt       Date:  2010 Sep-Oct       Impact factor: 3.170

2.  Sample motion-insensitive, full-range, complex, spectral-domain optical-coherence tomography.

Authors:  Stefan Zotter; Michael Pircher; Erich Götzinger; Teresa Torzicky; Marco Bonesi; Christoph K Hitzenberger
Journal:  Opt Lett       Date:  2010-12-01       Impact factor: 3.776

3.  Space-division multiplexing optical coherence tomography.

Authors:  Chao Zhou; Aneesh Alex; Janarthanan Rasakanthan; Yutao Ma
Journal:  Opt Express       Date:  2013-08-12       Impact factor: 3.894

4.  Clinical assessment of mirror artifacts in spectral-domain optical coherence tomography.

Authors:  Joseph Ho; Dinorah P E Castro; Leonardo C Castro; Yueli Chen; Jonathan Liu; Cynthia Mattox; Chandrasekharan Krishnan; James G Fujimoto; Joel S Schuman; Jay S Duker
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-02-24       Impact factor: 4.799

5.  Visualization of microvasculature by dual-beam phase-resolved Doppler optical coherence tomography.

Authors:  Stefan Zotter; Michael Pircher; Teresa Torzicky; Marco Bonesi; Erich Götzinger; Rainer A Leitgeb; Christoph K Hitzenberger
Journal:  Opt Express       Date:  2011-01-17       Impact factor: 3.894

6.  Line-field parallel swept source MHz OCT for structural and functional retinal imaging.

Authors:  Daniel J Fechtig; Branislav Grajciar; Tilman Schmoll; Cedric Blatter; Rene M Werkmeister; Wolfgang Drexler; Rainer A Leitgeb
Journal:  Biomed Opt Express       Date:  2015-02-04       Impact factor: 3.732

7.  Full-depth spectral domain optical coherence tomography technology insensitive to phase disturbance.

Authors:  Luying Yi; Liqun Sun; Xianshun Ming; Mingli Zou
Journal:  Biomed Opt Express       Date:  2018-10-01       Impact factor: 3.732

8.  Complex conjugate artifact-free adaptive optics optical coherence tomography of in vivo human optic nerve head.

Authors:  Dae Yu Kim; John S Werner; Robert J Zawadzki
Journal:  J Biomed Opt       Date:  2012-12       Impact factor: 3.170

9.  Dual-band Fourier domain optical coherence tomography with depth-related compensations.

Authors:  Miao Zhang; Lixin Ma; Ping Yu
Journal:  Biomed Opt Express       Date:  2013-12-10       Impact factor: 3.732

10.  Master/slave interferometry - ideal tool for coherence revival swept source optical coherence tomography.

Authors:  Adrian Bradu; Sylvain Rivet; Adrian Podoleanu
Journal:  Biomed Opt Express       Date:  2016-06-02       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.