Literature DB >> 16422410

High-frequency dynamics of ultrasound contrast agents.

Yang Sun1, Dustin E Kruse, Paul A Dayton, Katherine W Ferrara.   

Abstract

Ultrasound contrast agents enhance echoes from the microvasculature and enable the visualization of flow in smaller vessels. Here, we optically and acoustically investigate microbubble oscillation and echoes following insonation with a 10 MHz center frequency pulse. A high-speed camera system with a temporal resolution of 10 ns, which provides two-dimensional (2-D) frame images and streak images, is used in optical experiments. Two confocally aligned transducers, transmitting at 10 MHz and receiving at 5 MHz, are used in acoustical experiments in order to detect subharmonic components. Results of a numerical evaluation of the modified Rayleigh-Plesset equation are used to predict the dynamics of a microbubble and are compared to results of in vitro experiments. From the optical observations of a single microbubble, nonlinear oscillation, destruction, and radiation force are observed. The maximum bubble expansion, resulting from insonation with a 20-cycle, 10-MHz linear chirp with a peak negative pressure of 3.5 MPa, has been evaluated. For an initial diameter ranging from 1.5 to 5 microm, a maximum diameter less than 8 microm is produced during insonation. Optical and acoustical experiments provide insight into the mechanisms of destruction, including fragmentation and active diffusion. High-frequency pulse transmission may provide the opportunity to detect contrast echoes resulting from a single pulse, may be robust in the presence of tissue motion, and may provide the opportunity to incorporate high-frequency ultrasound into destruction-replenishment techniques.

Mesh:

Substances:

Year:  2005        PMID: 16422410      PMCID: PMC1420637          DOI: 10.1109/tuffc.2005.1561667

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  28 in total

1.  Optical imaging of contrast agent microbubbles in an ultrasound field with a 100-MHz camera.

Authors:  N de Jong; P J Frinking; A Bouakaz; M Goorden; T Schourmans; X Jingping; F Mastik
Journal:  Ultrasound Med Biol       Date:  2000-03       Impact factor: 2.998

Review 2.  Ultrasonic contrast agents: safety considerations reviewed.

Authors:  G R ter Haar
Journal:  Eur J Radiol       Date:  2002-03       Impact factor: 3.528

3.  Mechanisms of contrast agent destruction.

Authors:  J E Chomas; P Dayton; J Allen; K Morgan; K W Ferrara
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2001-01       Impact factor: 2.725

4.  Pressure dependence of subharmonic signals from contrast microbubbles.

Authors:  W T Shi; F Forsberg; J S Raichlen; L Needleman; B B Goldberg
Journal:  Ultrasound Med Biol       Date:  1999-02       Impact factor: 2.998

5.  A new high resolution color flow system using an eigendecomposition-based adaptive filter for clutter rejection.

Authors:  Dustin E Kruse; Katherine W Ferrara
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2002-12       Impact factor: 2.725

6.  Nondestructive subharmonic imaging.

Authors:  James Chomas; Paul Dayton; Donovan May; Katherine Ferrara
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2002-07       Impact factor: 2.725

7.  A swept-scanning mode for estimation of blood velocity in the microvasculature.

Authors:  D E Kruse; R H Silverman; R J Fornaris; D J Coleman; K W Ferrara
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1998       Impact factor: 2.725

8.  Optical and acoustical observations of the effects of ultrasound on contrast agents.

Authors:  P A Dayton; K E Morgan; A L Klibanov; G H Brandenburger; K W Ferrara
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1999       Impact factor: 2.725

9.  A wall-less vessel phantom for Doppler ultrasound studies.

Authors:  D W Rickey; P A Picot; D A Christopher; A Fenster
Journal:  Ultrasound Med Biol       Date:  1995       Impact factor: 2.998

10.  High-frequency 3-D color-flow imaging of the microcirculation.

Authors:  David E Goertz; Joanne L Yu; Robert S Kerbel; Peter N Burns; F Stuart Foster
Journal:  Ultrasound Med Biol       Date:  2003-01       Impact factor: 2.998

View more
  17 in total

1.  In vivo transcranial cavitation threshold detection during ultrasound-induced blood-brain barrier opening in mice.

Authors:  Yao-Sheng Tung; Fotios Vlachos; James J Choi; Thomas Deffieux; Kirsten Selert; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2010-09-29       Impact factor: 3.609

2.  Shell properties and concentration stability of acoustofluidic delivery agents.

Authors:  Hussain Alsadiq; Karnaker Tupally; Robert Vogel; Ganesh Kokil; Harendra S Parekh; Martin Veidt
Journal:  Phys Eng Sci Med       Date:  2021-01-04

3.  The response of phospholipid-encapsulated microbubbles to chirp-coded excitation: implications for high-frequency nonlinear imaging.

Authors:  Himanshu Shekhar; Marvin M Doyley
Journal:  J Acoust Soc Am       Date:  2013-05       Impact factor: 1.840

4.  Algal cell disruption using microbubbles to localize ultrasonic energy.

Authors:  Joel D Krehbiel; Lance C Schideman; Daniel A King; Jonathan B Freund
Journal:  Bioresour Technol       Date:  2014-09-22       Impact factor: 9.642

5.  Contrast-enhanced ultrasound imaging using pulse inversion spectral deconvolution.

Authors:  Mawia Khairalseed; Ipek Oezdemir; Kenneth Hoyt
Journal:  J Acoust Soc Am       Date:  2019-10       Impact factor: 1.840

6.  Real-time texture analysis for identifying optimum microbubble concentration in 2-D ultrasonic particle image velocimetry.

Authors:  Lili Niu; Ming Qian; Liang Yan; Wentao Yu; Bo Jiang; Qiaofeng Jin; Yanping Wang; Robin Shandas; Xin Liu; Hairong Zheng
Journal:  Ultrasound Med Biol       Date:  2011-06-17       Impact factor: 2.998

7.  Prolonging pulse duration in ultrasound-mediated gene delivery lowers acoustic pressure threshold for efficient gene transfer to cells and small animals.

Authors:  Dominic M Tran; James Harrang; Shuxian Song; Jeremy Chen; Bryn M Smith; Carol H Miao
Journal:  J Control Release       Date:  2018-04-24       Impact factor: 9.776

8.  Encapsulated microbubbles and echogenic liposomes for contrast ultrasound imaging and targeted drug delivery.

Authors:  Shirshendu Paul; Rahul Nahire; Sanku Mallik; Kausik Sarkar
Journal:  Comput Mech       Date:  2014-03       Impact factor: 4.014

Review 9.  Towards controlled drug delivery in brain tumors with microbubble-enhanced focused ultrasound.

Authors:  Scott Schoen; M Sait Kilinc; Hohyun Lee; Yutong Guo; F Levent Degertekin; Graeme F Woodworth; Costas Arvanitis
Journal:  Adv Drug Deliv Rev       Date:  2021-11-18       Impact factor: 15.470

10.  Resonance frequencies of lipid-shelled microbubbles in the regime of nonlinear oscillations.

Authors:  Alexander A Doinikov; Jillian F Haac; Paul A Dayton
Journal:  Ultrasonics       Date:  2008-09-30       Impact factor: 2.890

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.