High-throughput mass spectrometer using atmospheric pressure ionization and a cylindrical ion trap array.

Alexander S Misharin1, Brian C Laughlin, Andrey Vilkov, Zoltán Takáts, Zheng Ouyang, R Graham Cooks.   

Abstract

The analytical performance of an atmospheric pressure sampling, multiple-channel, high-throughput mass spectrometer was investigated using samples of a variety of types. The instrument, based on an array of cylindrical ion traps, was built with four independent channels and here is operated using two fully multiplexed channels (sources, ion optics, ion traps, detectors) capable of analyzing different samples simultaneously. Both channels of the instrument were incorporated within the same vacuum system and operated using a common set of control electronics. A multichannel electrospray ionization source was assembled and used to introduce samples including solutions of organic compounds, peptides, and proteins simultaneously into the instrument in a high-throughput fashion. Cross-talk between the channels of the instrument occurred in the detection system and could be minimized to 1-2% using shielding between detector channels. In this initial implementation of the instrumentation, an upper mass/charge limit of approximately 1300 Th was observed (+13 charge state of myoglobin) and unit mass/charge resolution was achieved to approximately 800 Th. The rather limited dynamic range (2-3 orders of magnitude for low-concentration analytes) is due to cross-talk contributions from more concentrated species introduced into a different channel. Analysis of mixtures of alkylamines and peptides is demonstrated, but analysis of mixtures with a wide spread in mass/charge ratios was not possible due to mass discrimination in the ion optics. Further refinement of the vacuum system and ion optics will allow the addition of more channels of parallel mass analysis and facilitate applications in fields such as proteomics and metabolomics.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15649041     DOI: 10.1021/ac048983w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Analysis of lipids from crude lung tissue extracts by desorption electrospray ionization mass spectrometry and pattern recognition.

Authors:  Franco Basile; Tamara Sibray; John T Belisle; Richard A Bowen
Journal:  Anal Biochem       Date:  2010-09-22       Impact factor: 3.365

2.  Novel linear ion trap mass analyzer composed of four planar electrodes.

Authors:  Yishu Song; Guangxiang Wu; Qingyu Song; R Graham Cooks; Zheng Ouyang; Wolfgang R Plass
Journal:  J Am Soc Mass Spectrom       Date:  2006-02-28       Impact factor: 3.109

3.  Experimental Observation of the Effects of Translational and Rotational Electrode Misalignment on a Planar Linear Ion Trap Mass Spectrometer.

Authors:  Yuan Tian; Trevor K Decker; Joshua S McClellan; Qinghao Wu; Abraham De la Cruz; Aaron R Hawkins; Daniel E Austin
Journal:  J Am Soc Mass Spectrom       Date:  2018-04-05       Impact factor: 3.109

4.  Ion sponge: a 3-dimentional array of quadrupole ion traps for trapping and mass-selectively processing ions in gas phase.

Authors:  Wei Xu; Linfan Li; Xiaoyu Zhou; Zheng Ouyang
Journal:  Anal Chem       Date:  2014-04-28       Impact factor: 6.986

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.