Literature DB >> 23208216

Complex conjugate artifact-free adaptive optics optical coherence tomography of in vivo human optic nerve head.

Dae Yu Kim1, John S Werner, Robert J Zawadzki.   

Abstract

We acquired in vivo images of the human optic nerve head (ONH) using an adaptive optics-optical coherence tomography (AO-OCT) system. In order to improve imaging of the lamina cribrosa in the ONH with high lateral resolution and sensitivity, we implemented a complex conjugate artifact-free Fourier domain OCT (Fd-OCT) acquisition scheme with a reference arm-based phase shifting method. This allowed positioning of the lamina cribrosa structures near the zero path length difference where AO-OCT imaging achieves highest sensitivity. Implementation of our complex conjugate artifact removal (CCR) method required constant phase shifts between consecutive axial scans (A-scans), generated by continuous beam path-length changes from offsetting the pivot point of the scanning mirror placed in the reference arm. Fourier transform along the transverse axis and a filtering algorithm allowed reconstruction of CCR AO-OCT images. The suppression ratio of the mirror artifact was approximately 22 dB (at 18,000 A-scans per second acquisition speed) with a paperboard test target and an optimum phase-shift value. Finally, we reconstructed the three-dimensional structure of human ONH with enhanced depth range and sensitivity using CCR AO-OCT.

Entities:  

Mesh:

Year:  2012        PMID: 23208216      PMCID: PMC3512164          DOI: 10.1117/1.JBO.17.12.126005

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  28 in total

1.  In vivo human retinal imaging by Fourier domain optical coherence tomography.

Authors:  Maciej Wojtkowski; Rainer Leitgeb; Andrzej Kowalczyk; Tomasz Bajraszewski; Adolf F Fercher
Journal:  J Biomed Opt       Date:  2002-07       Impact factor: 3.170

2.  Comparison of phase-shifting techniques for in vivo full-range, high-speed Fourier-domain optical coherence tomography.

Authors:  Dae Yu Kim; John S Werner; Robert J Zawadzki
Journal:  J Biomed Opt       Date:  2010 Sep-Oct       Impact factor: 3.170

3.  Dynamic focus in optical coherence tomography for retinal imaging.

Authors:  M Pircher; E Götzinger; C K Hitzenberger
Journal:  J Biomed Opt       Date:  2006 Sep-Oct       Impact factor: 3.170

4.  Use of a scanner to modulate spatial interferograms for in vivo full-range Fourier-domain optical coherence tomography.

Authors:  Lin An; Ruikang K Wang
Journal:  Opt Lett       Date:  2007-12-01       Impact factor: 3.776

5.  Dispersion encoded full range frequency domain optical coherence tomography.

Authors:  Bernd Hofer; Boris Povazay; Boris Hermann; Angelika Unterhuber; Gerald Matz; Wolfgang Drexler
Journal:  Opt Express       Date:  2009-01-05       Impact factor: 3.894

6.  Flow velocity estimation by complex ambiguity free joint Spectral and Time domain Optical Coherence Tomography.

Authors:  Maciej Szkulmowski; Ireneusz Grulkowski; Daniel Szlag; Anna Szkulmowska; Andrzej Kowalczyk; Maciej Wojtkowski
Journal:  Opt Express       Date:  2009-08-03       Impact factor: 3.894

7.  Automated analysis of normal and glaucomatous optic nerve head topography images.

Authors:  N V Swindale; G Stjepanovic; A Chin; F S Mikelberg
Journal:  Invest Ophthalmol Vis Sci       Date:  2000-06       Impact factor: 4.799

8.  Reproducibility of measuring lamina cribrosa pore geometry in human and nonhuman primates with in vivo adaptive optics imaging.

Authors:  Kevin M Ivers; Chaohong Li; Nimesh Patel; Nripun Sredar; Xunda Luo; Hope Queener; Ronald S Harwerth; Jason Porter
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-07-23       Impact factor: 4.799

9.  Optic nerve damage in human glaucoma. II. The site of injury and susceptibility to damage.

Authors:  H A Quigley; E M Addicks; W R Green; A E Maumenee
Journal:  Arch Ophthalmol       Date:  1981-04

10.  Integrated adaptive optics optical coherence tomography and adaptive optics scanning laser ophthalmoscope system for simultaneous cellular resolution in vivo retinal imaging.

Authors:  Robert J Zawadzki; Steven M Jones; Suman Pilli; Sandra Balderas-Mata; Dae Yu Kim; Scot S Olivier; John S Werner
Journal:  Biomed Opt Express       Date:  2011-05-24       Impact factor: 3.732

View more
  3 in total

Review 1.  In vivo imaging methods to assess glaucomatous optic neuropathy.

Authors:  Brad Fortune
Journal:  Exp Eye Res       Date:  2015-06-03       Impact factor: 3.467

Review 2.  The fundus photo has met its match: optical coherence tomography and adaptive optics ophthalmoscopy are here to stay.

Authors:  Jessica I W Morgan
Journal:  Ophthalmic Physiol Opt       Date:  2016-05       Impact factor: 3.117

Review 3.  A Review of Adaptive Optics Optical Coherence Tomography: Technical Advances, Scientific Applications, and the Future.

Authors:  Ravi S Jonnal; Omer P Kocaoglu; Robert J Zawadzki; Zhuolin Liu; Donald T Miller; John S Werner
Journal:  Invest Ophthalmol Vis Sci       Date:  2016-07-01       Impact factor: 4.799

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.