Literature DB >> 16255422

Evaluation of achievable registration accuracy of the femur during minimally invasive total hip replacement.

F C Popescu1, M Viceconti, F Traina, A Toni.   

Abstract

The aim of the paper was to investigate whether accurate, point-based registration of the intra-operative femur will be achieved within the context of minimally invasive surgery for total hip replacement. Computer tomography images, collected for pre-operative planning purposes, were used to simulate the intra-operative registration procedure using algorithms for various levels of measurement noise, different small areas of the femur available to the surgeon, and a limited number of collected data points (20-60). This helped with the choice of design variables to perform in vitro registration on a plastic bone model to validate the procedure, which included a multistart algorithm developed for intra-operative registration. The algorithm minimised the distance between the measured and image-derived surfaces and was able to cope with the presence of multiple local minima given sufficient computational effort, even with realistically large measurement noise. It was found that, if a small patch of the femur was used, accessible by a needle that could at times penetrate thin layers of soft tissue, errors in the order of 1.0 mm in translation and 0.5 degrees in rotation were achievable.

Mesh:

Year:  2005        PMID: 16255422     DOI: 10.1007/bf02344721

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  18 in total

Review 1.  A survey of medical image registration.

Authors:  J B Maintz; M A Viergever
Journal:  Med Image Anal       Date:  1998-03       Impact factor: 8.545

2.  An algorithmic overview of surface registration techniques for medical imaging.

Authors:  M A Audette; F P Ferrie; T M Peters
Journal:  Med Image Anal       Date:  2000-09       Impact factor: 8.545

3.  Rigid registration of 3-D ultrasound with MR images: a new approach combining intensity and gradient information.

Authors:  A Roche; X Pennec; G Malandain; N Ayache
Journal:  IEEE Trans Med Imaging       Date:  2001-10       Impact factor: 10.048

4.  Restricted surface matching--numerical optimization and technical evaluation.

Authors:  R Bächler; H Bunke; L P Nolte
Journal:  Comput Aided Surg       Date:  2001

5.  White paper: challenges and opportunities in computer-assisted interventions January 2001.

Authors:  R Shahidi; L Clarke; R D Bucholz; H Fuchs; R Kikinis; R A Robb; M W Vannier
Journal:  Comput Aided Surg       Date:  2001

6.  Accuracy evaluation of surface-based registration methods in a computer navigation system for hip surgery performed through a posterolateral approach.

Authors:  N Sugano; T Sasama; Y Sato; Y Nakajima; T Nishii; K Yonenobu; S Tamura; T Ochi
Journal:  Comput Aided Surg       Date:  2001

7.  A new method to compare planned and achieved position of an orthopaedic implant.

Authors:  Florin Popescu; Marco Viceconti; Erika Grazi; Angelo Cappello
Journal:  Comput Methods Programs Biomed       Date:  2003-06       Impact factor: 5.428

8.  Genetic algorithms for a robust 3-D MR-CT registration.

Authors:  J M Rouet; J J Jacq; C Roux
Journal:  IEEE Trans Inf Technol Biomed       Date:  2000-06

9.  Surface-based registration of CT images to physical space for image-guided surgery of the spine: a sensitivity study.

Authors:  J L Herring; B M Dawant; C R Maurer; D M Muratore; R L Galloway; J M Fitzpatrick
Journal:  IEEE Trans Med Imaging       Date:  1998-10       Impact factor: 10.048

10.  Techniques for fast and accurate intrasurgical registration.

Authors:  D A Simon; M Hebert; T Kanade
Journal:  J Image Guid Surg       Date:  1995
View more
  3 in total

1.  Anatomical evaluation of CT-MRI combined femoral model.

Authors:  Yeon S Lee; Jong K Seon; Vladimir I Shin; Gyu-Ha Kim; Moongu Jeon
Journal:  Biomed Eng Online       Date:  2008-01-30       Impact factor: 2.819

2.  A quasi-brittle continuum damage finite element model of the human proximal femur based on element deletion.

Authors:  Ridha Hambli
Journal:  Med Biol Eng Comput       Date:  2012-11-21       Impact factor: 2.602

3.  Prostate positioning errors associated with two automatic registration based image guidance strategies.

Authors:  D Ryan; C Rivest; Terence A Riauka; Albert D Murtha; B Gino Fallone
Journal:  J Appl Clin Med Phys       Date:  2009-10-15       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.