Literature DB >> 16310109

Magnetic resonance cholangiopancreatography using a free-breathing T2-weighted turbo spin-echo sequence with navigator-triggered prospective acquisition correction.

Patrick Asbach1, Christian Klessen, Thomas J Kroencke, Claudia Kluner, Alto Stemmer, Bernd Hamm, Matthias Taupitz.   

Abstract

PURPOSE: The objective of this study was to evaluate the image quality of a respiratory-triggered T2-weighted (T2w) turbo spin-echo (TSE) sequence for magnetic resonance cholangiopancreatography (MRCP) using a new method for respiratory triggering by tracking the motion of the right diaphragm [prospective acquisition correction (PACE) technique].
MATERIALS AND METHODS: Fifty consecutive patients underwent MRCP imaging applying breath-hold half-Fourier single-shot TSE sequences and the respiratory-triggered T2w TSE sequence. Qualitative evaluation grading the depiction of eight segments of the pancreaticobiliary tree and the frequency of artifacts was performed. Quantitative evaluation included calculation of the relative contrast (RC) between fluid-filled ductal structures and organ parenchyma at four segments.
RESULTS: A significantly higher (P<.01) RC was measured for the respiratory-triggered T2w TSE sequence [maximum intensity projection (MIP)] for all of the four investigated segments (one of four segments for the MIP) of the pancreaticobiliary tree, as well as a significant (P<.01) improvement of visualization of all ductal segments compared with the breath-hold sequences. The frequency of artifacts was significantly lower (P<.01) compared with the breath-hold sequences.
CONCLUSION: Respiratory-triggered MRCP using a T2w TSE sequence with PACE significantly improves image quality and may be included into the routine MRCP sequence protocol.

Entities:  

Mesh:

Year:  2005        PMID: 16310109     DOI: 10.1016/j.mri.2005.07.002

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  8 in total

1.  Utility of navigator-prospective acquisition correction technique (PACE) for reducing motion in brain MR imaging studies.

Authors:  J D Barnwell; J K Smith; M Castillo
Journal:  AJNR Am J Neuroradiol       Date:  2007-04       Impact factor: 3.825

2.  Improved renal perfusion measurement with a dual navigator-gated Q2TIPS fair technique.

Authors:  Ruitian Song; Ralf B Loeffler; Claudia M Hillenbrand
Journal:  Magn Reson Med       Date:  2010-11       Impact factor: 4.668

3.  Magnetic resonance cholangiopancreatography with GRASE sequence at 3.0T: does it improve image quality and acquisition time as compared with 3D TSE?

Authors:  Morikatsu Yoshida; Takeshi Nakaura; Taihei Inoue; Shota Tanoue; Sentaro Takada; Daisuke Utsunomiya; Shota Tsumagari; Kazunori Harada; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2018-01-15       Impact factor: 5.315

4.  Breath-held MR cholangiopancreatography (MRCP) using a 3D Dixon fat-water separated balanced steady state free precession sequence.

Authors:  James F Glockner; Manojkumar Saranathan; Ersin Bayram; Christine U Lee
Journal:  Magn Reson Imaging       Date:  2013-07-20       Impact factor: 2.546

5.  Magnetic resonance cholangiography: comparison of two- and three-dimensional sequences for assessment of malignant biliary obstruction.

Authors:  Jin-Young Choi; Myeong-Jin Kim; Jeong Min Lee; Jae Young Lee; Se Hyung Kim; Ki Whang Kim; Joon Koo Han; Byung Ihn Choi
Journal:  Eur Radiol       Date:  2007-05-22       Impact factor: 5.315

6.  Quantification of hepatic iron concentration in chronic viral hepatitis: usefulness of T2-weighted single-shot spin-echo echo-planar MR imaging.

Authors:  Tatsuyuki Tonan; Kiminori Fujimoto; Aliya Qayyum; Takumi Kawaguchi; Atsushi Kawaguchi; Osamu Nakashima; Koji Okuda; Naofumi Hayabuchi; Michio Sata
Journal:  PLoS One       Date:  2012-03-16       Impact factor: 3.240

7.  Rapid high-resolution volumetric T1 mapping using a highly accelerated stack-of-stars Look Locker technique.

Authors:  Zhitao Li; Zhiyang Fu; Mahesh Keerthivasan; Ali Bilgin; Kevin Johnson; Jean-Philippe Galons; Srinivasan Vedantham; Diego R Martin; Maria I Altbach
Journal:  Magn Reson Imaging       Date:  2021-03-17       Impact factor: 3.130

8.  Balanced steady-state free precession MRCP is a robust alternative to respiration-navigated 3D turbo-spin-echo MRCP.

Authors:  Felix Christian Hasse; Buket Selmi; Hamed Albusaidi; Theresa Mokry; Philipp Mayer; Christian Rupp; Hans-Ulrich Kauczor; Tim Frederik Weber
Journal:  BMC Med Imaging       Date:  2021-01-11       Impact factor: 1.930

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.