Literature DB >> 23876262

Breath-held MR cholangiopancreatography (MRCP) using a 3D Dixon fat-water separated balanced steady state free precession sequence.

James F Glockner1, Manojkumar Saranathan, Ersin Bayram, Christine U Lee.   

Abstract

A novel 3D breath-held Dixon fat-water separated balanced steady state free precession (b-SSFP) sequence for MR cholangiopancreatography (MRCP) is described and its potential clinical utility assessed in a series of patients. The main motivation is to develop a robust breath-held alternative to the respiratory gated 3D Fast Spin Echo (FSE) sequence, the current clinical sequence of choice for MRCP. Respiratory gated acquisitions are susceptible to motion artifacts and blurring in patients with significant diaphragmatic drift, erratic respiratory rhythms or sleep apnea. A two point Dixon fat-water separation scheme was developed which eliminates signal loss arising from B0 inhomogeneity effects and minimizes artifacts from perturbation of the b-SSFP steady state. Preliminary results from qualitative analysis of 49 patients demonstrate robust performance of the 3D Dixon b-SSFP sequence with diagnostic image quality acquired in a 20-24s breath-hold.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Biliary; MRCP; steady state free precession

Mesh:

Substances:

Year:  2013        PMID: 23876262      PMCID: PMC4054824          DOI: 10.1016/j.mri.2013.06.008

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  21 in total

1.  Fast spin echo sequences with very long echo trains: design of variable refocusing flip angle schedules and generation of clinical T2 contrast.

Authors:  Reed F Busse; Hari Hariharan; Anthony Vu; Jean H Brittain
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

2.  Three-dimensional fast-recovery fast spin-echo MRCP: comparison with two-dimensional single-shot fast spin-echo techniques.

Authors:  Aaron Sodickson; Koenraad J Mortele; Matthew A Barish; Kelly H Zou; Steven Thibodeau; Clare M C Tempany
Journal:  Radiology       Date:  2006-02       Impact factor: 11.105

3.  Navigator-triggered prospective acquisition correction (PACE) technique vs. conventional respiratory-triggered technique for free-breathing 3D MRCP: an initial prospective comparative study using healthy volunteers.

Authors:  Satoru Morita; Eiko Ueno; Kazufumi Suzuki; Haruhiko Machida; Mikihiko Fujimura; Shinya Kojima; Masami Hirata; Takahiro Ohnishi; Chiaki Imura
Journal:  J Magn Reson Imaging       Date:  2008-09       Impact factor: 4.813

4.  Comparison of different MRCP techniques for the depiction of biliary complications after liver transplantation.

Authors:  Sonja Kinner; Alexander Dechêne; Susanne C Ladd; Thomas Zöpf; Evelin Maldonado de Dechêne; Guido Gerken; Thomas C Lauenstein
Journal:  Eur Radiol       Date:  2010-02-16       Impact factor: 5.315

5.  Usefulness of the navigator-echo triggering technique for free-breathing three-dimensional magnetic resonance cholangiopancreatography.

Authors:  Keiji Matsunaga; Gou Ogasawara; Masaru Tsukano; Yuji Iwadate; Yusuke Inoue
Journal:  Magn Reson Imaging       Date:  2012-10-25       Impact factor: 2.546

6.  Breath-hold projection magnetic resonance-cholangio-pancreaticography (MRCP): a new method for the examination of the bile and pancreatic ducts.

Authors:  J Laubenberger; M Büchert; B Schneider; U Blum; J Hennig; M Langer
Journal:  Magn Reson Med       Date:  1995-01       Impact factor: 4.668

Review 7.  MRCP vs. ERCP in the evaluation of biliary pathologies: review of current literature.

Authors:  Koray Hekimoglu; Yucel Ustundag; Abdurrahim Dusak; Zuhal Erdem; Bulent Karademir; Selim Aydemir; Sadi Gundogdu
Journal:  J Dig Dis       Date:  2008-08       Impact factor: 2.325

8.  Another dimension in magnetic resonance cholangiopancreatography: comparison of 2- and 3-dimensional magnetic resonance cholangiopancreatography for the evaluation of intraductal papillary mucinous neoplasm of the pancreas.

