Literature DB >> 16503155

Novel linear ion trap mass analyzer composed of four planar electrodes.

Yishu Song1, Guangxiang Wu1, Qingyu Song1, R Graham Cooks2, Zheng Ouyang3, Wolfgang R Plass4.   

Abstract

A novel linear ion trap mass analyzer was developed using just four elongated planar electrodes, mounted in parallel, and employing an RF potential for ion trapping in the radial and axial directions. Mass analysis was achieved using the mass-selective instability scan with ion ejection in the radial direction. The performance of this new device was characterized in comparison with the 6-electrode rectilinear ion trap (RIT) from which it is derived. The 4-electrode trap gives optimum performance in an asymmetric geometry, just like the original optimized 6-electrode RIT. The strong RF fringing fields at the ends of the RF rods account for axial ion trapping without use of extra electrodes or an axial DC voltage. Field calculations and simulations have been carried out to study the trapping potential inside RITs with various configurations. Demonstrated capabilities include analysis of externally injected ions with mass resolution in excess of 1000 and a mass/charge range of 650 Th as well as tandem mass spectrometry capabilities. The geometric simplicity and performance characteristics of the 4-electrode RIT make it particularly attractive in the development of next generation miniaturized mass spectrometers.

Year:  2006        PMID: 16503155     DOI: 10.1016/j.jasms.2005.12.014

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  13 in total

1.  A two-dimensional quadrupole ion trap mass spectrometer.

Authors:  Jae C Schwartz; Michael W Senko; John E P Syka
Journal:  J Am Soc Mass Spectrom       Date:  2002-06       Impact factor: 3.109

2.  High-throughput miniature cylindrical ion trap array mass spectrometer.

Authors:  Amy M Tabert; Jens Griep-Raming; Andrew J Guymon; R Graham Cooks
Journal:  Anal Chem       Date:  2003-11-01       Impact factor: 6.986

3.  Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry.

Authors:  John E P Syka; Joshua J Coon; Melanie J Schroeder; Jeffrey Shabanowitz; Donald F Hunt
Journal:  Proc Natl Acad Sci U S A       Date:  2004-06-21       Impact factor: 11.205

4.  Rectilinear ion trap: concepts, calculations, and analytical performance of a new mass analyzer.

Authors:  Zheng Ouyang; Guangxiang Wu; Yishu Song; Hongyan Li; Wolfgang R Plass; R Graham Cooks
Journal:  Anal Chem       Date:  2004-08-15       Impact factor: 6.986

5.  Linear ion traps in mass spectrometry.

Authors:  Donald J Douglas; Aaron J Frank; Dunmin Mao
Journal:  Mass Spectrom Rev       Date:  2005 Jan-Feb       Impact factor: 10.946

6.  Electron-transfer ion/ion reactions of doubly protonated peptides: effect of elevated bath gas temperature.

Authors:  Sharon J Pitteri; Paul A Chrisman; Scott A McLuckey
Journal:  Anal Chem       Date:  2005-09-01       Impact factor: 6.986

7.  Co-occurrence of boundary and resonance ejection in a multiplexed rectilinear ion trap mass spectrometer.

Authors:  Amy M Tabert; Michael P Goodwin; R Graham Cooks
Journal:  J Am Soc Mass Spectrom       Date:  2005-12-15       Impact factor: 3.109

8.  High-throughput mass spectrometer using atmospheric pressure ionization and a cylindrical ion trap array.

Authors:  Alexander S Misharin; Brian C Laughlin; Andrey Vilkov; Zoltán Takáts; Zheng Ouyang; R Graham Cooks
Journal:  Anal Chem       Date:  2005-01-15       Impact factor: 6.986

9.  Rectilinear ion trap mass spectrometer with atmospheric pressure interface and electrospray ionization source.

Authors:  Qingyu Song; Sameer Kothari; Michael A Senko; Jae C Schwartz; Jonathan W Amy; George C Stafford; R Graham Cooks; Zheng Ouyang
Journal:  Anal Chem       Date:  2006-02-01       Impact factor: 6.986

10.  Stored waveform inverse Fourier transform axial excitation/ejection for quadrupole ion trap mass spectrometry.

Authors:  S Guan; A G Marshall
Journal:  Anal Chem       Date:  1993-05-01       Impact factor: 6.986

View more
  5 in total

Review 1.  Miniature and Fieldable Mass Spectrometers: Recent Advances.

Authors:  Dalton T Snyder; Christopher J Pulliam; Zheng Ouyang; R Graham Cooks
Journal:  Anal Chem       Date:  2015-10-21       Impact factor: 6.986

2.  Computer simulation of the gap-tripole ion trap with linear injection, 3D ion accumulation, and versatile packet ejection.

Authors:  Gary A Salazar; Tsutomu Masujima
Journal:  J Am Soc Mass Spectrom       Date:  2008-06-11       Impact factor: 3.109

3.  Extending the Ion Capacity of a Linear Ion Trap Using Nonlinear Radio Frequency Fields.

Authors:  Mircea Guna
Journal:  J Am Soc Mass Spectrom       Date:  2015-07-16       Impact factor: 3.109

4.  Electrospray ionisation-cleavable tandem nucleic acid mass tag-peptide nucleic acid conjugates: synthesis and applications to quantitative genomic analysis using electrospray ionisation-MS/MS.

Authors:  Andrew Thompson; Mark Prescott; Noorhan Chelebi; John Smith; Tom Brown; Günter Schmidt
Journal:  Nucleic Acids Res       Date:  2007-01-26       Impact factor: 16.971

5.  Current literature in mass spectrometry.

Authors: 
Journal:  J Mass Spectrom       Date:  2007-01       Impact factor: 1.982

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.