Literature DB >> 11870837

High temporal resolution phase contrast MRI with multiecho acquisitions.

Richard B Thompson1, Elliot R McVeigh.   

Abstract

Velocity imaging with phase contrast (PC) MRI is a noninvasive tool for quantitative blood flow measurement in vivo. A shortcoming of conventional PC imaging is the reduction in temporal resolution as compared to the corresponding magnitude imaging. For the measurement of velocity in a single direction, the temporal resolution is halved because one must acquire two differentially flow-encoded images for every PC image frame to subtract out non-velocity-related image phase information. In this study, a high temporal resolution PC technique which retains both the spatial resolution and breath-hold length of conventional magnitude imaging is presented. Improvement by a factor of 2 in the temporal resolution was achieved by acquiring the differentially flow-encoded images in separate breath-holds rather than interleaved within a single breath-hold. Additionally, a multiecho readout was incorporated into the PC experiment to acquire more views per unit time than is possible with the single gradient-echo technique. A total improvement in temporal resolution by approximately 5 times over conventional PC imaging was achieved. A complete set of images containing velocity data in all three directions was acquired in four breath-holds, with a temporal resolution of 11.2 ms and an in-plane spatial resolution of 2 mm x 2 mm.

Mesh:

Year:  2002        PMID: 11870837      PMCID: PMC2396327          DOI: 10.1002/mrm.10079

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  32 in total

1.  Pitfalls in Doppler evaluation of diastolic function: insights from 3-dimensional magnetic resonance imaging.

Authors:  A Fyrenius; L Wigström; A F Bolger; T Ebbers; K P Ohman; M Karlsson; B Wranne; J Engvall
Journal:  J Am Soc Echocardiogr       Date:  1999-10       Impact factor: 5.251

2.  Multi-echo segmented k-space imaging: an optimized hybrid sequence for ultrafast cardiac imaging.

Authors:  S B Reeder; E Atalar; A Z Faranesh; E R McVeigh
Journal:  Magn Reson Med       Date:  1999-02       Impact factor: 4.668

3.  Quantification of mitral regurgitation with MR phase-velocity mapping using a control volume method.

Authors:  G P Chatzimavroudis; J N Oshinski; R I Pettigrew; P G Walker; R H Franch; A P Yoganathan
Journal:  J Magn Reson Imaging       Date:  1998 May-Jun       Impact factor: 4.813

4.  Flow quantitation with echo-planar phase-contrast velocity mapping: in vitro and in vivo evaluation.

Authors:  J F Debatin; D A Leung; S Wildermuth; R Botnar; J Felblinger; G C McKinnon
Journal:  J Magn Reson Imaging       Date:  1995 Nov-Dec       Impact factor: 4.813

5.  Gradient moment smoothing: a new flow compensation technique for multi-shot echo-planar imaging.

Authors:  G S Slavin; S J Riederer
Journal:  Magn Reson Med       Date:  1997-09       Impact factor: 4.668

6.  Coronary flow reserve: noninvasive measurement in humans with breath-hold velocity-encoded cine MR imaging.

Authors:  H Sakuma; L M Blake; T M Amidon; M O'Sullivan; D H Szolar; A P Furber; M A Bernstein; T K Foo; C B Higgins
Journal:  Radiology       Date:  1996-03       Impact factor: 11.105

7.  Using cardiac phase to order reconstruction (CAPTOR): a method to improve diastolic images.

Authors:  J A Feinstein; F H Epstein; A E Arai; T K Foo; M R Hartley; R S Balaban; S D Wolff
Journal:  J Magn Reson Imaging       Date:  1997 Sep-Oct       Impact factor: 4.813

8.  Restrictive left ventricular filling patterns are predictive of diastolic ventricular interaction in chronic heart failure.

Authors:  J J Atherton; T D Moore; H L Thomson; M P Frenneaux
Journal:  J Am Coll Cardiol       Date:  1998-02       Impact factor: 24.094

9.  Accuracy of echocardiography for detection of aortic arch obstruction after stage I Norwood procedure.

Authors:  A Fraisse; S D Colan; R A Jonas; K Gauvreau; T Geva
Journal:  Am Heart J       Date:  1998-02       Impact factor: 4.749

10.  Predictive medicine: computational techniques in therapeutic decision-making.

Authors:  C A Taylor; M T Draney; J P Ku; D Parker; B N Steele; K Wang; C K Zarins
Journal:  Comput Aided Surg       Date:  1999
View more
  11 in total

1.  Fast measurement of intracardiac pressure differences with 2D breath-hold phase-contrast MRI.

Authors:  Richard B Thompson; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-06       Impact factor: 4.668

Review 2.  Cardiovascular interventional magnetic resonance imaging.

Authors:  Robert J Lederman
Journal:  Circulation       Date:  2005-11-08       Impact factor: 29.690

3.  Real-time magnetic resonance-guided endovascular repair of experimental abdominal aortic aneurysm in swine.

Authors:  Venkatesh K Raman; Parag V Karmarkar; Michael A Guttman; Alexander J Dick; Dana C Peters; Cengizhan Ozturk; Breno S S Pessanha; Richard B Thompson; Amish N Raval; Ranil DeSilva; Ronnier J Aviles; Ergin Atalar; Elliot R McVeigh; Robert J Lederman
Journal:  J Am Coll Cardiol       Date:  2005-06-21       Impact factor: 24.094

4.  Estimating Motion From MRI Data.

Authors:  Cengizhan Ozturk; J Andrew Derbyshire; Elliot R McVeigh
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2003-10       Impact factor: 10.961

5.  Importance of dynamic aortic evaluation in planning TEVAR.

Authors:  Guido H W van Bogerijen; Joost A van Herwaarden; Michele Conti; Ferdinando Auricchio; Vincenzo Rampoldi; Santi Trimarchi; Frans L Moll
Journal:  Ann Cardiothorac Surg       Date:  2014-05

6.  Assessment of the compliance with minimum acceptable technical parameters proposed by PI-RADS v2 guidelines in multiparametric prostate MRI acquisition in tertiary referral hospitals in the Republic of Turkey.

Authors:  Mehmet Coşkun; Ali Fırat Sarp; Şebnem Karasu; Mustafa Fazıl Gelal; Barış Türkbey
Journal:  Diagn Interv Radiol       Date:  2019-11       Impact factor: 2.630

7.  Free-breathing phase contrast MRI with near 100% respiratory navigator efficiency using k-space-dependent respiratory gating.

Authors:  Mehmet Akçakaya; Praveen Gulaka; Tamer A Basha; Long H Ngo; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2013-07-30       Impact factor: 4.668

8.  Using independent component analysis to remove artifact from electroencephalographic measured during stuttered speech.

Authors:  Y Tran; A Craig; P Boord; D Craig
Journal:  Med Biol Eng Comput       Date:  2004-09       Impact factor: 2.602

9.  Phase-contrast MRI with hybrid one and two-sided flow-encoding and velocity spectrum separation.

Authors:  Da Wang; Jiaxin Shao; Daniel B Ennis; Peng Hu
Journal:  Magn Reson Med       Date:  2016-08-09       Impact factor: 4.668

10.  Acceleration of tissue phase mapping by k-t BLAST: a detailed analysis of the influence of k-t-BLAST for the quantification of myocardial motion at 3T.

Authors:  Anja Lutz; Axel Bornstedt; Robert Manzke; Patrick Etyngier; G Ulrich Nienhaus; Volker Rasche
Journal:  J Cardiovasc Magn Reson       Date:  2011-01-11       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.