Literature DB >> 16456650

Estimation of radiation exposure in low-dose multislice computed tomography of the heart and comparison with a calculation program.

C Hohl1, G Mühlenbruch, J E Wildberger, C Leidecker, C Süss, T Schmidt, R W Günther, A H Mahnken.   

Abstract

The purpose of this study was to evaluate the achievable organ dose savings in low-dose multislice computed tomography (MSCT) of the heart using different tube voltages (80 kVp, 100 kVp, 120 kVp) and compare it with calculated values. A female Alderson-Rando phantom was equipped with thermoluminescent dosimeters (TLDs) in five different positions to assess the mean doses within representative organs (thyroid gland, thymus, oesophagus, pancreas, liver). Radiation exposure was performed on a 16-row MSCT scanner with six different routine scan protocols: a 120-kV and a 100-kV CT angiography (CTA) protocol with the same collimation, two 120-kV Ca-scoring (CS) protocols with different collimations and two 80-kV CS protocols with the same collimation as the 120-kV CS protocols. Each scan protocol was repeated five times. The measured dose values for the organs were compared with the values calculated by a commercially available computer program. Directly irradiated organs, such as the esophagus, received doses of 34.7 mSv (CTA 16x0.75 120 kVp), 21.9 mSv (CTA 16x0.75 100 kVp) and 4.96 mSv (CS score 12x1.5 80 kVp), the thyroid as an organ receiving only scattered radiation collected organ doses of 2.98 mSv (CTA 16x0.75 120 kVp), 1.97 mSv (CTA 16x0.75 100 kVp) and 0.58 mSv (CS score 12x1.5 80 kVp). The measured relative organ dose reductions from standard to low-kV protocols ranged from 30.9% to 55.9% and were statistically significant (P<0.05). The comparison with the calculated organ doses showed that the calculation program can predict the relative dose reduction of cardiac low photon-energy protocols precisely.

Entities:  

Mesh:

Year:  2006        PMID: 16456650     DOI: 10.1007/s00330-005-0124-y

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  19 in total

1.  [Assessment of the effective dose for routine protocols in conventional CT, electron beam CT and coronary angiography].

Authors:  C Becker; M Schätzl; H Feist; A Bäuml; U J Schöpf; G Michalski; U Lechel; M Hengge; R Brüning; M Reiser
Journal:  Rofo       Date:  1999-01

2.  Technique factors and image quality as functions of patient weight at abdominal CT.

Authors:  W Huda; E M Scalzetti; G Levin
Journal:  Radiology       Date:  2000-11       Impact factor: 11.105

3.  Radiation exposure in multi-slice CT of the heart.

Authors:  M Cohnen; L Poll; C Püttmann; K Ewen; U Mödder
Journal:  Rofo       Date:  2001-04

Review 4.  Performance evaluation of a 64-slice CT system with z-flying focal spot.

Authors:  T Flohr; K Stierstorfer; R Raupach; S Ulzheimer; H Bruder
Journal:  Rofo       Date:  2004-12

5.  Radiation dose reduction to the male gonads during MDCT: the effectiveness of a lead shield.

Authors:  Christian Hohl; Andreas H Mahnken; Ernst Klotz; Marco Das; Achim Stargardt; Georg Mühlenbruch; Thorsten Schmidt; Rolf W Günther; Joachim E Wildberger
Journal:  AJR Am J Roentgenol       Date:  2005-01       Impact factor: 3.959

6.  Individually adapted examination protocols for reduction of radiation exposure in chest CT.

Authors:  J E Wildberger; A H Mahnken; T Schmitz-Rode; T Flohr; A Stargardt; P Haage; S Schaller; R W Günther
Journal:  Invest Radiol       Date:  2001-10       Impact factor: 6.016

7.  Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography.

