Literature DB >> 16381704

Patient neutron dose equivalent exposures outside of the proton therapy treatment field.

J C Polf1, W D Newhauser, U Titt.   

Abstract

A large fraction of dose to healthy tissue located outside of the treatment field during proton therapy is attributable to neutrons produced in the beam-delivery apparatus. In this work, the neutron dose equivalent (H) per therapeutic proton absorbed dose (D) was estimated for typical treatment conditions as a function of range modulation width, angle with respect to the incident proton beam, and the distance from the isocentre at the Harvard Cyclotron Laboratory's (Cambridge, MA) passively spread treatment field using Monte Carlo simulations. For a beam with 16 cm penetration (depth) and a 5 x 5 cm2 lateral field size at the patient location along the incident beam direction at 100 cm from the isocentre, the predicted H/D values are 0.35 and 0.60 mSv Gy(-1) from the simulations and measurements, respectively. At all locations, the predicted H/D values are within a factor of 2 and 3 of the measured result for no modulation and 8.2 cm of modulation, respectively.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16381704     DOI: 10.1093/rpd/nci264

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  15 in total

1.  Microdosimetric measurements in the secondary radiation field produced in (12)C-therapy irradiations.

Authors:  F Wissmann; U Giesen; T Klages; D Schardt; G Martino; C Sunil
Journal:  Radiat Environ Biophys       Date:  2010-03-26       Impact factor: 1.925

2.  An MCNPX Monte Carlo model of a discrete spot scanning proton beam therapy nozzle.

Authors:  Gabriel O Sawakuchi; Dragan Mirkovic; Luis A Perles; Narayan Sahoo; X Ron Zhu; George Ciangaru; Kazumichi Suzuki; Michael T Gillin; Radhe Mohan; Uwe Titt
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

3.  Evaluation of energy deposition and secondary particle production in proton therapy of brain using a slab head phantom.

Authors:  Sayyed Bijan Jia; Mohammad Hadi Hadizadeh; Ali Asghar Mowlavi; Mahdy Ebrahimi Loushab
Journal:  Rep Pract Oncol Radiother       Date:  2014-05-01

4.  Benchmark measurements and simulations of dose perturbations due to metallic spheres in proton beams.

Authors:  Wayne D Newhauser; Laura Rechner; Dragan Mirkovic; Pablo Yepes; Nicholas C Koch; Uwe Titt; Jonas D Fontenot; Rui Zhang
Journal:  Radiat Meas       Date:  2013-11-01       Impact factor: 1.898

5.  Effective Dose from Stray Radiation for a Patient Receiving Proton Therapy for Liver Cancer.

Authors:  Phillip J Taddei; Sunil Krishnan; Dragan Mirkovic; Pablo Yepes; Wayne D Newhauser
Journal:  AIP Conf Proc       Date:  2009-03-10

Review 6.  The physics of proton therapy.

Authors:  Wayne D Newhauser; Rui Zhang
Journal:  Phys Med Biol       Date:  2015-03-24       Impact factor: 3.609

7.  Assessment of the accuracy of an MCNPX-based Monte Carlo simulation model for predicting three-dimensional absorbed dose distributions.

Authors:  U Titt; N Sahoo; X Ding; Y Zheng; W D Newhauser; X R Zhu; J C Polf; M T Gillin; R Mohan
Journal:  Phys Med Biol       Date:  2008-07-31       Impact factor: 3.609

8.  Monte Carlo simulation of the neutron spectral fluence and dose equivalent for use in shielding a proton therapy vault.

Authors:  Yuanshui Zheng; Wayne Newhauser; Eric Klein; Daniel Low
Journal:  Phys Med Biol       Date:  2009-11-04       Impact factor: 3.609

9.  Reducing stray radiation dose to patients receiving passively scattered proton radiotherapy for prostate cancer.

Authors:  Phillip J Taddei; Jonas D Fontenot; Yuanshui Zheng; Dragan Mirkovic; Andrew K Lee; Uwe Titt; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2008-03-27       Impact factor: 3.609

10.  The risk of developing a second cancer after receiving craniospinal proton irradiation.

Authors:  Wayne D Newhauser; Jonas D Fontenot; Anita Mahajan; David Kornguth; Marilyn Stovall; Yuanshui Zheng; Phillip J Taddei; Dragan Mirkovic; Radhe Mohan; James D Cox; Shiao Woo
Journal:  Phys Med Biol       Date:  2009-03-20       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.