Literature DB >> 11948047

Management of pneumothorax after percutaneous CT-guided lung biopsy.

Takuji Yamagami1, Toshiyuki Nakamura, Shigeharu Iida, Takeharu Kato, Tsunehiko Nishimura.   

Abstract

OBJECTIVES: To evaluate the efficacy of simple aspiration of air from the pleural space to prevent increased pneumothorax and to avoid chest tube placement in cases of pneumothorax following CT-guided lung biopsy.
DESIGN: Observational.
MATERIALS AND METHODS: One hundred thirty-four consecutive percutaneous needle lung biopsies using real-time CT fluoroscopy guidance formed the basis of our study. All patients that demonstrated moderate or severe pneumothorax on postbiopsy chest CT images underwent percutaneous manual aspiration regardless of symptoms while on the CT scanner table. Correlation between the incidence of pneumothorax after biopsy and many factors (i.e., gender, age, number of pleural passes, presence of emphysema, lesion size, and lesion depth) were determined, and management of each case of biopsy-induced pneumothorax was reviewed.
RESULTS: Postbiopsy pneumothorax occurred in 46 of 134 procedures (34.3%). Twenty of the 46 patients were treated by manual aspiration, while 26 patients were simply observed. In 43 of the 46 pneumothoraces (93.5%), the pneumothorax resolved completely on follow-up chest radiographs without requiring tube placement. Only three patients (2.2% of the entire series; 6.5% of those who had pneumothorax develop) required chest tube placement. The risk of pneumothorax significantly increased with lesion size and depth.
CONCLUSION: Results of our nonprospective, nonrandomized study suggest that percutaneous manual aspiration of biopsy-induced pneumothorax performed immediately after biopsy may prevent progressive pneumothorax and subsequent chest tube placement.

Entities:  

Mesh:

Year:  2002        PMID: 11948047     DOI: 10.1378/chest.121.4.1159

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  29 in total

1.  Transthoracic needle biopsy.

Authors:  Katherine R Birchard
Journal:  Semin Intervent Radiol       Date:  2011-03       Impact factor: 1.513

2.  Is the rapid needle-out patient-rollover approach after CT-guided lung biopsy really effective for pneumothorax prevention?

Authors:  Zafar Neyaz; Namita Mohindra
Journal:  J Thorac Dis       Date:  2015-09       Impact factor: 2.895

3.  Safer lung biopsy techniques: fewer patients with pneumothorax, fewer chest tube insertions.

Authors:  Kamran Ahrar
Journal:  J Thorac Dis       Date:  2015-10       Impact factor: 2.895

4.  Accuracy and complications in computed tomography fluoroscopy-guided needle biopsies of lung masses.

Authors:  Siri Lagethon Heck; Peter Blom; Audun Berstad
Journal:  Eur Radiol       Date:  2006-03-16       Impact factor: 5.315

Review 5.  Trans-thoracic biopsy of lung lesions: FNAB or CNB? Our experience and review of the literature.

Authors:  Emanuela Capalbo; Michela Peli; Maria Lovisatti; Maria Cosentino; Paola Mariani; Eisabetta Berti; Maurizio Cariati
Journal:  Radiol Med       Date:  2013-12-03       Impact factor: 3.469

6.  Pneumothorax: a common complication of CT-guided transthoracic needle lung biopsy.

Authors:  Subhash Chandra; Dipti Agarwal; Vikash Singh; Anant Mohan; Randeep Guleria
Journal:  BMJ Case Rep       Date:  2009-05-08

7.  Percutaneous transthoracic needle biopsy: special considerations and techniques used in lung transplant recipients.

Authors:  Amanda B Wallace; Robert D Suh
Journal:  Semin Intervent Radiol       Date:  2004-12       Impact factor: 1.513

8.  Comparison of fully automated and semi-automated biopsy needles for lung biopsy under CT fluoroscopic guidance.

Authors:  R Yoshimatsu; T Yamagami; O Tanaka; H Miura; T Tanaka; T Suzuki; T Nishimura
Journal:  Br J Radiol       Date:  2011-08-09       Impact factor: 3.039

Review 9.  Common complications of nonvascular percutaneous thoracic interventions: diagnosis and management.

Authors:  Azzam Khankan; Shireen Sirhan; Fadi Aris
Journal:  Semin Intervent Radiol       Date:  2015-06       Impact factor: 1.513

10.  Diagnostic performance of percutaneous lung biopsy using automated biopsy needles under CT-fluoroscopic guidance for ground-glass opacity lesions.

Authors:  T Yamagami; R Yoshimatsu; H Miura; K Yamada; A Takahata; T Matsumoto; T Hasebe
Journal:  Br J Radiol       Date:  2013-02       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.