Literature DB >> 16541227

Accuracy and complications in computed tomography fluoroscopy-guided needle biopsies of lung masses.

Siri Lagethon Heck1, Peter Blom, Audun Berstad.   

Abstract

The aim of this study was to determine the diagnostic accuracy and frequency of complications of lung biopsy procedures with or without CTF guidance of needle insertion. Records and images of 99 consecutive percutaneous coaxial cutting needle lung biopsy procedures performed on 85 patients were reviewed retrospectively. Fifty-seven and 42 procedures had been done with and without CTF guidance, respectively. Histological results were compared to diagnosis after surgery or after a follow-up period of 12 months. Diagnostic accuracy and the occurrence of pneumothorax and/or bleeding related to the procedures were registered. The level of accuracy of the diagnosis was comparable. The diagnostic accuracy was 96% (50/52) and 95% (34/36) sensitivity 95% (35/37) and 93% (26/28), specificity 100% (15/15) and 100% (8/8) with CTF and conventional CT techniques, respectively. There were fewer post procedure pneumothoraces using the CTF than conventional technique [26% (15/57) vs. 38% (16/42)], but the difference was not statistically significant (P = 0.274). The insertion of a chest tube was required in only one (2%) procedure using the CTF technique, while this was needed in four (10%) using the conventional technique. Small or large hemorrhages occurred in 23% of the procedures, with no apparent difference between the two groups. In conclusion, CTF-guided biopsy of lung lesions provides high diagnostic accuracy, comparable to that of conventional CT-guided procedures, with a low rate of complications, even for small tumors.

Entities:  

Mesh:

Year:  2006        PMID: 16541227     DOI: 10.1007/s00330-006-0152-2

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  25 in total

1.  CT fluoroscopy-guided abdominal interventions: techniques, results, and radiation exposure.

Authors:  S G Silverman; K Tuncali; D F Adams; R D Nawfel; K H Zou; P F Judy
Journal:  Radiology       Date:  1999-09       Impact factor: 11.105

2.  Computed tomographic fluoroscopy-guided transthoracic needle biopsy for diagnosis of pulmonary nodules.

Authors:  T Hirose; K Mori; S Machida; K Tominaga; K Yokoi; M Adachi
Journal:  Jpn J Clin Oncol       Date:  2000-06       Impact factor: 3.019

3.  Management of pneumothorax after percutaneous CT-guided lung biopsy.

Authors:  Takuji Yamagami; Toshiyuki Nakamura; Shigeharu Iida; Takeharu Kato; Tsunehiko Nishimura
Journal:  Chest       Date:  2002-04       Impact factor: 9.410

4.  What constitutes effective management of pneumothorax after CT-guided needle biopsy of the lung?

Authors:  Linda B Haramati; Galit Aviram
Journal:  Chest       Date:  2002-04       Impact factor: 9.410

5.  Combining fine-needle aspiration and core biopsy under CT fluoroscopy guidance: a better way to treat patients with lung nodules?

Authors:  Takuji Yamagami; Shigeharu Iida; Takeharu Kato; Osamu Tanaka; Tsunehiko Nishimura
Journal:  AJR Am J Roentgenol       Date:  2003-03       Impact factor: 3.959

6.  Benefits and safety of CT fluoroscopy in interventional radiologic procedures.

Authors:  S K Carlson; C E Bender; K L Classic; F E Zink; J P Quam; E M Ward; A L Oberg
Journal:  Radiology       Date:  2001-05       Impact factor: 11.105

7.  The incidence and the risk of pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy: the angle of the needle trajectory is a novel predictor.

Authors:  Hisashi Saji; Haruhiko Nakamura; Takaaki Tsuchida; Masahiro Tsuboi; Norihiko Kawate; Chimori Konaka; Harubumi Kato
Journal:  Chest       Date:  2002-05       Impact factor: 9.410

8.  Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures.

Authors:  Kee-Min Yeow; Pei-Kwei Tsay; Yun-Chung Cheung; Kar-Wai Lui; Kuang-Tse Pan; Andy Shau-Bin Chou
Journal:  J Vasc Interv Radiol       Date:  2003-05       Impact factor: 3.464

9.  Factors associated with pneumothorax and pneumothorax requiring treatment after percutaneous lung biopsy in 443 consecutive patients.

