In vivo volumetric analysis of coronary stent using optical coherence tomography with a novel balloon occlusion-flushing catheter: a comparison with intravascular ultrasound.

Yoshiaki Kawase1, Kozo Hoshino, Ryuichi Yoneyama, Jennifer McGregor, Roger J Hajjar, Ik-Kyung Jang, Motoya Hayase.   

Abstract

Optical coherence tomography (OCT) is limited as an intravascular imaging tool because of interference with blood. This study tested a new balloon occlusion-flushing catheter for OCT scanning of stented coronary arteries and compared stent measurements between OCT and intravascular ultrasound (IVUS). Motorized pullback with OCT and IVUS was examined in coronary stents deployed in swine. Quantitative measurements were obtained and compared between both groups. In addition, stent strut thickness was compared among OCT, IVUS and actual measurement. The occlusion catheter successfully provided motorized pullback OCT images in the stented coronary arteries without any complications. There were no differences in calculated lumen volume. However, stent volumes were significantly smaller with OCT than with IVUS (p < 0.05). OCT significantly underestimated the stent strut thickness compared with the actual measurement. Although OCT underestimates the stent strut thickness, motorized pullback OCT imaging with the occlusion catheter can provide appropriate in-stent images in the porcine coronary arteries.

Entities:  

Mesh:

Year:  2005        PMID: 16223637     DOI: 10.1016/j.ultrasmedbio.2005.05.010

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  12 in total

1.  Use of an oxygen-carrying blood substitute to improve intravascular optical coherence tomography imaging.

Authors:  Khiet C Hoang; Ahmad Edris; Jianping Su; David S Mukai; Sari Mahon; Artiom D Petrov; Morton Kern; Chowdhury Ashan; Zhongping Chen; Bruce J Tromberg; Jagat Narula; Matthew Brenner
Journal:  J Biomed Opt       Date:  2009 May-Jun       Impact factor: 3.170

2.  In vivo comparison of lumen dimensions measured by time domain-, and frequency domain-optical coherence tomography, and intravascular ultrasound.

Authors:  Soo-Joong Kim; Hang Lee; Koji Kato; Taishi Yonetsu; Ik-Kyung Jang
Journal:  Int J Cardiovasc Imaging       Date:  2013-01-06       Impact factor: 2.357

3.  Intra-coronary imaging modalities.

Authors:  Paul M Johnson; Jigar Patel; Michael Yeung; Prashant Kaul
Journal:  Curr Treat Options Cardiovasc Med       Date:  2014-05

4.  Ex vivo imaging of human thyroid pathology using integrated optical coherence tomography and optical coherence microscopy.

Authors:  Chao Zhou; Yihong Wang; Aaron D Aguirre; Tsung-Han Tsai; David W Cohen; James L Connolly; James G Fujimoto
Journal:  J Biomed Opt       Date:  2010 Jan-Feb       Impact factor: 3.170

5.  Neuroendovascular optical coherence tomography imaging and histological analysis.

Authors:  Marlon S Mathews; Jianping Su; Esmaeil Heidari; Elad I Levy; Mark E Linskey; Zhongping Chen
Journal:  Neurosurgery       Date:  2011-08       Impact factor: 4.654

6.  Intravascular Photoacoustic Imaging.

Authors:  Bo Wang; Jimmy L Su; Andrei B Karpiouk; Konstantin V Sokolov; Richard W Smalling; Stanislav Y Emelianov
Journal:  IEEE J Quantum Electron       Date:  2010-06-03       Impact factor: 2.318

7.  Computer Vision Techniques for Transcatheter Intervention.

Authors:  Feng Zhao; Xianghua Xie; Matthew Roach
Journal:  IEEE J Transl Eng Health Med       Date:  2015-06-18       Impact factor: 3.316

8.  Estimation of nonlinear mechanical properties of vascular tissues via elastography.

Authors:  Reza Karimi; Ting Zhu; Brett E Bouma; Mohammad R Kaazempur Mofrad
Journal:  Cardiovasc Eng       Date:  2008-12

9.  Quantitative multi-modality imaging analysis of a fully bioresorbable stent: a head-to-head comparison between QCA, IVUS and OCT.

Authors:  Juan Luis Gutiérrez-Chico; Patrick W Serruys; Chrysafios Girasis; Scot Garg; Yoshinobu Onuma; Salvatore Brugaletta; Héctor García-García; Gerrit-Anne van Es; Evelyn Regar
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-26       Impact factor: 2.357

10.  Interstudy reproducibility of the second generation, Fourier domain optical coherence tomography in patients with coronary artery disease and comparison with intravascular ultrasound: a study applying automated contour detection.

Authors:  Z Jamil; G Tearney; N Bruining; K Sihan; G van Soest; J Ligthart; R van Domburg; B Bouma; E Regar
Journal:  Int J Cardiovasc Imaging       Date:  2012-05-26       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.