Literature DB >> 24643433

Intra-coronary imaging modalities.

Paul M Johnson1, Jigar Patel, Michael Yeung, Prashant Kaul.   

Abstract

OPINION STATEMENT: The use of intracoronary imaging modalities has seen a significant increase over the past decade, as both imaging quality and delivery systems have improved. Generally accepted best practice indications for using intracoronary imaging include assessment of lesion characteristics prior to stent placement, optimization of stent placement with respect to appropriate sizing, adequate apposition, and expansion and exclusion of edge dissection. Intracoronary imaging plays a particular role in the setting of contemporary left main and bifurcation stenting. Stent interrogation using intracoronary imaging to exclude mechanical causes in the management of in-stent thrombosis has also become conventional. Current clinical guideline recommendations, however, have lagged behind contemporary practice patterns and the use of intravascular ultrasound only carries a class IIa recommendation in the appropriate clinical setting. We discuss the currently available intracoronary imaging modalities and their applications, including intravascular ultrasound (IVUS) and optical coherence tomography (OCT), and review the data supporting their use.

Entities:  

Year:  2014        PMID: 24643433     DOI: 10.1007/s11936-014-0304-7

Source DB:  PubMed          Journal:  Curr Treat Options Cardiovasc Med        ISSN: 1092-8464


  65 in total

Review 1.  American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents.

Authors:  G S Mintz; S E Nissen; W D Anderson; S R Bailey; R Erbel; P J Fitzgerald; F J Pinto; K Rosenfield; R J Siegel; E M Tuzcu; P G Yock
Journal:  J Am Coll Cardiol       Date:  2001-04       Impact factor: 24.094

2.  Coronary plaque classification with intravascular ultrasound radiofrequency data analysis.

Authors:  Anuja Nair; Barry D Kuban; E Murat Tuzcu; Paul Schoenhagen; Steven E Nissen; D Geoffrey Vince
Journal:  Circulation       Date:  2002-10-22       Impact factor: 29.690

Review 3.  Assessment of intermediate severity coronary lesions in the catheterization laboratory.

Authors:  Jonathan Tobis; Babak Azarbal; Leo Slavin
Journal:  J Am Coll Cardiol       Date:  2007-02-09       Impact factor: 24.094

4.  Intravascular ultrasound-guided true lumen reentry device for recanalization of unilateral chronic total occlusion of iliac arteries: technique and follow-up.

Authors:  Venkataramu N Krishnamurthy; Jonathan L Eliason; Peter K Henke; John E Rectenwald
Journal:  Ann Vasc Surg       Date:  2010-04-02       Impact factor: 1.466

5.  An ultrasonic intracardiac scanner.

Authors:  N Bom; C T Lancée; F C Van Egmond
Journal:  Ultrasonics       Date:  1972-03       Impact factor: 2.890

6.  Small stent size and intimal hyperplasia contribute to restenosis: a volumetric intravascular ultrasound analysis.

Authors:  G R Dussaillant; G S Mintz; A D Pichard; K M Kent; L F Satler; J J Popma; S C Wong; M B Leon
Journal:  J Am Coll Cardiol       Date:  1995-09       Impact factor: 24.094

7.  Lipid-rich plaque and myocardial perfusion after successful stenting in patients with non-ST-segment elevation acute coronary syndrome: an optical coherence tomography study.

Authors:  Atsushi Tanaka; Toshio Imanishi; Hironori Kitabata; Takashi Kubo; Shigeho Takarada; Takashi Tanimoto; Akio Kuroi; Hiroto Tsujioka; Hideyuki Ikejima; Kenichi Komukai; Hideaki Kataiwa; Keishi Okouchi; Manabu Kashiwaghi; Kohei Ishibashi; Hiroki Matsumoto; Kazushi Takemoto; Nobuo Nakamura; Kumiko Hirata; Masato Mizukoshi; Takashi Akasaka
Journal:  Eur Heart J       Date:  2009-04-21       Impact factor: 29.983

8.  Serial Evaluation of Vascular Response After Implantation of a New Sirolimus-Eluting Stent With Bioabsorbable Polymer (MISTENT): an optical coherence tomography and histopathological study.

Authors:  Guilherme F Attizzani; Hiram G Bezerra; Daniel Chamié; Yusuke Fujino; Anna-Maria Spognardi; James R L Stanley; Hirosada Yamamoto; Emile Mehanna; Wei Wang; Wenda C Carlyle; James B McClain; Marco A Costa
Journal:  J Invasive Cardiol       Date:  2012-11       Impact factor: 2.022

9.  The potential clinical utility of intravascular ultrasound guidance in patients undergoing percutaneous coronary intervention with drug-eluting stents.

Authors:  Probal Roy; Daniel H Steinberg; Steven J Sushinsky; Teruo Okabe; Tina L Pinto Slottow; Kimberly Kaneshige; Zhenyi Xue; Lowell F Satler; Kenneth M Kent; William O Suddath; Augusto D Pichard; Neil J Weissman; Joseph Lindsay; Ron Waksman
Journal:  Eur Heart J       Date:  2008-06-11       Impact factor: 29.983

Review 10.  IVUS-based imaging modalities for tissue characterization: similarities and differences.

Authors:  Hector M Garcìa-Garcìa; Bill D Gogas; Patrick W Serruys; Nico Bruining
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-17       Impact factor: 2.357

View more
  2 in total

1.  Intravascular Ultrasound Versus Optical Coherence Tomography for Coronary Artery Imaging - Apples and Oranges?

Authors:  Krishnaraj S Rathod; Stephen M Hamshere; Daniel A Jones; Anthony Mathur
Journal:  Interv Cardiol       Date:  2015-03

Review 2.  Advanced Imaging and Diagnostic Methods in the Assessment of Suspected Ischemic Heart Disease in Women.

Authors:  Joanna M Joly; Vera Bittner
Journal:  Curr Cardiol Rep       Date:  2016-09       Impact factor: 2.931

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.