Literature DB >> 26178741

Extending the Ion Capacity of a Linear Ion Trap Using Nonlinear Radio Frequency Fields.

Mircea Guna1.   

Abstract

Mass selective axial ejection (MSAE) from a low pressure linear ion trap (LIT) is investigated in the presence of added auxiliary nonlinear radio frequency (rf) fields. Nonlinear rf fields allow ions to be ejected with high sensitivity at large excitation amplitudes and reduced deleterious effects of space charge. These permit the operation of the LIT at ion populations considerably larger than the space charge limit usually observed in the absence of the nonlinear fields while maintaining good spectral resolution and mass accuracy. Experimental data show that the greater the strength of the nonlinear field, the less the effects of space charge on mass assignment and peak width. The only deleterious effect is a slight broadening of the mass spectral peaks at the highest values of added nonlinear fields used. Graphical Abstract ᅟ.

Keywords:  Ion capacity; Linear ion trap; Mass accuracy; Mass selective axial ejection; Nonlinear fields; Space charge

Year:  2015        PMID: 26178741     DOI: 10.1007/s13361-015-1227-6

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  12 in total

1.  A two-dimensional quadrupole ion trap mass spectrometer.

Authors:  Jae C Schwartz; Michael W Senko; John E P Syka
Journal:  J Am Soc Mass Spectrom       Date:  2002-06       Impact factor: 3.109

2.  Mass selective axial ion ejection from a linear quadrupole ion trap.

Authors:  F A Londry; James W Hager
Journal:  J Am Soc Mass Spectrom       Date:  2003-10       Impact factor: 3.109

3.  Space-charge effects with mass-selective axial ejection from a linear quadrupole ion trap.

Authors:  Hui Qiao; Cong Gao; Dunmin Mao; Nikolai Konenkov; D J Douglas
Journal:  Rapid Commun Mass Spectrom       Date:  2011-12-15       Impact factor: 2.419

4.  Novel linear ion trap mass analyzer composed of four planar electrodes.

Authors:  Yishu Song; Guangxiang Wu; Qingyu Song; R Graham Cooks; Zheng Ouyang; Wolfgang R Plass
Journal:  J Am Soc Mass Spectrom       Date:  2006-02-28       Impact factor: 3.109

5.  Space charge induced nonlinear effects in quadrupole ion traps.

Authors:  Dan Guo; Yuzhuo Wang; Xingchuang Xiong; Hua Zhang; Xiaohua Zhang; Tao Yuan; Xiang Fang; Wei Xu
Journal:  J Am Soc Mass Spectrom       Date:  2014-01-03       Impact factor: 3.109

6.  MS/MS of ions in a low pressure linear ion trap using a pulsed gas.

Authors:  Bruce A Collings; Matthew A Romaschin
Journal:  J Am Soc Mass Spectrom       Date:  2009-05-20       Impact factor: 3.109

7.  Collective oscillations of stored ions.

Authors: 
Journal:  Phys Rev A Gen Phys       Date:  1987-10-01

8.  Tandem ion trap design with enhanced mass analysis capabilities for large populations of ions.

Authors:  Mircea Guna; Frank A Londry
Journal:  Anal Chem       Date:  2011-07-27       Impact factor: 6.986

9.  Product ion scanning using a Q-q-Q linear ion trap (Q TRAP) mass spectrometer.

Authors:  James W Hager; J C Yves Le Blanc
Journal:  Rapid Commun Mass Spectrom       Date:  2003       Impact factor: 2.419

10.  Mass selective axial ion ejection from linear quadrupoles with added octopole fields.

Authors:  Annie Moradian; D J Douglas
Journal:  J Am Soc Mass Spectrom       Date:  2007-11-12       Impact factor: 3.109

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.