A Roche1, X Pennec, G Malandain, N Ayache.
Abstract
We present a new image-based technique to rigidly register intraoperative three-dimensional ultrasound (US) with preoperative magnetic resonance (MR) images. Automatic registration is achieved by maximization of a similarity measure which generalizes the correlation ratio, and whose novelty is to incorporate multivariate information from the MR data (intensity and gradient). In addition, the similarity measure is built upon a robust intensity-based distance measure, which makes it possible to handle a variety of US artifacts. A cross-validation study has been carried out using a number of phantom and clinical data. This indicates that the method is quite robust and that the worst registration errors are of the order of the MR image resolution.Mesh:
Year: 2001 PMID: 11686439 DOI: 10.1109/42.959301
Source DB: PubMed Journal: IEEE Trans Med Imaging ISSN: 0278-0062 Impact factor: 10.048