Literature DB >> 27170893

Computer Vision Techniques for Transcatheter Intervention.

Feng Zhao, Xianghua Xie, Matthew Roach.   

Abstract

Minimally invasive transcatheter technologies have demonstrated substantial promise for the diagnosis and the treatment of cardiovascular diseases. For example, transcatheter aortic valve implantation is an alternative to aortic valve replacement for the treatment of severe aortic stenosis, and transcatheter atrial fibrillation ablation is widely used for the treatment and the cure of atrial fibrillation. In addition, catheter-based intravascular ultrasound and optical coherence tomography imaging of coronary arteries provides important information about the coronary lumen, wall, and plaque characteristics. Qualitative and quantitative analysis of these cross-sectional image data will be beneficial to the evaluation and the treatment of coronary artery diseases such as atherosclerosis. In all the phases (preoperative, intraoperative, and postoperative) during the transcatheter intervention procedure, computer vision techniques (e.g., image segmentation and motion tracking) have been largely applied in the field to accomplish tasks like annulus measurement, valve selection, catheter placement control, and vessel centerline extraction. This provides beneficial guidance for the clinicians in surgical planning, disease diagnosis, and treatment assessment. In this paper, we present a systematical review on these state-of-the-art methods. We aim to give a comprehensive overview for researchers in the area of computer vision on the subject of transcatheter intervention. Research in medical computing is multi-disciplinary due to its nature, and hence, it is important to understand the application domain, clinical background, and imaging modality, so that methods and quantitative measurements derived from analyzing the imaging data are appropriate and meaningful. We thus provide an overview on the background information of the transcatheter intervention procedures, as well as a review of the computer vision techniques and methodologies applied in this area.

Entities:  

Keywords:  IVUS; Image processing; OCT; TAFA; TAVI; TMVR; TPVR; TTVI; medical imaging; reconstruction; registration; segmentation; transcatheter intervention

Year:  2015        PMID: 27170893      PMCID: PMC4848047          DOI: 10.1109/JTEHM.2015.2446988

Source DB:  PubMed          Journal:  IEEE J Transl Eng Health Med        ISSN: 2168-2372            Impact factor:   3.316


  150 in total

1.  Segmentation of 3D intravascular ultrasonic images based on a random field model.

Authors:  C Haas; H Ermert; S Holt; P Grewe; A Machraoui; J Barmeyer
Journal:  Ultrasound Med Biol       Date:  2000-02       Impact factor: 2.998

2.  Reconstruction of coronary arteries from a single rotational X-ray projection sequence.

Authors:  Christophe Blondel; Grégoire Malandain; Régis Vaillant; Nicholas Ayache
Journal:  IEEE Trans Med Imaging       Date:  2006-05       Impact factor: 10.048

3.  Percutaneous aortic valve replacement for severe aortic regurgitation in degenerated bioprosthesis: the first valve in valve procedure using the Corevalve Revalving system.

Authors:  Peter Wenaweser; Lutz Buellesfeld; Ulrich Gerckens; Eberhard Grube
Journal:  Catheter Cardiovasc Interv       Date:  2007-11-01       Impact factor: 2.692

4.  Integrated segmentation and interpolation of sparse data.

Authors:  Adeline Paiement; Majid Mirmehdi; Xianghua Xie; Mark C K Hamilton
Journal:  IEEE Trans Image Process       Date:  2013-10-23       Impact factor: 10.856

5.  Automatic model-based segmentation of the heart in CT images.

Authors:  Olivier Ecabert; Jochen Peters; Hauke Schramm; Cristian Lorenz; Jens von Berg; Matthew J Walker; Mani Vembar; Mark E Olszewski; Krishna Subramanyan; Guy Lavi; Jürgen Weese
Journal:  IEEE Trans Med Imaging       Date:  2008-09       Impact factor: 10.048

Review 6.  Percutaneous Edwards SAPIEN valve implantation in the tricuspid position: case report and review of literature.

Authors:  Elke S Hoendermis; Yvonne L Douglas; Ad F M van den Heuvel
Journal:  EuroIntervention       Date:  2012-09       Impact factor: 6.534

7.  Cardiac three-dimensional magnetic resonance imaging and fluoroscopy merging: a new approach for electroanatomic mapping to assist catheter ablation.

Authors:  Joris Ector; Stijn De Buck; Jef Adams; Steven Dymarkowski; Jan Bogaert; Frederik Maes; Hein Heidbüchel
Journal:  Circulation       Date:  2005-12-05       Impact factor: 29.690

8.  Thirty-day results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: A European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve.

Authors:  Martyn Thomas; Gerhard Schymik; Thomas Walther; Dominique Himbert; Thierry Lefèvre; Hendrik Treede; Holger Eggebrecht; Paolo Rubino; Iassen Michev; Rüdiger Lange; William N Anderson; Olaf Wendler
Journal:  Circulation       Date:  2010-06-21       Impact factor: 29.690

9.  Percutaneous insertion of the pulmonary valve.

Authors:  Philipp Bonhoeffer; Younes Boudjemline; Shakeel A Qureshi; Jerome Le Bidois; Laurence Iserin; Philippe Acar; Jacques Merckx; Jean Kachaner; Daniel Sidi
Journal:  J Am Coll Cardiol       Date:  2002-05-15       Impact factor: 24.094

10.  Coronary vein extraction in MSCT volumes using minimum cost path and geometrical moments.

Authors:  Marie-Paule Garcia; Jérôme Velut; Dominique Boulmier; Christophe Leclercq; Mireille Garreau; Pascal Haigron; Christine Toumoulin
Journal:  IEEE J Biomed Health Inform       Date:  2013-03       Impact factor: 5.772

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.