Literature DB >> 33430780

Balanced steady-state free precession MRCP is a robust alternative to respiration-navigated 3D turbo-spin-echo MRCP.

Felix Christian Hasse1, Buket Selmi2, Hamed Albusaidi2, Theresa Mokry2, Philipp Mayer2, Christian Rupp3, Hans-Ulrich Kauczor2, Tim Frederik Weber2.   

Abstract

BACKGROUND: Despite synchronization to respiration, respiration-navigated (RN) 3D turbo-spin-echo MRCP is limited by susceptibility to motion artifacts. The aim of this study was to assess the quality of pancreaticobiliary duct visualization of a non-RN MRCP alternative based on balanced steady-state free precession imaging (BSSFP) with overlapping slices compared with RN-MRCP.
METHODS: This is a retrospective study on 50 patients without pancreaticobiliary duct disease receiving MRCP at 1.5 T. We performed an intraindividual comparison of coronal RN-MRCP with combined coronal and transverse BSSFP-MRCP. Image quality was scored by 3 readers for 6 pancreaticobiliary duct segments (3 pancreatic, 3 biliary) using a 6-point scale. A segment score of 3 or lower as assessed by at least 2 of 3 readers was defined as insufficient segment visualization. Nonparametric tests and interrater reliability testing were used for statistical analysis.
RESULTS: Overall duct visualization averaged over all readers was scored with 4.5 ± 1.1 for RN-MRCP (pancreatic, 4.1 ± 0.5; biliary, 5.0 ± 0.4) and 4.9 ± 0.9 for combined coronal and transverse BSSFP-MRCP (pancreatic, 4.6 ± 0.6; biliary, 5.1 ± 0.6), respectively (p < 0.001). The number of segments visualized insufficiently was 81/300 for RN-MRCP and 43/300 for BSSFP-MRCP (p < 0.001). Segments visualized insufficiently only in RN-MRCP had a mean score of 4.4 ± 0.8 in BSSFP-MRCP. Overall interrater agreement on superiority of BSSFP-MRCP segment scores over corresponding RN-MRCP was 0.70. Mean acquisition time was 98% longer for RN-MRCP (198.0 ± 98.7 s) than for combined coronal and transverse BSSFP-MRCP (100.2 ± 0.4 s).
CONCLUSIONS: Non-RN BSSFP-MRCP with overlapping slices is a fast alternative to RN-MRCP, frequently providing sufficient duct visualization when RN-MRCP fails.

Entities:  

Keywords:  Biliary tract; Cholangiopancreatography; Magnetic resonance; Pancreas

Mesh:

Year:  2021        PMID: 33430780      PMCID: PMC7802244          DOI: 10.1186/s12880-020-00532-w

Source DB:  PubMed          Journal:  BMC Med Imaging        ISSN: 1471-2342            Impact factor:   1.930


  35 in total

1.  Fluctuating equilibrium MRI.

Authors:  S S Vasanawala; J M Pauly; D G Nishimura
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Magnetic resonance cholangiopancreatography using a free-breathing T2-weighted turbo spin-echo sequence with navigator-triggered prospective acquisition correction.

Authors:  Patrick Asbach; Christian Klessen; Thomas J Kroencke; Claudia Kluner; Alto Stemmer; Bernd Hamm; Matthias Taupitz
Journal:  Magn Reson Imaging       Date:  2005-10-20       Impact factor: 2.546

3.  Dilated biliary tract: evaluation with MR cholangiography with a T2-weighted contrast-enhanced fast sequence.

Authors:  B K Wallner; K A Schumacher; W Weidenmaier; J M Friedrich
Journal:  Radiology       Date:  1991-12       Impact factor: 11.105

4.  Feasibility of 3D navigator-triggered magnetic resonance cholangiopancreatography with combined parallel imaging and compressed sensing reconstruction at 3T.

Authors:  Nieun Seo; Mi-Suk Park; Kyunghwa Han; Dongeun Kim; Kevin F King; Jin-Young Choi; Honsoul Kim; Hye Jin Kim; Minsu Lee; Heejin Bae; Myeong-Jin Kim
Journal:  J Magn Reson Imaging       Date:  2017-03-11       Impact factor: 4.813

5.  Multifrequency reconstruction for frequency-modulated bSSFP.

Authors:  Anne Slawig; Tobias Wech; Valentin Ratz; Johannes Tran-Gia; Henning Neubauer; Thorsten Bley; Herbert Köstler
Journal:  Magn Reson Med       Date:  2017-02-10       Impact factor: 4.668

6.  bSSFP phase correction and its use in magnetic resonance electrical properties tomography.

Authors:  Safa Ozdemir; Yusuf Ziya Ider
Journal:  Magn Reson Med       Date:  2018-10-25       Impact factor: 4.668

7.  The measurement of observer agreement for categorical data.

Authors:  J R Landis; G G Koch
Journal:  Biometrics       Date:  1977-03       Impact factor: 2.571

8.  Navigator-triggered isotropic three-dimensional magnetic resonance cholangiopancreatography in the diagnosis of malignant biliary obstructions: comparison with direct cholangiography.

Authors:  Jin-Young Choi; Jeong Min Lee; Jae Young Lee; Se Hyung Kim; Min Woo Lee; Joon Koo Han; Byung Ihn Choi
Journal:  J Magn Reson Imaging       Date:  2008-01       Impact factor: 4.813

9.  Comparison of different magnetic resonance cholangiography techniques in living liver donors including Gd-EOB-DTPA enhanced T1-weighted sequences.

Authors:  Sonja Kinner; Verena Steinweg; Stefan Maderwald; Arnold Radtke; Georgios Sotiropoulos; Michael Forsting; Tobias Schroeder
Journal:  PLoS One       Date:  2014-11-26       Impact factor: 3.240

10.  Is MRCP necessary to diagnose pancreas divisum?

Authors:  Nino Bogveradze; Felix Hasse; Philipp Mayer; Christian Rupp; Christin Tjaden; Miriam Klauss; Hans-Ulrich Kauczor; Tim Frederik Weber
Journal:  BMC Med Imaging       Date:  2019-04-29       Impact factor: 1.930

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.