Literature DB >> 19048372

Estimation of nonlinear mechanical properties of vascular tissues via elastography.

Reza Karimi1, Ting Zhu, Brett E Bouma, Mohammad R Kaazempur Mofrad.   

Abstract

A new method is proposed for estimation of nonlinear elastic properties of soft tissues. The proposed approach involves a combination of nonlinear finite element methods with a genetic algorithm for estimating tissue stiffness profile. A multipoint scheme is introduced that satisfies the uniqueness condition, improves the estimation performance, and reduces the sensitivity to image noise. The utility of the proposed techniques is demonstrated using optical coherence tomography (OCT) images. The approach is, however, applicable to other imaging systems and modalities, as well, provided a reliable image registration scheme. The proposed algorithm is applied to realistic (2D) and idealized (3D) arterial plaque models, and proves promising for the estimation of intra-plaque distribution of nonlinear material properties.

Entities:  

Mesh:

Year:  2008        PMID: 19048372      PMCID: PMC2703584          DOI: 10.1007/s10558-008-9061-0

Source DB:  PubMed          Journal:  Cardiovasc Eng        ISSN: 1567-8822


  30 in total

1.  Evaluation of an iterative reconstruction method for quantitative elastography.

Authors:  M M Doyley; P M Meaney; J C Bamber
Journal:  Phys Med Biol       Date:  2000-06       Impact factor: 3.609

2.  Quantification of vessel wall cyclic strain using cine phase contrast magnetic resonance imaging.

Authors:  Mary T Draney; Robert J Herfkens; Thomas J R Hughes; Norbert J Pelc; Kristin L Wedding; Christopher K Zarins; Charles A Taylor
Journal:  Ann Biomed Eng       Date:  2002-09       Impact factor: 3.934

3.  Circumferential stress and matrix metalloproteinase 1 in human coronary atherosclerosis. Implications for plaque rupture.

Authors:  R T Lee; F J Schoen; H M Loree; M W Lark; P Libby
Journal:  Arterioscler Thromb Vasc Biol       Date:  1996-08       Impact factor: 8.311

Review 4.  Optical coherence tomography for imaging the vulnerable plaque.

Authors:  Guillermo J Tearney; Ik-Kyung Jang; Brett E Bouma
Journal:  J Biomed Opt       Date:  2006 Mar-Apr       Impact factor: 3.170

5.  Elastography: a quantitative method for imaging the elasticity of biological tissues.

Authors:  J Ophir; I Céspedes; H Ponnekanti; Y Yazdi; X Li
Journal:  Ultrason Imaging       Date:  1991-04       Impact factor: 1.578

6.  In vivo volumetric analysis of coronary stent using optical coherence tomography with a novel balloon occlusion-flushing catheter: a comparison with intravascular ultrasound.

Authors:  Yoshiaki Kawase; Kozo Hoshino; Ryuichi Yoneyama; Jennifer McGregor; Roger J Hajjar; Ik-Kyung Jang; Motoya Hayase
Journal:  Ultrasound Med Biol       Date:  2005-10       Impact factor: 2.998

Review 7.  Intravascular palpography for high-risk vulnerable plaque assessment.

Authors:  Johannes A Schaar; Chris L de Korte; Frits Mastik; Radj Baldewsing; Evelyn Regar; Pim de Feyter; Cornelis J Slager; Anton F W van der Steen; Patrick W Serruys
Journal:  Herz       Date:  2003-09       Impact factor: 1.443

8.  Computational structural analysis based on intravascular ultrasound imaging before in vitro angioplasty: prediction of plaque fracture locations.

