Techniques for fast and accurate intrasurgical registration.

D A Simon1, M Hebert, T Kanade.   

Abstract

The goal of intrasurgical registration is to establish a common reference frame between presurgical and intrasurgical three-dimensional data sets that correspond to the same anatomy. This paper presents two novel techniques that have application to this problem, high-speed pose tracking and intrasurgical data selection. In the first part of this paper, we describe an approach for tracking the pose of arbitrarily shaped rigid objects at rates up to 10 Hz. Static accuracies on the order of 1 mm in translation and 1 degree in rotation have been achieved. We have demonstrated the technique on a human face using a high-speed VLSI range sensor; however, the technique is independent of the sensor used or the anatomy tracked. In the second part of this paper, we describe a general purpose approach for selecting near-optimal intrasurgical registration data. Because of the high costs of acquisition of intrasurgical data, our goal is to minimize the amount of data acquired while ensuring registration accuracy. We synthesize near-optimal intrasurgical data sets, based on an analysis of differential surface properties of presurgical data. We demonstrate, using data from a human femur, that discrete-point data sets selected using our method are superior to those selected by human experts in terms of the resulting pose-refinement accuracy.

Entities:  

Mesh:

Year:  1995        PMID: 9079423     DOI: 10.1002/(SICI)1522-712X(1995)1:1<17::AID-IGS4>3.0.CO;2-P

Source DB:  PubMed          Journal:  J Image Guid Surg        ISSN: 1078-7844


  4 in total

1.  Evaluation of achievable registration accuracy of the femur during minimally invasive total hip replacement.

Authors:  F C Popescu; M Viceconti; F Traina; A Toni
Journal:  Med Biol Eng Comput       Date:  2005-07       Impact factor: 2.602

2.  The effect of elbow joint centre displacement on force generation and neural excitation.

Authors:  Emer P Doheny; Madeleine M Lowery; Mark J O'Malley; David P Fitzpatrick
Journal:  Med Biol Eng Comput       Date:  2009-04-28       Impact factor: 2.602

3.  Minimally invasive 3D data registration in computer and robot assisted total knee arthroplasty.

Authors:  P F La Palombara; M Fadda; S Martelli; M Marcacci
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

4.  Numerical optimization of alignment reproducibility for customizable surgical guides.

Authors:  Thomas Kroes; Edward Valstar; Elmar Eisemann
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-11       Impact factor: 2.924