Literature DB >> 15307768

Rectilinear ion trap: concepts, calculations, and analytical performance of a new mass analyzer.

Zheng Ouyang1, Guangxiang Wu, Yishu Song, Hongyan Li, Wolfgang R Plass, R Graham Cooks.   

Abstract

A mass analyzer based on a rectilinear geometry ion trap (RIT) has been built, and its performance has been characterized. Design concepts for this type of ion trap are delineated with emphasis on the effects of electrode geometry on the calculated electric field. The Mathieu stability region was mapped experimentally. The instrument can be operated using mass-selective instability scans in both the boundary and resonance ejection versions. Comparisons of performance between different versions of the device having different dimensions allowed selection of an optimized geometry with an appropriate distribution of higher-order electric fields. Comparisons made under the same conditions between the performance of a conventional cylindrical ion trap and a RIT of 4 times greater volume show an improvement of 40 times in the signal-to-noise ratio resulting from the higher ion trapping capacity of the RIT. The demonstrated capabilities of the RIT include tandem mass spectrometry, a mass resolution in excess of 1000, and a mass/charge range of 650 Th, all in a simple structure that is only 3.5 cm(3) in internal volume.

Mesh:

Year:  2004        PMID: 15307768     DOI: 10.1021/ac049420n

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  52 in total

1.  Miniaturization of Mass Spectrometry Analysis Systems.

Authors:  Wei Xu; Nicholas E Manicke; Graham R Cooks; Zheng Ouyang
Journal:  JALA Charlottesv Va       Date:  2010-12

Review 2.  Miniature and Fieldable Mass Spectrometers: Recent Advances.

Authors:  Dalton T Snyder; Christopher J Pulliam; Zheng Ouyang; R Graham Cooks
Journal:  Anal Chem       Date:  2015-10-21       Impact factor: 6.986

3.  Theoretical Study of Dual-Direction Dipolar Excitation of Ions in Linear Ion Traps.

Authors:  Qiankun Dang; Fuxing Xu; Liang Wang; Xiaohua Huang; Xinhua Dai; Xiang Fang; Rizhi Wang; Chuan-Fan Ding
Journal:  J Am Soc Mass Spectrom       Date:  2016-01-26       Impact factor: 3.109

4.  Co-occurrence of boundary and resonance ejection in a multiplexed rectilinear ion trap mass spectrometer.

Authors:  Amy M Tabert; Michael P Goodwin; R Graham Cooks
Journal:  J Am Soc Mass Spectrom       Date:  2005-12-15       Impact factor: 3.109

5.  Novel linear ion trap mass analyzer composed of four planar electrodes.

Authors:  Yishu Song; Guangxiang Wu; Qingyu Song; R Graham Cooks; Zheng Ouyang; Wolfgang R Plass
Journal:  J Am Soc Mass Spectrom       Date:  2006-02-28       Impact factor: 3.109

6.  Ion trajectory simulation for electrode configurations with arbitrary geometries.

Authors:  Guangxiang Wu; R Graham Cooks; Zheng Ouyang; Meng Yu; William J Chappell; Wolfgang R Plass
Journal:  J Am Soc Mass Spectrom       Date:  2006-06-21       Impact factor: 3.109

7.  Miniature toroidal radio frequency ion trap mass analyzer.

Authors:  Stephen A Lammert; Alan A Rockwood; Miao Wang; Milton L Lee; Edgar D Lee; Samuel E Tolley; James R Oliphant; Jeffrey L Jones; Randall W Waite
Journal:  J Am Soc Mass Spectrom       Date:  2006-05-12       Impact factor: 3.109

8.  A Miniaturized Linear Wire Ion Trap with Electron Ionization and Single Photon Ionization Sources.

Authors:  Qinghao Wu; Yuan Tian; Ailin Li; Derek Andrews; Aaron R Hawkins; Daniel E Austin
Journal:  J Am Soc Mass Spectrom       Date:  2017-01-31       Impact factor: 3.109

9.  A novel high-capacity ion trap-quadrupole tandem mass spectrometer.

Authors:  Andrew N Krutchinsky; Herbert Cohen; Brian T Chait
Journal:  Int J Mass Spectrom       Date:  2007       Impact factor: 1.986

10.  High efficiency tandem mass spectrometry analysis using dual linear ion traps.

Authors:  Linfan Li; Xiaoyu Zhou; James W Hager; Zheng Ouyang
Journal:  Analyst       Date:  2014-10-07       Impact factor: 4.616

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.