Authors:  Koen Nieman; Filippo Cademartiri; Pedro A Lemos; Rolf Raaijmakers; Peter M T Pattynama; Pim J de Feyter
Journal:  Circulation       Date:  2002-10-15       Impact factor: 29.690

8.  Detection of coronary calcifications: feasibility of dose reduction with a body weight-adapted examination protocol.

Authors:  A H Mahnken; J E Wildberger; J Simon; R Koos; T G Flohr; S Schaller; R W Günther
Journal:  AJR Am J Roentgenol       Date:  2003-08       Impact factor: 3.959

9.  Cardiac imaging with a high-speed Cine-CT Scanner: preliminary results.

Authors:  M J Lipton; C B Higgins; D Farmer; D P Boyd
Journal:  Radiology       Date:  1984-09       Impact factor: 11.105

10.  Ultra-low-dose coronary artery calcium screening using multislice CT with retrospective ECG gating.

Authors:  Tobias F Jakobs; Bernd J Wintersperger; Peter Herzog; Thomas Flohr; Christoph Suess; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2003-05-21       Impact factor: 5.315

View more
  14 in total

Review 1.  CT angiography in the diagnosis of cardiovascular disease: a transformation in cardiovascular CT practice.

Authors:  Zhonghua Sun; Mansour Al Moudi; Yan Cao
Journal:  Quant Imaging Med Surg       Date:  2014-10

2.  Absorbed radiation dose in radiosensitive organs during coronary CT angiography using 320-MDCT: effect of maximum tube voltage and heart rate variations.

Authors:  Boris Nikolic; Faisal Khosa; Pei-Jan Paul Lin; Atif N Khan; Sheryar Sarwar; Chun-Shan Yam; Laurence E Court; Vassilios Raptopoulos; Melvin E Clouse
Journal:  AJR Am J Roentgenol       Date:  2010-12       Impact factor: 3.959

3.  Evaluation of dose exposure in 64-slice CT colonography.

Authors:  O Luz; M Buchgeister; M Klabunde; T Trabold; A F Kopp; C D Claussen; M Heuschmid
Journal:  Eur Radiol       Date:  2007-02-07       Impact factor: 5.315

Review 4.  Coronary CT angiography: Dose reduction strategies.

Authors:  Akmal Sabarudin; Zhonghua Sun
Journal:  World J Cardiol       Date:  2013-12-26

5.  Non-invasive evaluation of coronary artery stent patency with retrospectively ECG-gated 64-slice CT angiography.

Authors:  Iacopo Carbone; Marco Francone; Emanuela Algeri; Antonino Granatelli; Alessandro Napoli; Miles A Kirchin; Carlo Catalano; Roberto Passariello
Journal:  Eur Radiol       Date:  2007-10-10       Impact factor: 5.315

6.  Thyroid dose from common head and neck CT examinations in children: is there an excess risk for thyroid cancer induction?

Authors:  Michalis Mazonakis; Antonis Tzedakis; John Damilakis; Nicholas Gourtsoyiannis
Journal:  Eur Radiol       Date:  2006-09-21       Impact factor: 5.315

7.  Diagnostic value of ECG-gated multidetector computed tomography in the early phase of suspected acute myocarditis. A preliminary comparative study with cardiac MRI.

Authors:  Grégoire Dambrin; Jean Pierre Laissy; Jean Michel Serfaty; Christophe Caussin; Bernard Lancelin; Jean François Paul
Journal:  Eur Radiol       Date:  2006-09-05       Impact factor: 5.315

8.  Evaluation of automated attenuation-based tube current adaptation for coronary calcium scoring in MDCT in a cohort of 262 patients.

Authors:  Georg Mühlenbruch; Christian Hohl; Marco Das; Joachim E Wildberger; Christoph Suess; Ernst Klotz; Thomas Flohr; Ralf Koos; Christoph Thomas; Rolf W Günther; Andreas H Mahnken
Journal:  Eur Radiol       Date:  2007-02-17       Impact factor: 5.315

9.  Comprehensive evaluation of preoperative patients with aortic valve stenosis: usefulness of cardiac multidetector computed tomography.

Authors:  Jean-Pierre Laissy; David Messika-Zeitoun; Jean-Michel Serfaty; Vincent Sebban; Elisabeth Schouman-Claeys; Bernard Iung; Alec Vahanian
Journal:  Heart       Date:  2007-05-04       Impact factor: 5.994

10.  Multidetector CT urography: experimental analysis of radiation dose reduction in an animal model.

Authors:  Joern Kemper; Marc Regier; Paul M Bansmann; Philipp G C Begemann; Alexander Stork; Hans Dieter Nagel; Gerhard Adam; Claus Nolte-Ernsting
Journal:  Eur Radiol       Date:  2007-02-14       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.