Literature DB >> 27446682

Master/slave interferometry - ideal tool for coherence revival swept source optical coherence tomography.

Adrian Bradu1, Sylvain Rivet2, Adrian Podoleanu1.   

Abstract

In this paper, we demonstrate that the master slave (MS) interferometry method can significantly simplify the practice of coherence revival swept source optical coherence tomography (OCT) technique. Previous implementations of the coherence revival technique required considerable resources on dispersion compensation and data resampling. The total tolerance of the MS method to nonlinear tuning, to dispersion in the interferometer and to dispersion due to the laser cavity, makes the MS ideally suited to the practice of coherence revival. In addition, enhanced versatility is allowed by the MS method in displaying shorter axial range images than that determined by the digital sampling of the data. This brings an immediate improvement in the speed of displaying cross-sectional images at high rates without the need of extra hardware such as graphics processing units or field programmable gate arrays. The long axial range of the coherence revival regime is proven with images of the anterior segment of healthy human volunteers.

Entities:  

Keywords:  (110.4500) Optical coherence tomography; (120.3180) Interferometry; (170.4460) Ophthalmic optics and devices; (200.4740) Optical processing

Year:  2016        PMID: 27446682      PMCID: PMC4948606          DOI: 10.1364/BOE.7.002453

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  36 in total

1.  Removal of a mirror image and enhancement of the signal-to-noise ratio in Fourier-domain optical coherence tomography using an electro-optic phase modulator.

Authors:  Jun Zhang; J Stuart Nelson; Zhongping Chen
Journal:  Opt Lett       Date:  2005-01-15       Impact factor: 3.776

2.  Simultaneous B-M-mode scanning method for real-time full-range Fourier domain optical coherence tomography.

Authors:  Yoshiaki Yasuno; Shuichi Makita; Takashi Endo; Gouki Aoki; Masahide Itoh; Toyohiko Yatagai
Journal:  Appl Opt       Date:  2006-03-10       Impact factor: 1.980

3.  Heterodyne swept-source optical coherence tomography for complete complex conjugate ambiguity removal.

Authors:  Anjul M Davis; Michael A Choma; Joseph A Izatt
Journal:  J Biomed Opt       Date:  2005 Nov-Dec       Impact factor: 3.170

4.  Complex ambiguity-free Fourier domain optical coherence tomography through transverse scanning.

Authors:  Rainer A Leitgeb; Roland Michaely; Theo Lasser; S Chandra Sekhar
Journal:  Opt Lett       Date:  2007-12-01       Impact factor: 3.776

5.  Fourier domain optical coherence tomography with a linear-in-wavenumber spectrometer.

Authors:  Zhilin Hu; Andrew M Rollins
Journal:  Opt Lett       Date:  2007-12-15       Impact factor: 3.776

6.  High-speed complex conjugate resolved retinal spectral domain optical coherence tomography using sinusoidal phase modulation.

Authors:  Yuankai K Tao; Mingtao Zhao; Joseph A Izatt
Journal:  Opt Lett       Date:  2007-10-15       Impact factor: 3.776

7.  Fourier domain optical coherence tomography achieves full range complex imaging in vivo by introducing a carrier frequency during scanning.

Authors:  Ruikang K Wang
Journal:  Phys Med Biol       Date:  2007-09-14       Impact factor: 3.609

8.  Inherent homogenous media dispersion compensation in frequency domain optical coherence tomography by accurate k-sampling.

Authors:  Alexandre R Tumlinson; Bernd Hofer; Amy M Winkler; Boris Povazay; Wolfgang Drexler; Jennifer K Barton
Journal:  Appl Opt       Date:  2008-02-10       Impact factor: 1.980

9.  High-speed phase- and group-delay scanning with a grating-based phase control delay line.

Authors:  G J Tearney; B E Bouma; J G Fujimoto
Journal:  Opt Lett       Date:  1997-12-01       Impact factor: 3.776

10.  Extending the effective imaging range of Fourier-domain optical coherence tomography using a fiber optic switch.

Authors:  Hui Wang; Yinsheng Pan; Andrew M Rollins
Journal:  Opt Lett       Date:  2008-11-15       Impact factor: 3.776

View more
  4 in total

1.  Gabor fusion master slave optical coherence tomography.

Authors:  Ramona Cernat; Adrian Bradu; Niels Møller Israelsen; Ole Bang; Sylvain Rivet; Pearse A Keane; David-Garway Heath; Ranjan Rajendram; Adrian Podoleanu
Journal:  Biomed Opt Express       Date:  2017-01-13       Impact factor: 3.732

2.  Multispectral photoacoustic microscopy and optical coherence tomography using a single supercontinuum source.

Authors:  M Bondu; M J Marques; P M Moselund; G Lall; A Bradu; A Podoleanu
Journal:  Photoacoustics       Date:  2017-11-26

3.  Fast spectrally encoded Mueller optical scanning microscopy.

Authors:  Sylvain Rivet; Matthieu Dubreuil; Adrian Bradu; Yann Le Grand
Journal:  Sci Rep       Date:  2019-03-08       Impact factor: 4.379

4.  Recovering distance information in spectral domain interferometry.

Authors:  Adrian Bradu; Niels Møller Israelsen; Michael Maria; Manuel J Marques; Sylvain Rivet; Thomas Feuchter; Ole Bang; Adrian Podoleanu
Journal:  Sci Rep       Date:  2018-10-18       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.