Non-invasive half millimetre 32 detector row computed tomography angiography accurately excludes significant stenoses in patients with advanced coronary artery disease and high calcium scores.

M A S Cordeiro1, J M Miller, A Schmidt, A C Lardo, B D Rosen, D E Bush, J A Brinker, D A Bluemke, E P Shapiro, J A C Lima.   

Abstract

OBJECTIVE: To show an overall diagnostic accuracy > or = 90% for detection of > or = 50% stenoses by coronary half millimetre 32 detector row computed tomography angiography (32 x 0.5-MDCTA) in patients with advanced coronary artery disease (CAD) and a high likelihood of raised calcium scores.
METHODS: ECG gated 32 x 0.5-MDCTA (32 x 0.5 mm cross sections, 0.35 x 0.35 x 0.35 mm3 isotropic voxels, 400 ms rotation) was performed after injection of iodixanol (120 ml, 320 mg/ml) in 30 consecutive patients (25 men, mean (SD) age 59 (13) years, body mass index 26.2 (4.9) kg/m2). Native arteries, including > or = 1.5 mm branches, and bypass grafts were screened for > or = 50% stenoses. Stents were excluded. Conventional coronary angiography (performed 18 (12) days before 32 x 0.5-MDCTA) was analysed by quantitative coronary angiography.
RESULTS: Median Agatston calcium score was 510 (range 3-5066). Sensitivity, specificity, and positive and negative predictive values for detection of > or = 50% stenoses in native arteries were 76% (29 of 38), 94% (190 of 202), 71% (29 of 41), and 96% (190 of 199), respectively. Overall diagnostic accuracy was 91% (219 of 240). Due to the following artefacts 20% (69 of 352) of the vessels were excluded: motion, noise, and low contrast enhancement isolated or in combination (45 of 69 (65%)); image distortion by implantable cardioverter-defibrillator or pacemaker leads (18 of 69 (26%)); and blooming secondary to severe calcification (6 of 69 (9%)).
CONCLUSIONS: Coronary 32 x 0.5-MDCTA accurately excludes > or = 50% stenoses in patients with advanced CAD and high calcium scores with an overall diagnostic accuracy of 91%.

Entities:  

Mesh:

Year:  2005        PMID: 16251224      PMCID: PMC1860949          DOI: 10.1136/hrt.2005.074336

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  17 in total

1.  Coronary angiography with multi-slice computed tomography.

Authors:  K Nieman; M Oudkerk; B J Rensing; P van Ooijen; A Munne; R J van Geuns; P J de Feyter
Journal:  Lancet       Date:  2001-02-24       Impact factor: 79.321

2.  Electromagnetic interference in patients with implanted pacemakers or cardioverter-defibrillators.

Authors:  M Niehaus; J Tebbenjohanns
Journal:  Heart       Date:  2001-09       Impact factor: 5.994

3.  CT angiography in highly calcified arteries: 2D manual vs. modified automated 3D approach to identify coronary stenoses.

Authors:  Marco A S Cordeiro; Albert C Lardo; Marcelo S V Brito; Miguel A Rosário Neto; Maria H A Siqueira; José R Parga; Luiz F Avila; José A F Ramires; João A C Lima; Carlos E Rochitte
Journal:  Int J Cardiovasc Imaging       Date:  2006-03-15       Impact factor: 2.357

4.  Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound.

Authors:  Alexander W Leber; Andreas Knez; Franz von Ziegler; Alexander Becker; Konstantin Nikolaou; Stephan Paul; Bernd Wintersperger; Maximilian Reiser; Christoph R Becker; Gerhard Steinbeck; Peter Boekstegers
Journal:  J Am Coll Cardiol       Date:  2005-07-05       Impact factor: 24.094

Review 5.  Electron beam computed tomographic coronary calcium scanning: a review and guidelines for use in asymptomatic persons.

Authors:  J A Rumberger; B H Brundage; D J Rader; G Kondos
Journal:  Mayo Clin Proc       Date:  1999-03       Impact factor: 7.616

6.  Accuracy of MSCT coronary angiography with 64-slice technology: first experience.

Authors:  Sebastian Leschka; Hatem Alkadhi; André Plass; Lotus Desbiolles; Jürg Grünenfelder; Borut Marincek; Simon Wildermuth
Journal:  Eur Heart J       Date:  2005-04-19       Impact factor: 29.983

7.  Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography.

Authors:  Koen Nieman; Filippo Cademartiri; Pedro A Lemos; Rolf Raaijmakers; Peter M T Pattynama; Pim J de Feyter
Journal:  Circulation       Date:  2002-10-15       Impact factor: 29.690

8.  Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography.

Authors:  Gilbert L Raff; Michael J Gallagher; William W O'Neill; James A Goldstein
Journal:  J Am Coll Cardiol       Date:  2005-08-02       Impact factor: 24.094

Review 9.  Coronary calcium measurements: effect of CT scanner type and calcium measure on rescan reproducibility--MESA study.

