Literature DB >> 26257988

CTREC: C-arm Tracking and Reconstruction using Elliptic Curves.

Gouthami Chintalapani1, Ameet K Jain2, David H Burkhardt3, Jerry L Prince1, Gabor Fichtinger4.   

Abstract

C-arm fluoroscopy is ubiquitous in contemporary surgery, but it lacks the ability to accurately reconstruct three-dimensional information, attributable to the difficulty in obtaining the pose of X-ray images in 3D space. We propose a unified mathematical framework to address the issues of intra-operative pose estimation, correspondence and reconstruction, using simple elliptic curves. In contrast to other fiducial-based tracking methods, our method uses a single ellipse to constrain 5 out of 6 degrees of freedom of C-arm pose, along with randomly distributed unknown points in the imaging volume (either naturally present or induced by randomly placed beads or other markers in the image space) from two images/views to completely recover the C-arm pose. Preliminary phantom experiments indicate an average C-arm tracking accuracy of 0.51° and 0.12° STD. The method appears to be sufficiently accurate and appealing for many clinical applications, since it uses a simple elliptic fiducial coupled with patient information and has very minimal interference with the workspace.

Entities:  

Year:  2008        PMID: 26257988      PMCID: PMC4527545          DOI: 10.1109/CVPRW.2008.4563029

Source DB:  PubMed          Journal:  Conf Comput Vis Pattern Recognit Workshops        ISSN: 2160-7508


  5 in total

1.  Fluoroscopy as an imaging means for computer-assisted surgical navigation.

Authors:  R Hofstetter; M Slomczykowski; M Sati; L P Nolte
Journal:  Comput Aided Surg       Date:  1999

2.  A C-arm fluoroscopy-guided progressive cut refinement strategy using a surgical robot.

Authors:  J Yao; R H Taylor; R P Goldberg; R Kumar; A Bzostek; R Van Vorhis; P Kazanzides; A Gueziec
Journal:  Comput Aided Surg       Date:  2000

3.  FTRAC--a robust fluoroscope tracking fiducial.

Authors:  Ameet Kumar Jain; Tabish Mustafa; Yu Zhou; Clif Burdette; Gregory S Chirikjian; Gabor Fichtinger
Journal:  Med Phys       Date:  2005-10       Impact factor: 4.071

4.  Precise robot-assisted guide positioning for distal locking of intramedullary nails.

Authors:  Ziv Yaniv; Leo Joskowicz
Journal:  IEEE Trans Med Imaging       Date:  2005-05       Impact factor: 10.048

5.  C-arm tracking and reconstruction without an external tracker.

Authors:  Ameet Jain; Gabor Fichtinger
Journal:  Med Image Comput Comput Assist Interv       Date:  2006
  5 in total
  4 in total

1.  C-arm Pose Estimation Using a Set of Coplanar Ellipses in Correspondence.

Authors:  Maria S Ayad; Junghoon Lee; Anton Deguet; Everette C Burdette; Jerry L Prince
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2010-04-14

2.  A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging.

Authors:  Shahram Amiri; David R Wilson; Bassam A Masri; Carolyn Anglin
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-12-10       Impact factor: 2.924

3.  C-arm angle measurement with accelerometer for brachytherapy: an accuracy study.

Authors:  Thomas Wolff; Andras Lasso; Markus Eblenkamp; Erich Wintermantel; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-07-03       Impact factor: 2.924

4.  Prostate brachytherapy seed localization using a mobile c-arm without tracking.

Authors:  Maria S Ayad; Junghoon Lee; Jerry L Prince; Gabor Fichtinger
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-03-13
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.