Literature DB >> 16315207

Undersampled elliptical centric view-order for improved spatial resolution in contrast-enhanced MR angiography.

Ananth J Madhuranthakam1, Houchun H Hu, Andrew V Barger, Clifton R Haider, David G Kruger, James F Glockner, John Huston, Stephen J Riederer.   

Abstract

Although contrast-enhanced MR angiography (CE-MRA) has been successfully developed into a routine clinical imaging technique, there is still need for improved spatial resolution in a given acquisition time. Undersampled projection reconstruction (PR) techniques maintain spatial resolution with reduced scan times, and the elliptical centric (EC) view order provides high quality arterial phase images without venous contamination. In this work, we present a hybrid elliptical centric-projection reconstruction (EC-PR) technique to provide spatial resolution improvement over standard EC in a given time. The k-space sampling was performed by undersampling the periphery of the k(Y)-k(Z) phase encoding plane of an EC view order in a PR like manner. The sampled views were maintained on a rectilinear grid, and thus reconstructed by standard 3DFT. The non-sampled views were compensated either by zero-filling or performing a 2D homodyne reconstruction. Compared to a fully sampled k-space, the EC-PR sequence acquired in the same scan time provides a resolution improvement of about two, as shown by point spread function analysis and phantom experiments. The hypothesis that EC-PR provides improved resolution while retaining diagnostically adequate SNR was tested in 11 CE-MRA studies of the popliteal and carotid arteries and shown to be true (P < 0.03).

Mesh:

Substances:

Year:  2006        PMID: 16315207     DOI: 10.1002/mrm.20726

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  15 in total

1.  Combination of 2D sensitivity encoding and 2D partial fourier techniques for improved acceleration in 3D contrast-enhanced MR angiography.

Authors:  Houchun H Hu; Ananth J Madhuranthakam; David G Kruger; James F Glockner; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2006-01       Impact factor: 4.668

2.  Time-of-arrival mapping at three-dimensional time-resolved contrast-enhanced MR angiography.

Authors:  Stephen J Riederer; Clifton R Haider; Eric A Borisch
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

3.  Recent advances in 3D time-resolved contrast-enhanced MR angiography.

Authors:  Stephen J Riederer; Clifton R Haider; Eric A Borisch; Paul T Weavers; Phillip M Young
Journal:  J Magn Reson Imaging       Date:  2015-06-01       Impact factor: 4.813

4.  Sampling strategies for subsampled segmented EPI PRF thermometry in MR guided high intensity focused ultrasound.

Authors:  Henrik Odéen; Nick Todd; Mahamadou Diakite; Emilee Minalga; Allison Payne; Dennis L Parker
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

5.  Buildup of image quality in view-shared time-resolved 3D CE-MRA.

Authors:  Casey P Johnson; Thomas W Polley; James F Glockner; Phillip M Young; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2012-08-30       Impact factor: 4.668

6.  DIfferential Subsampling with Cartesian Ordering (DISCO): a high spatio-temporal resolution Dixon imaging sequence for multiphasic contrast enhanced abdominal imaging.

Authors:  Manojkumar Saranathan; Dan W Rettmann; Brian A Hargreaves; Sharon E Clarke; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2012-02-14       Impact factor: 4.813

7.  Time-resolved imaging of contrast kinetics three-dimensional (3D) magnetic resonance venography in patients with pelvic congestion syndrome.

Authors:  E A Dick; C Burnett; A Anstee; M Hamady; D Black; W M W Gedroyc
Journal:  Br J Radiol       Date:  2010-10       Impact factor: 3.039

8.  3D sensitivity encoded ellipsoidal MR spectroscopic imaging of gliomas at 3T.

Authors:  Esin Ozturk-Isik; Albert P Chen; Jason C Crane; Wei Bian; Duan Xu; Eric T Han; Susan M Chang; Daniel B Vigneron; Sarah J Nelson
Journal:  Magn Reson Imaging       Date:  2009-09-19       Impact factor: 2.546

9.  3D Cartesian MRI with compressed sensing and variable view sharing using complementary poisson-disc sampling.

Authors:  Evan Levine; Bruce Daniel; Shreyas Vasanawala; Brian Hargreaves; Manojkumar Saranathan
Journal:  Magn Reson Med       Date:  2016-04-21       Impact factor: 4.668

10.  Controlled experimental study depicting moving objects in view-shared time-resolved 3D MRA.

Authors:  Petrice M Mostardi; Clifton R Haider; Phillip J Rossman; Eric A Borisch; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.