Literature DB >> 16567776

The effect of the diameter of metal-on-metal bearings on systemic exposure to cobalt and chromium.

J Daniel1, H Ziaee, A Salama, C Pradhan, D J W McMinn.   

Abstract

The recent resurgence in the use of metal-on-metal bearings has led to fresh concerns over metal wear and elevated systemic levels of metal ions. In order to establish if bearing diameter influences the release of metal ions, we compared the whole blood levels of cobalt and chromium (at one year) and the urinary cobalt and chromium output (at one to three and four to six years) following either a 50 mm or 54 mm Birmingham hip resurfacing or a 28 mm Metasul total hip replacement. The whole blood concentrations and daily output of cobalt and chromium in these time periods for both bearings were in the same range and without significant difference.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16567776     DOI: 10.1302/0301-620X.88B4.17355

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  11 in total

Review 1.  [Implant wear and aseptic loosening. An overview].

Authors:  C Kaddick; I Catelas; P H Pennekamp; M A Wimmer
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

2.  Metal-on-metal hip prostheses: correlation between debris in the synovial fluid and levels of cobalt and chromium ions in the bloodstream.

Authors:  Dalila De Pasquale; Susanna Stea; Stefano Squarzoni; Barbara Bordini; Marilina Amabile; Simona Catalani; Pietro Apostoli; Aldo Toni
Journal:  Int Orthop       Date:  2014-03       Impact factor: 3.075

3.  What are the risks accompanying the reduced wear benefit of low-clearance hip resurfacing?

Authors:  Joseph Daniel; Hena Ziaee; Amir Kamali; Chandra Pradhan; Derek McMinn
Journal:  Clin Orthop Relat Res       Date:  2012-07-24       Impact factor: 4.176

4.  Femoral head size does not affect ion values in metal-on-metal total hips.

Authors:  Mitchell Bernstein; Alan Walsh; Alain Petit; David J Zukor; Olga L Huk; John Antoniou
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

5.  Early markers of nephrotoxicity in patients with metal-on-metal hip arthroplasty.

Authors:  Massimo Corradi; Joseph Daniel; Hena Ziaee; Rossella Alinovi; Antonio Mutti; Derek J W McMinn
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

6.  What should I expect from my recalled Adept Hip Resurfacing?

Authors:  Matteo Cadossi; Silvio Terrando; Andrea Sambri; Giuseppe Tedesco; Antonio Mazzotti; Barbara Bordini; Dalila De Pasquale; Cesare Faldini
Journal:  Musculoskelet Surg       Date:  2017-04-27

7.  Does ion release differ between hip resurfacing and metal-on-metal THA?

Authors:  Antonio Moroni; Lucia Savarino; Matteo Cadossi; Nicola Baldini; Sandro Giannini
Journal:  Clin Orthop Relat Res       Date:  2008-01-09       Impact factor: 4.176

8.  Significance of Elevated Blood Metal Ion Levels in Patients with Metal-on-Metal Prostheses: An Evaluation of Oxidative Stress Markers.

Authors:  Cathy Tkaczyk; Alain Petit; John Antoniou; David J Zukor; Maryam Tabrizian; Olga L Huk
Journal:  Open Orthop J       Date:  2010-07-02

Review 9.  Chromium and cobalt ion concentrations in blood and serum following various types of metal-on-metal hip arthroplasties: a literature overview.

Authors:  Christopher Jantzen; Henrik L Jørgensen; Benn R Duus; Sune L Sporring; Jes B Lauritzen
Journal:  Acta Orthop       Date:  2013-04-18       Impact factor: 3.717

10.  Release of chromium from orthopaedic arthroplasties.

Authors:  G A Afolaranmi; J Tettey; R M D Meek; M H Grant
Journal:  Open Orthop J       Date:  2008-01-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.