Authors:  Anne M Covey; Ripal Gandhi; Lynn A Brody; George Getrajdman; Howard T Thaler; Karen T Brown
Journal:  J Vasc Interv Radiol       Date:  2004-05       Impact factor: 3.464

10.  Factors influencing accuracy of CT-guided percutaneous biopsies of pulmonary lesions.

Authors:  Michel Montaudon; Valerie Latrabe; Antoine Pariente; Olivier Corneloup; Hugues Begueret; François Laurent
Journal:  Eur Radiol       Date:  2004-02-13       Impact factor: 5.315

View more
  32 in total

1.  Transthoracic fine-needle aspiration biopsy of the lungs using a C-arm cone-beam CT system: diagnostic accuracy and post-procedural complications.

Authors:  W J Lee; S Chong; J S Seo; H J Shim
Journal:  Br J Radiol       Date:  2011-10-18       Impact factor: 3.039

2.  Dynamic telecytologic evaluation of imprint cytology samples from CT-guided lung biopsies: a feasibility study.

Authors:  Helmut Prosch; Elisabeth Hoffmann; Klaus Bernhardt; Johann Schalleschak; Ewald Schober; Marcel Rowhani; Michael Weber; Gerhard Mostbeck
Journal:  Eur Radiol       Date:  2011-05-08       Impact factor: 5.315

3.  Transthoracic needle biopsy using a C-arm cone-beam CT system: diagnostic accuracy and safety.

Authors:  M J Choi; Y Kim; Y S Hong; S S Shim; S M Lim; J K Lee
Journal:  Br J Radiol       Date:  2011-07-26       Impact factor: 3.039

4.  CT fluoroscopy-guided preoperative short hook wire placement for small pulmonary lesions: evaluation of safety and identification of risk factors for pneumothorax.

Authors:  Toshihiro Iguchi; Takao Hiraki; Hideo Gobara; Hiroyasu Fujiwara; Yusuke Matsui; Shinichiro Miyoshi; Susumu Kanazawa
Journal:  Eur Radiol       Date:  2015-05-20       Impact factor: 5.315

Review 5.  Common complications of nonvascular percutaneous thoracic interventions: diagnosis and management.

Authors:  Azzam Khankan; Shireen Sirhan; Fadi Aris
Journal:  Semin Intervent Radiol       Date:  2015-06       Impact factor: 1.513

6.  Diagnostic accuracy and complication rates of percutaneous CT-guided coaxial needle biopsy of pulmonary lesions.

Authors:  Vesna Sarajlic; Sanela Vesnic; Dalma Udovicic-Gagula; Haris Kuric; Okan Akhan
Journal:  Diagn Interv Radiol       Date:  2021-07       Impact factor: 2.630

7.  Percutaneous transthoracic needle biopsy of small (≤ 1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidance.

Authors:  Ji Yung Choo; Chang Min Park; Nyoung Keun Lee; Sang Min Lee; Hyun-Ju Lee; Jin Mo Goo
Journal:  Eur Radiol       Date:  2012-09-14       Impact factor: 5.315

Review 8.  Percutaneous lung biopsy: technique, efficacy, and complications.

Authors:  Ronald S Winokur; Bradley B Pua; Brian W Sullivan; David C Madoff
Journal:  Semin Intervent Radiol       Date:  2013-06       Impact factor: 1.513

9.  Percutaneous transthoracic localization of pulmonary nodules under C-arm cone-beam CT virtual navigation guidance.

Authors:  Tae Ho Kim; Chang Min Park; Sang Min Lee; H Page McAdams; Young Tae Kim; Jin Mo Goo
Journal:  Diagn Interv Radiol       Date:  2016 May-Jun       Impact factor: 2.630

Review 10.  Pleural controversies: image guided biopsy vs. thoracoscopy for undiagnosed pleural effusions?

Authors:  Giles Dixon; Duneesha de Fonseka; Nick Maskell
Journal:  J Thorac Dis       Date:  2015-06       Impact factor: 2.895

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.