Authors:  R T Lee; H M Loree; G C Cheng; E H Lieberman; N Jaramillo; F J Schoen
Journal:  J Am Coll Cardiol       Date:  1993-03-01       Impact factor: 24.094

9.  Effects of fibrous cap thickness on peak circumferential stress in model atherosclerotic vessels.

Authors:  H M Loree; R D Kamm; R G Stringfellow; R T Lee
Journal:  Circ Res       Date:  1992-10       Impact factor: 17.367

10.  Incidence of high-strain patterns in human coronary arteries: assessment with three-dimensional intravascular palpography and correlation with clinical presentation.

Authors:  Johannes A Schaar; Evelyn Regar; Frits Mastik; Eugene P McFadden; Francesco Saia; Clemens Disco; Chris L de Korte; Pim J de Feyter; Antonius F W van der Steen; Patrick W Serruys
Journal:  Circulation       Date:  2004-05-24       Impact factor: 29.690

View more
  13 in total

1.  Investigating in vivo airway wall mechanics during tidal breathing with optical coherence tomography.

Authors:  Claire Robertson; Sang-Won Lee; Yeh-Chan Ahn; Sari Mahon; Zhongping Chen; Matthew Brenner; Steven C George
Journal:  J Biomed Opt       Date:  2011-10       Impact factor: 3.170

Review 2.  Optical coherence elastography - OCT at work in tissue biomechanics [Invited].

Authors:  Kirill V Larin; David D Sampson
Journal:  Biomed Opt Express       Date:  2017-01-27       Impact factor: 3.732

3.  Nonlinear characterization of elasticity using quantitative optical coherence elastography.

Authors:  Yi Qiu; Farzana R Zaki; Namas Chandra; Shawn A Chester; Xuan Liu
Journal:  Biomed Opt Express       Date:  2016-10-26       Impact factor: 3.732

4.  DYNAMIC OPTICAL COHERENCE ELASTOGRAPHY: A REVIEW.

Authors:  Xing Liang; Vasilica Crecea; Stephen A Boppart
Journal:  J Innov Opt Health Sci       Date:  2010-10

5.  Carotid atheroma rupture observed in vivo and FSI-predicted stress distribution based on pre-rupture imaging.

Authors:  Joseph R Leach; Vitaliy L Rayz; Bruno Soares; Max Wintermark; Mohammad R K Mofrad; David Saloner
Journal:  Ann Biomed Eng       Date:  2010-03-16       Impact factor: 3.934

6.  On the potential of a new IVUS elasticity modulus imaging approach for detecting vulnerable atherosclerotic coronary plaques: in vitro vessel phantom study.

Authors:  Simon Le Floc'h; Guy Cloutier; Gérard Finet; Philippe Tracqui; Roderic I Pettigrew; Jacques Ohayon
Journal:  Phys Med Biol       Date:  2010-09-08       Impact factor: 3.609

7.  An inverse method for mechanical characterization of heterogeneous diseased arteries using intravascular imaging.

Authors:  Bharath Narayanan; Max L Olender; David Marlevi; Elazer R Edelman; Farhad R Nezami
Journal:  Sci Rep       Date:  2021-11-18       Impact factor: 4.379

8.  Methods for robust in vivo strain estimation in the carotid artery.

Authors:  M McCormick; T Varghese; X Wang; C Mitchell; M A Kliewer; R J Dempsey
Journal:  Phys Med Biol       Date:  2012-10-18       Impact factor: 3.609

9.  Magnetic resonance elastography: Inversions in bounded media.

Authors:  Arunark Kolipaka; Kiaran P McGee; Armando Manduca; Anthony J Romano; Kevin J Glaser; Philip A Araoz; Richard L Ehman
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

10.  Influence of material property variability on the mechanical behaviour of carotid atherosclerotic plaques: a 3D fluid-structure interaction analysis.

Authors:  Jianmin Yuan; Zhongzhao Teng; Jiaxuan Feng; Yongxue Zhang; Adam J Brown; Jonathan H Gillard; Zaiping Jing; Qingsheng Lu
Journal:  Int J Numer Method Biomed Eng       Date:  2015-05-28       Impact factor: 2.747

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.