Literature DB >> 16331042

Comparison of corneal thickness after the instillation of topical anesthetics: proparacaine versus oxybuprocaine.

Sang Min Nam1, Hyung Keun Lee, Eung Kweon Kim, Kyoung Yul Seo.   

Abstract

PURPOSE: To compare changes in human corneal thickness after the instillation of proparacaine with those after oxybuprocaine instillation with time over a period of 10 minutes.
METHODS: Eighteen healthy young participants were recruited. Proparacaine was used in the right eye and oxybuprocaine in the left. Right and left baseline corneal thicknesses were measured every 30 seconds for 10 minutes using a noncontact specular microscope by 1 observer. Baseline corneal thickness was defined as the average of all values taken over 10 minutes. Changes in corneal thickness were measured every 20 seconds for 10 minutes after the administration of 1 drop of 0.5% proparacaine onto the right cornea and 1 drop of 0.4% oxybuprocaine onto the left cornea.
RESULTS: Mean baseline right cornea thickness was 531 +/- 45 microm, and that of the left cornea was 531 +/- 42 microm. The corneal thickness after proparacaine increased by 8.6 microm ( approximately 4.5-12.6 microm, 95% CI) and then returned to baseline within 80 seconds. Corneal thickness after applying oxybuprocaine increased by 7.7 microm (3.6-11.2 microm, 95% CI) and then returned to baseline within 80 seconds. There was a second transient increase about 5 minutes later after proparacaine instillation but no additional transient increase after oxybuprocaine instillation.
CONCLUSION: Oxybuprocaine is similar to proparacaine in terms of the severity of its effect on corneal thickness. Corneal thickness instability may occur for 5 minutes after proparacaine administration. Changes in corneal thickness after topical anesthetic instillation should be considered when performing measurements for refractive surgery or central corneal thickness in glaucoma patients.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16331042     DOI: 10.1097/01.ico.0000179929.97651.59

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  20 in total

1.  Comparison of central corneal thickness using anterior segment optical coherence tomography vs ultrasound pachymetry.

Authors:  Hanna Y Kim; Donald L Budenz; Pak S Lee; William J Feuer; Keith Barton
Journal:  Am J Ophthalmol       Date:  2007-12-11       Impact factor: 5.258

2.  Comparison between central corneal thickness measurements by oculus pentacam and ultrasonic pachymetry.

Authors:  Hani S Al-Mezaine; Saleh A Al-Amro; Dustan Kangave; Abdulkareem Sadaawy; Taher A Wehaib; Saleh Al-Obeidan
Journal:  Int Ophthalmol       Date:  2007-09-26       Impact factor: 2.031

3.  Letter to the editor. "Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery".

Authors:  Alberto López-Miguel; María Sanchidrián; Itziar Fernández; Alfredo Holgueras; Miguel J Maldonado
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-02-11       Impact factor: 3.117

4.  Comparison of central corneal thickness measurements with three new optical devices and a standard ultrasonic pachymeter.

Authors:  Hasan Ali Bayhan; Seray Aslan Bayhan; Izzet Can
Journal:  Int J Ophthalmol       Date:  2014-04-18       Impact factor: 1.779

5.  Long-acting liposomal corneal anesthetics.

Authors:  Changyou Zhan; Claudia M Santamaria; Weiping Wang; J Brian McAlvin; Daniel S Kohane
Journal:  Biomaterials       Date:  2018-08-09       Impact factor: 12.479

6.  Comparison of Central Corneal Thickness using Anterior Segment Optical Coherence Tomography Versus Ultrasound Pachymetry.

Authors:  Prasanna Venkatesh Ramesh; Kirti Nath Jha; Krishnagopal Srikanth
Journal:  J Clin Diagn Res       Date:  2017-08-01

7.  Comparative evaluation of TonoPen AVIA, Goldmann applanation tonometry and non-contact tonometry.

Authors:  Shibal Bhartiya; Shveta Jindal Bali; Reetika Sharma; Neha Chaturvedi; Tanuj Dada
Journal:  Int Ophthalmol       Date:  2011-07-15       Impact factor: 2.031

8.  Evaluation of rebound tonometry in non-human primates.

Authors:  Elizabeth J Elsmo; Julie A Kiland; Paul L Kaufman; Gillian J McLellan
Journal:  Exp Eye Res       Date:  2011-02-16       Impact factor: 3.467

9.  The effect of topical anesthesia on the rat electroretinogram.

Authors:  Shai Sandalon; Ron Ofri
Journal:  Doc Ophthalmol       Date:  2008-07-30       Impact factor: 2.379

10.  Clinical investigation of the effect of topical anesthesia on intraocular pressure.

Authors:  Turki M Almubrad; Kelechi C Ogbuehi
Journal:  Clin Ophthalmol       Date:  2007-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.