Authors:  Luke S Yoon; Onofrio A Catalano; Stefan Fritz; Cristina R Ferrone; Peter F Hahn; Dushyant V Sahani
Journal:  J Comput Assist Tomogr       Date:  2009 May-Jun       Impact factor: 1.826

9.  N/2 ghosting artifacts: elimination at 3.0-T MR cholangiography with SPACE pulse sequence.

Authors:  Clare M Haystead; Brian M Dale; Elmar M Merkle
Journal:  Radiology       Date:  2008-02       Impact factor: 11.105

10.  Navigator-triggered isotropic three-dimensional magnetic resonance cholangiopancreatography in the diagnosis of malignant biliary obstructions: comparison with direct cholangiography.

Authors:  Jin-Young Choi; Jeong Min Lee; Jae Young Lee; Se Hyung Kim; Min Woo Lee; Joon Koo Han; Byung Ihn Choi
Journal:  J Magn Reson Imaging       Date:  2008-01       Impact factor: 4.813

View more
  7 in total

1.  Coronal 2D MR cholangiography overestimates the length of the right hepatic duct in liver transplantation donors.

Authors:  Bohyun Kim; Kyoung Won Kim; So Yeon Kim; So Hyun Park; Jeongjin Lee; Gi Won Song; Dong-Hwan Jung; Tae-Yong Ha; Sung Gyu Lee
Journal:  Eur Radiol       Date:  2016-09-05       Impact factor: 5.315

2.  Three-dimensional MR Cholangiopancreatography in a Breath Hold with Sparsity-based Reconstruction of Highly Undersampled Data.

Authors:  Hersh Chandarana; Ankur M Doshi; Alampady Shanbhogue; James S Babb; Mary T Bruno; Tiejun Zhao; Esther Raithel; Michael O Zenge; Guobin Li; Ricardo Otazo
Journal:  Radiology       Date:  2016-03-16       Impact factor: 11.105

3.  The diagnostic value of magnetic resonance urography using a balanced turbo field echo sequence.

Authors:  Egemen Çifçi; Gökçen Çoban; Tufan Çiçek; Umut Gönülalan
Journal:  Eur Radiol       Date:  2016-03-16       Impact factor: 5.315

Review 4.  Magnetic resonance urography: a practical approach to preparation, protocol and interpretation.

Authors:  Hansel J Otero; Mohamed M Elsingergy; Susan J Back
Journal:  Pediatr Radiol       Date:  2022-09-23

5.  GRASE Revisited: breath-hold three-dimensional (3D) magnetic resonance cholangiopancreatography using a Gradient and Spin Echo (GRASE) technique at 3T.

Authors:  Ju Gang Nam; Jeong Min Lee; Hyo-Jin Kang; Sang Min Lee; Eunju Kim; Johannes M Peeters; Jeong Hee Yoon
Journal:  Eur Radiol       Date:  2018-02-01       Impact factor: 5.315

6.  Magnetic resonance cholangiopancreatography at 3T in a single breath-hold: comparative effectiveness between three-dimensional (3D) gradient- and spin-echo and two-dimensional (2D) thick-slab fast spin-echo acquisitions.

Authors:  Cheng-Ping Chien; Feng-Mao Chiu; Yen-Chun Shen; Yi-Hsun Chen; Hsiao-Wen Chung
Journal:  Quant Imaging Med Surg       Date:  2020-06

7.  Balanced steady-state free precession MRCP is a robust alternative to respiration-navigated 3D turbo-spin-echo MRCP.

Authors:  Felix Christian Hasse; Buket Selmi; Hamed Albusaidi; Theresa Mokry; Philipp Mayer; Christian Rupp; Hans-Ulrich Kauczor; Tim Frederik Weber
Journal:  BMC Med Imaging       Date:  2021-01-11       Impact factor: 1.930

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.