Literature DB >> 14588002

High-throughput miniature cylindrical ion trap array mass spectrometer.

Amy M Tabert1, Jens Griep-Raming, Andrew J Guymon, R Graham Cooks.   

Abstract

A fully multiplexed cylindrical ion trap (CIT) array mass spectrometer with four parallel ion source/mass analyzer/detector channels has been built to allow simultaneous high-throughput analysis of multiple samples. A multielement external chemical ionization/electron ionization source was coupled to a parallel array of CITs each of equal size (internal radius 2.5 mm), and the signal was recorded using an array of four miniature (2-mm inner diameter) electron multipliers. Using external electron ionization, the spectra of four separate samples were recorded simultaneously in real time using a four-channel preamplifier system and a data acquisition program written using LabVIEW software. These experiments mark the first demonstration of externally generated ions being successfully trapped in a miniature CIT mass analyzer. The instrument currently provides mass/charge range of approximately m/z 50-500. Average peak width is m/z 0.3, corresponding to a resolution of 1000 at m/z 300. The four-channel mass spectrometer is housed in a single vacuum manifold and operated with a single set of control electronics. The modular design of this instrument allows scale-up to many more channels of analysis for future applications in the areas of industrial process monitoring and combinatorial analysis and in the fields of proteomics and metabolomics.

Year:  2003        PMID: 14588002     DOI: 10.1021/ac0346858

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  8 in total

1.  Characteristics of stability boundary and frequency in nonlinear ion trap mass spectrometer.

Authors:  Xiaoyu Zhou; Zhiqiang Zhu; Caiqiao Xiong; Rui Chen; Wenjun Xu; Haoxue Qiao; Wen-Ping Peng; Zongxiu Nie; Yi Chen
Journal:  J Am Soc Mass Spectrom       Date:  2010-04-24       Impact factor: 3.109

Review 2.  Miniature and Fieldable Mass Spectrometers: Recent Advances.

Authors:  Dalton T Snyder; Christopher J Pulliam; Zheng Ouyang; R Graham Cooks
Journal:  Anal Chem       Date:  2015-10-21       Impact factor: 6.986

3.  Co-occurrence of boundary and resonance ejection in a multiplexed rectilinear ion trap mass spectrometer.

Authors:  Amy M Tabert; Michael P Goodwin; R Graham Cooks
Journal:  J Am Soc Mass Spectrom       Date:  2005-12-15       Impact factor: 3.109

4.  Novel linear ion trap mass analyzer composed of four planar electrodes.

Authors:  Yishu Song; Guangxiang Wu; Qingyu Song; R Graham Cooks; Zheng Ouyang; Wolfgang R Plass
Journal:  J Am Soc Mass Spectrom       Date:  2006-02-28       Impact factor: 3.109

5.  Simulations of ion trapping in a micrometer-sized cylindrical ion trap.

Authors:  Daniel E Austin; Dolores Cruz; Matthew G Blain
Journal:  J Am Soc Mass Spectrom       Date:  2006-01-25       Impact factor: 3.109

6.  Multiple mass analysis using an ion trap array (ITA) mass analyzer.

Authors:  Xiao Yu; Yanqiu Chu; Xing Ling; Zhengzhi Ding; Chongsheng Xu; Li Ding; Chuan-Fan Ding
Journal:  J Am Soc Mass Spectrom       Date:  2013-09       Impact factor: 3.109

7.  Experimental Observation of the Effects of Translational and Rotational Electrode Misalignment on a Planar Linear Ion Trap Mass Spectrometer.

Authors:  Yuan Tian; Trevor K Decker; Joshua S McClellan; Qinghao Wu; Abraham De la Cruz; Aaron R Hawkins; Daniel E Austin
Journal:  J Am Soc Mass Spectrom       Date:  2018-04-05       Impact factor: 3.109

Review 8.  Towards Higher Sensitivity of Mass Spectrometry: A Perspective From the Mass Analyzers.

Authors:  Chang Li; Shiying Chu; Siyuan Tan; Xinchi Yin; You Jiang; Xinhua Dai; Xiaoyun Gong; Xiang Fang; Di Tian
Journal:  Front Chem       Date:  2021-12-21       Impact factor: 5.221

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.