Many orthopaedic implants are composed of alloys containing chromium. Of particular relevance is the increasing number of Cobalt Chromium bearing arthroplasies being inserted into young patients with osteoarthritis. Such implants will release chromium ions. These patients will be exposed to the released chromium for over 50 years in some cases. The subsequent chromium ion metabolism and redistribution in fluid and tissue compartments is complex. In addition, the potential biological effects of chromium are also controversial, including DNA and chromosomal damage, reduction in CD8 lymphocyte levels and possible hypersensitivity reactions (ALVAL). The establishment of these issues and the measurement of chromium in biological fluids is the subject of this review.Entities:
Year: 2008 PMID: 19461924 PMCID: PMC2685051 DOI: 10.2174/1874325000802010010
Source DB: PubMed Journal: Open Orthop J ISSN: 1874-3250
Compositional Limits % (m/m) of Elements in the Main Alloys Used in Orthopaedic Prostheses (British Standard Metallic Materials for Surgical Implants http://bsonline.bsi-global.com) [14]
| Group | C | Si | Mn | P | S | N | Cr | Co | Mo | Ni | Cu | Fe | Ti | H | O | Al | V | W | Be | Nb | Ta |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ISO 5832-1 Wrought stainless steel | 0.03 | 1.0 | 2.0 | 0.025 | 0.01 | 0.1 | 17-19 | - | 2.25-3.5 | 13-15 | 0.5 | Bal | - | - | - | - | - | - | - | - | - |
| ISO 5832-2 Unalloyed titanium | 0.03 | - | - | - | - | 0.012 | - | - | - | - | - | 0.1 | Bal | 0.0125 | 0.1 | - | - | - | - | - | - |
| ISO 5832-3 Wrought Ti 6-Al-4 V alloy | 0.08 | - | - | - | - | 0.05 | - | - | - | - | - | 0.3 | Bal | .015 | 0.2 | 5.5-6.75 | 3.5-4.5 | - | - | - | - |
| ISO 5832-4 Co-Cr-Mo casting alloy | 0.35 | 1.0 | 1.0 | - | - | - | 26.5-30 | Bal | 4.5-7.0 | 1.0 | - | 1.0 | - | - | - | - | - | - | - | - | - |
| ISO 5832-5 Co-Cr-W-Ni alloy | 0.15 | 1.0 | 2.0 | - | - | - | 19-21 | Bal | - | 9-11 | - | 3.0 | - | - | - | - | - | 14-16 | - | - | - |
| ISO 5832-6 Wrought Co-Ni-Cr-Mo alloy | 0.025 | 0.15 | 0.15 | 0.015 | 0.01 | - | 19-21 | Bal | 9-10.5 | 33-37 | -- | 1.0 | 1.0 | - | - | - | - | - | - | - | - |
| ISO 5832-7 Co-Cr-Ni-Mo-Fe alloy | 0.15 | 1 | 1-2.5 | 0.015 | 0.015 | - | 18.5-21.5 | 39-42 | 6.5-8.0 | 14-18 | - | Bal | 0.5-3.5 | - | - | - | - | - | 0.001 | - | - |
| ISO 5832-8 Wrought Co-Ni-Cr-Mo-T-Fe alloy | 0.05 | 0.5 | 1.0 | - | 0.01 | - | 18-22 | Bal | 3-4.0 | 15-25 | - | 4-6.0 | - | - | - | - | - | 3-4.0 | - | - | - |
| ISO 5832-9 High nitrogen stainless steel | 0.08 | 0.075 | 2-4.25 | 0.025 | 0.01 | 0.25-0.5 | 19.5-22 | - | 2-3.0 | 9-11 | 0.25 | Bal | - | - | - | - | - | - | - | 0.25-0.8 | - |
| ISO 5832-10 Wrought Ti 5-Al, 2,5 Fe alloy | 0.08 | - | - | - | - | 0.05 | - | - | - | - | 2-3.0 | Bal | 0.015 | 0.2 | 4.5-5.5 | 4.5-5.5 | - | - | - | - | |
| ISO 5832-11 Wrought Ti 6- Al, 7-Nb alloy | 0.08 | - | - | - | - | 0.05 | - | - | - | 0.25 | Bal | 0.009 | 0.2 | 5.5-6.5 | - | - | - | 6.5-7.5 | 0.5 | ||
| ISO 5832-12 Wrought Co-Cr-Mo alloy | 0.35 | 1 | 1 | - | - | 0.25 | 26-30 | Bal | 5-7 | 1 | - | 0.75 | - | - | - | - | - | - | - | - |
Carbon (C), Silicon (Si), Manganese (Mn), Phosphorus (P), Sulfur (S), Nitrogen (N), Chromium (Cr), Cobalt (Co), Molybdenum (Mo), Nickel (Ni), Copper (Cu), Iron (Fe), Titanium (Ti), Hydrogen (H), Oxygen (O), Aluminum (Al), Vanadium (V), Tungsten (W), Beryllium (Be), Niobium (Nb), Tantalum (Ta), Balance (Bal).
Concentrations of Chromium µg/L in the Biological Samples of Patients Following Ion Release from Different Models of Metal-On-Metal Orthopaedic Implants
| Study | Follow Up Years | Model | Serum | Control (Serum) |
|---|---|---|---|---|
| [ | 2.5 | Co-Cr | 0.10 | 0.1 |
| [ | > 1 | Co-Cr | Plasma RBC 8.31 14.83 | Plasma & RBC 0.01 |
| [ | 25 | Mckee -Farrar | 1.28 | 0.14 |
| 1 | Surface replacement | 3.86 | 0.14 | |
| [ | 2.2 | Metasul | 1.72 | 0.25 |
| [ | 0.25 | Conserve plus | 1.88 | 0.08 |
| 0.5 | 2.02 | |||
| 1 | 1.80 | |||
| [ | 1.33 | Ultima (CoCrMo) | 0.99 | 0.26 |
| 1.33 | Ultima (CoCrMo) resurfaced | 2.77 | 0.26 | |
| [ | Imm postop | metasul | 7.78 | |
| 0.25-0.5 | 16.79 | |||
| 1-1.25 | 34.75 | |||
| 3 | 48.04 | |||
| 3.5-4 | 25.62 | 0.21 | ||
| [ | Imm postop | Sikomet | 14.27 | 0.21 |
| 0.25-0.5 | 22.19 | |||
| 1-1.25 | 30.81 | |||
| 3 | 22.24 | |||
| 3.5-4 | 36.35 | |||
| [ | 2 | CoCrMo | 2.50 | 1.09 |
| [ | 0.5 | metasul | 0.73 | |
| 1 | 1.05 | |||
| 1.5 | 1.37 | |||
| [ | 1 | Metasul THR | 1.7 | |
| 1 | BHR | 2.4 | ||
| [ | 0.5-3.5 | M/M resurfacing | 1.78 | 0.28 |
| [ | 1.28 | Conserve Plus | 2.88 | 1.47 |
| [ | 6 | M/M | 3.48 | 0.92 |
| [ | 4.5 | Metasul | 2.1 | 0.28 |
| [ | 5 (retrospective) | Sikomet | 1.31 | 0.3 |
| 0.4 (Prospective) | Sikomet | 1.12 | 0.67 | |
| 1.6 (Prospective) | Sikomet | 1.30 | 0.67 | |
| 0.41(Revision) | Sikomet | 0.63 | Prior to revision 0.79 | |
| 1.28 (Revision) | Sikomet | 0.45 | Prior to revision 0.79 |
Serum (mean values)
Erythrocyte (median Values)
whole blood (mean values).