Authors:  Robert C Detrano; Melissa Anderson; Jennifer Nelson; Nathan D Wong; J Jeffrey Carr; Michael McNitt-Gray; Diane E Bild
Journal:  Radiology       Date:  2005-06-21       Impact factor: 11.105

10.  Comparative validation of quantitative coronary angiography systems. Results and implications from a multicenter study using a standardized approach.

Authors:  D Keane; J Haase; C J Slager; E Montauban van Swijndregt; K G Lehmann; Y Ozaki; C di Mario; R Kirkeeide; P W Serruys
Journal:  Circulation       Date:  1995-04-15       Impact factor: 29.690

View more
  13 in total

1.  Computed tomographic coronary angiography: how many slices do you need?

Authors:  C Peebles
Journal:  Heart       Date:  2006-05       Impact factor: 5.994

Review 2.  Comprehensive cardiac CT study: evaluation of coronary arteries, left ventricular function, and myocardial perfusion--is it possible?

Authors:  Ricardo C Cury; Koen Nieman; Michael D Shapiro; Khurram Nasir; Roberto C Cury; Thomas J Brady
Journal:  J Nucl Cardiol       Date:  2007-04       Impact factor: 5.952

3.  Quantitative parameters to compare image quality of non-invasive coronary angiography with 16-slice, 64-slice and dual-source computed tomography.

Authors:  Christof Burgstahler; Anja Reimann; Harald Brodoefel; Ulrike Daferner; Tina Herberts; Ilias Tsiflikas; Christoph Thomas; Tanja Drosch; Stephen Schroeder; Martin Heuschmid
Journal:  Eur Radiol       Date:  2008-10-25       Impact factor: 5.315

4.  Image quality on dual-source computed-tomographic coronary angiography.

Authors:  Johannes Rixe; Andreas Rolf; Guido Conradi; Albrecht Elsaesser; Helge Moellmann; Holger M Nef; Georg Bachmann; Christian W Hamm; Thorsten Dill
Journal:  Eur Radiol       Date:  2008-04-17       Impact factor: 5.315

5.  Progress in atherosclerotic plaque imaging.

Authors:  Giulia Soloperto; Sergio Casciaro
Journal:  World J Radiol       Date:  2012-08-28

6.  Diagnostic accuracy of computed tomography coronary angiography according to pre-test probability of coronary artery disease and severity of coronary arterial calcification. The CORE-64 (Coronary Artery Evaluation Using 64-Row Multidetector Computed Tomography Angiography) International Multicenter Study.

Authors:  Armin Arbab-Zadeh; Julie M Miller; Carlos E Rochitte; Marc Dewey; Hiroyuki Niinuma; Ilan Gottlieb; Narinder Paul; Melvin E Clouse; Edward P Shapiro; John Hoe; Albert C Lardo; David E Bush; Albert de Roos; Christopher Cox; Jeffrey Brinker; Joăo A C Lima
Journal:  J Am Coll Cardiol       Date:  2012-01-24       Impact factor: 24.094

7.  The comparison of high and standard definition computed tomography techniques regarding coronary artery imaging.

Authors:  Aktas Aykut; Degirmenci Bumin; Yilmaz Omer; Kayan Mustafa; Cetin Meltem; Celik Orhan; Unlu Nisa; Orhan Hikmet; Demirtas Hakan; Koroglu Mert
Journal:  Afr Health Sci       Date:  2015-09       Impact factor: 0.927

8.  Patient characteristics as predictors of image quality and diagnostic accuracy of MDCT compared with conventional coronary angiography for detecting coronary artery stenoses: CORE-64 Multicenter International Trial.

Authors:  Marc Dewey; Andrea L Vavere; Armin Arbab-Zadeh; Julie M Miller; Leonardo Sara; Christopher Cox; Ilan Gottlieb; Kunihiro Yoshioka; Narinder Paul; John Hoe; Albert de Roos; Albert C Lardo; Joao A Lima; Melvin E Clouse
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

9.  Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64.

Authors:  Julie M Miller; Marc Dewey; Andrea L Vavere; Carlos E Rochitte; Hiroyuki Niinuma; Armin Arbab-Zadeh; Narinder Paul; John Hoe; Albert de Roos; Kunihiro Yoshioka; Pedro A Lemos; David E Bush; Albert C Lardo; John Texter; Jeffery Brinker; Christopher Cox; Melvin E Clouse; João A C Lima
Journal:  Eur Radiol       Date:  2008-11-08       Impact factor: 5.315

10.  Comparison of 3D free-breathing coronary MR angiography and 64-MDCT angiography for detection of coronary stenosis in patients with high calcium scores.

Authors:  Xin Liu; Xihai Zhao; Jie Huang; Christopher J Francois; David Tuite; Xiaoming Bi; Debiao Li; James C Carr
Journal:  AJR Am J Roentgenol       Date:  2007-12       Impact factor: 3.959

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.